Finish Nailer
Model NT 65M2
Handling instructions
Note:
Before using this Pneumatic Power Tool, carefully read through
these HANDLING INSTRUCTIONS to ensure efficient, safe operation.
It is recommended that these INSTRUCTIONS be kept readily
available as an important reference when using this power tool.
2
GENERAL OPERATIONAL PRECAUTIONS
1. Operate the power tool safely for correct uses.
Do not use the power tool for uses other than
those specified in this instructions.
2. For safe operation handle the power tool correctly.
Please follow the instructions given in this
instruction manual and correctly handle this tool
so as to ensure safe operation. Never let the tool
be use by children or people who do not know
enough to be able to handle it correctly, or let
it be used by people who cannot operate it
correctly.
3. Confirm the safety of the workshop.
Keep unauthorized people away from the
workshop. Especially children should be kept away.
4. The right parts in the right places.
Do not remove any of the covers or screws. Keep
them in place as they have their functions.
Moreover, because it would be dangerous, never
make modifications to the tool or use it after
making modifications.
5. Check the tool before using it.
Before using the tool, always check that no parts
of it are broken, that all screws are completely
tight, and that no parts are missing or rusty.
6. Excessive work could cause accidents.
Do not make tools and accessories work beyond
their abilities. Excessive work not only damages
the power tool but also is dangerous in itself.
7. Stop operation immediately if abnormalities are
noticed.
Stop operation if you notice abnormalities, or if
the power tool does not work properly; have the
power tool inspected and serviced.
8. Look after the power tool carefully.
If you drop or knock the power tool against things,
the outer frame may be deformed and cracks or
other kinds of damage may occur, so please handle
it with sufficient care. Also, do not scratch or
engrave signs on the power tool. Owing to high
pressure air inside the tool, cracks in the surface
are dangerous.
Never use the power tool if a crack develops or
if air is escaping from a crack.
9. Take good care for a long life.
Always take good care of the power tool and keep
it clean.
10. Inspection at regular intervals is essential for
safety.
Inspect the power tool at regular intervals so that
the power tool can be operated safety and
efficiently at all times.
11. Consult an authorized service center if repair or
parts replacement is necessary.
Ensure that the power tool is serviced by authorized
service center only, and that only genuine
replacement parts are used.
12. Keep the power tool in a proper place.
When not in use, the power tool should be kept
in a dry place out of the reach of children. Put
into the body about 2cc oil through the hose joint
to protect the tool from rust.
13. The exploded assembly drawing on this handling
instructions should be used only for authorized
service center.
PRECAUTIONS ON USING NAILER
1. Safe operation through correct usage
This tool was designed for driving nails into wood
and similar materials. Use it for its intended
purpose only.
2. Make sure air pressure is within the rated range
of air pressure.
Please make sure that the air pressure is within
a range of 4.9 bar – 8.3 bar, and that the air which
is used is clean and dry. If the air pressure is
greater than 8.3 bar, the life of the power tool
will be shortened and dangerous conditions could
develop. Tools shall not be connected to pressure
which potentially exceeds 14 bar.
3. Never operate the equipment with high-pressure
gases other than compressed air.
Never use carbon dioxide, oxygen or another gas
from pressurized containers under any
circumstances.
4. Be careful of ignition and explosions.
Since sparks may fly during nailing, it is dangerous
to use this tool near lacquer, paint, benzine, thinner,
gasoline, gas, adhesives and similar inflammable
substances as they may ignite or explode. Under
no circumstances should this tool therefore be
used in the vicinity of such inflammable material.
5. Always wear eye protection (protective goggles).
When operating the power tool, always wear eye
protection, and ensure that surrounding people
wear eye protection too.
The possibility of fragments of the nails that were
not properly hit entering the eye is a threat to
sight. Eye protection can be bought at any
hardware store. Always wear eye protection while
operating this tool. Use either eye protection or
a wide vision mask over prescription glasses.
Employers should always enforce the use of eye
protection equipment.
6. Protect your ears and head.
When engaged in nailing work please wear ear
mufflers and head protection. Also, depending on
condition, ensure that surrounding people also
wear ear mufflers and head protection.
7. Pay attention to those working close to you.
It would be very dangerous if nails that were not
properly driven in should hit other people.
Therefore, always pay attention to the safety of
the people around you when using this tool.
Always make sure that nobody’s body, hands or
feet are close to the nail outlet.
8. Never point the nail outlet towards people.
Always assume the tool contains fasteners.
If the nail outlet is pointed towards people, serious
accidents may be caused if you mistakenly
discharge the tool. When connecting and
disconnecting the hose, during nail loading or
similar operations, be sure the nail outlet is not
pointed towards anyone (including yourself). Even
when no nails are loaded at all, it is dangerous
to discharge the tool while pointing it at someone,
so never attempt to do so. No horseplay. Respect
the tool as a working implement.
9. Before using the power tool, check the push
lever.
Before using the power tool make sure to check
that the push lever and valve operate properly.
Without nails loaded into the power tool, connect
the hose and check the following. If the sound
of operation occurs this indicates a fault, so in
3
such a case do not use the power tool until it
has been inspected and repaired.
䡬If merely pulling the trigger causes operating
sound of drive bit movement occur, the power
tool is faulty.
䡬If merely pushing the push lever against the
material to be nailed causes the sound of drive
bit movement to occur, the power tool is faulty.
Furthermore, with regard to the push lever,
please note that it must never be modified or
removed.
10. Use specified nails only.
Never use nails other than those specified and
described in these instructions.
11. Be careful when connecting the hose.
When connecting the hose and loading nails in
order not to fire the tool by mistake, make sure
of the followings.
䡬Do not touch the trigger.
䡬Do not allow the firing head to contact with any
surface.
䡬Keep the firing head down.
Strictly observe the above instructions, and always
make sure that no part of the body, hands or
legs is ever in front of the nail outlet.
12. Do not carelessly place your finger on the trigger.
Do not place your finger on the trigger except
when actually nailing. If you carry this tool or
hand it to someone while having your finger on
the trigger, you may inadvertently discharge a nail
and thus cause an accident.
13. Press the nail outlet firmly against the material
to be nailed.
When driving in nails, press the nail outlet firmly
against the material to be nailed. If the outlet is
not applied properly, the nails may rebound.
14. Keep hands and feet away from the firing head
when using.
It is very dangerous for a nail to hit the hands
or feet by mistake.
15. Beware of the tool’s kickback
Do not approach the top of the tool with your
head etc. during operation. This is dangerous
because the tool may recoil violently if the nail
currently being driven in comes into contact with
a previous nail or a knot in the wood.
16. Take care when nailing thin boards or the corners
of wood.
When nailing thin boards, the nails may pass right
through, as may also be the case when nailing
the corners of wood due to deviation of the nails.
In such cases, always make sure that there is no
one (and nobody’s hands or feet; etc.) behind the
thin board or next to the wood you are going to
nail.
17. Simultaneous nailing on both sides of the same
wall is dangerous
Under no circumstances should nailing be
performed on both sides of a wall at the same
time. This would be very dangerous since the
nails might pass through the wall and thus cause
injuries.
18. Do not use the power tool on scaffoldings, ladders.
The power tool shall not be used for specific
application for example:
– when changing one driving location to another
involves the use of scafforldings, stairs, ladders
or ladder alike constructions, e.g. roof laths,
– closing boxes or crates,
– fitting transportation safety systems e.g. on
vehicles and wagons
19. Do not disconnect the hose with your finger on
the trigger.
If you disconnect the hose with your finger on
the trigger, the next time the hose is connected,
there is a danger that the power tool will fire a
nail spontaneously, or operate incorrectly.
20. Disconnect the hose and take out any nails left
in the magazine after use.
Disconnect tool from air before doing tool
maintenance, cleaning a jammed fastener, leaving
work area, moving tool to another location, or
after use. It is very dangerous for a nail to be fired
by mistake.
21. When removing a nail which has become stuck,
make sure to first of all disconnect the hose and
release compressed air.
When removing a nail which has become stuck
in the nail outlet, first of all make sure to disconnect
the hose and release compressed air inside the
power tool.
Accidental firing of the nail could be very
dangerous.
22. A female plug (air socket) should not be used in
the body.
If a female plug is installed in the body, the
compressed air sometimes can not be drawn when
the hose is disconnected so avoid this.
The tool and air supply hose must have a hose
coupling such that all pressure is removed from
the tool when the coupling joint is disconnected.
23. When attaching and detaching the nose cap,
disconnect the hose.
When attaching the accessory nose cap to the tip
of the push lever and when detaching it, make
sure to disconnect the hose beforehand. It is very
dangerous for a nail to be fired by mistake.


Product specificaties

Merk: Hikoki
Categorie: Niet gecategoriseerd
Model: NT65M2

Heb je hulp nodig?

Als je hulp nodig hebt met Hikoki NT65M2 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Hikoki

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Electrolux

Electrolux STA9 Handleiding

23 November 2024
Electrolux

Electrolux UMP3 Handleiding

23 November 2024
Bosch

Bosch HEZ8TK36UC Handleiding

23 November 2024
Bosch

Bosch HEZ8ZZ36UC Handleiding

23 November 2024
Bosch

Bosch HDZIT301 Handleiding

23 November 2024
Bosch

Bosch HEZBS301 Handleiding

23 November 2024
LG

LG LX-330 Handleiding

23 November 2024
Bosch

Bosch KSZ2AVU00 Handleiding

22 November 2024