LVTG1000CP
LVTG1000CP
NH Disconnector vertical design LV size 3 1000A 185mm 3pole M12
Technical properties
Archiī˜¤tecī˜¤ture
Number of poles 3 P
Type of pole 3 P
Configī˜¤urī˜¤aī˜¤tion
Distance between rail centre, 40 mm No
Distance between rail centre, 50 mm No
Distance between rail centre, 60 mm No
Distance between rail centre, 100 mm No
Distance between rail centre, 185 mm Yes
Main elecī˜¤trical features
Rated operī˜¦aī˜¦tional voltage Ue 0 / 690 V AC
Frequency 50/60 Hz
Voltage
Rated insuī˜¦laī˜¦tion voltage 1000 V
Rated impulse withī˜¦stand voltage 12 kV
Elecī˜¤tric current
Rated current for Ue=400V AC according to
IEC 61439-1 5.3.2 1000 A
Rated current for Ue=500V AC according to
IEC 61439-1 5.3.2 1000 A
Rated current for Ue=690V AC according to
IEC 61439-1 5.3.2 1000 A
Rated current 1000 A
Rated short-ī˜¦time withī˜¦stand current 1s 15 kA
Convenī˜¦tional free air thermal current with
Trennmesser and std. cross section 1000 A
Acceptī˜¦able current rating with AC22
category B 1000 A
Acceptī˜¦able current rating with AC23
category B 1000 A
Elecī˜¤tric current / temperī˜¤ature
Rating current 40Ā°C 1000 A
Rating current 45Ā°C 950 A
Rating current 50Ā°C 900 A
Rating current 55Ā°C 850 A
Rating current 60Ā°C 800 A
Rating current 65Ā°C 750 A
Subject to technical modifications
Rating current 70Ā°C 700 A
Fuse
Fuse Size NH3
Dimenī˜¤sions
Height of installed product 188 mm
Length 743 mm
Width of installed product 100 mm
Width of the busbars 5 / 10 mm
Busbar distance 185 mm
Power
Total power loss under IN 318 W
Dissipī˜¦ated energy in cable 366 W
Endurī˜¤ance
Elecī˜¦tric endurī˜¦ance in number of cycles 100
Number of mechī˜¦anī˜¦ical operī˜¦aī˜¦tions 500
Total service life (mechī˜¦anī˜¦ical and elecī˜¦trical
endurī˜¦ance) IEC 60947-3 Table 4 600
Materī˜¤ials
Copper weight of the product 3980 g
Silver weight of the product 4.57 g
Material Plastic/ī˜¦metal
Installī˜¤aī˜¤tion, mounting
Tightī˜¦ening torque 32Nm
Torque at mounting on busbar 32 Nm
Connecī˜¤tion
Connecī˜¦tion cross-sect. flexī˜¦ible conductor 2x 30mm x 5mm - 2x 60mm x 5mm
Connecī˜¦tion cross-sect. rigid cable 2x 30mmx5mm - 2x60mī˜¦mx5mm
Connector type with permanī˜¦ently installed NH solid link 1000A
Type of connecī˜¦tion Screw connecī˜¦tion
Standī˜¤ards
Rated duties according to IEC 60947-1 4.3.4 Continuous operī˜¦aī˜¦tion
Operī˜¦aī˜¦tion of switching devices according to
IEC 60947-1 2.4
depending manual operī˜¦aī˜¦tion (of a mechī˜¦anī˜¦ical
switching device)
Utilī˜¦isaī˜¦tion category for Ue=400V AC
according to IEC 60947-3 Table 5 AC-22B
Utilī˜¦isaī˜¦tion category for Ue=500V AC
according to IEC 60947-3 Table 5 AC-21B
Utilī˜¦isaī˜¦tion category for Ue=690V AC
according to IEC 60947-3 Table 5 AC-21B
European directive WEEE concerned
Safety
Protecī˜¦tion index IP IP2X
Halogen free Yes
Subject to technical modifications
Use condiī˜¤tions
Operī˜¦ating temperī˜¦ature -25ā€¦55 Ā°C
Degree of polluī˜¦tion according to IEC 60664 /
IEC 60947-2 3
Storī˜¦age/transī˜¦port temperī˜¦ature -40ā€¦70 Ā°C
Subject to technical modifications


Product specificaties

Merk: Hager
Categorie: Niet gecategoriseerd
Model: LVTG1000CP
Gewicht: 7600 g
Breedte: 100 mm
Hoogte: 188 mm
Aantal: 1

Heb je hulp nodig?

Als je hulp nodig hebt met Hager LVTG1000CP stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Hager

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd