Introduction
Congratulations and thank you for
choosing Genelec!
Since 1978, Genelec has been guided
by a single idea to make perfect
active monitors that deliver neutral and
accurate sound in every kind of acoustical
environment. In Genelecs quest for this
ultimate goal, our unrivalled commitment
to research and development has led us
to continuously develop innovative driver
technology, electronic circuitry, enclosure
designs and more.
Our design philosophy is based on
sustainability and environmental values,
where industrial design serves our
products' acoustical performance. Your
Genelec product has been designed and
manufactured with care in our factory, in
Finland, using environmentally efficient
solutions to give you reliable operation
over many years.
Please take the time to read this manual.
Happy monitoring!
General Description
The Genelec 1238DF is a three-way
monitoring system for medium sized
control rooms. It performs well as free-
standing monitor as well as ush-mounted
in control room walls.
The 1238DF is fully
compatible with Genelec Loudspeaker
Manager GLM and the proprietary
Genelec loudspeaker control network and
Genelec SAM Series DSP Subwoofers.
It
is suited for recording, lm and video post-
production, broadcast monitoring as well
as for mastering.
T h e u n i q u e Di r e c t i v i t y C o n t ro l
Waveguide (DCW) technology by
Genelec provides excellent stereo imaging
and neutral frequency response even in
dicult acoustics.
With program material at a 2 meter
listening distance, the fast low distortion
ampliers drive a stereo system to peak
sound levels in excess of 124 dB SPL.
Drivers and Cabinet
Construction
The 1238DF reproduces low frequencies
with dual 210 mm (8 in) woofers. The
proprietary 130 mm (5 in) direct radiating
midrange driver, and a 25 mm (1 in) metal
dome tweeter are acoustically loaded by the
proprietary Directivity Control Waveguide.
All drivers are magnetically shielded.
Amplifiers and Signal
Processing
The 1238DF uses the RAM-L amplier unit.
The RAM-L is designed to be mounted in
a 19 inch rack. Digital signal processing in
the RAM-L amplier unit is done with high
precision algorithms, and includes driver
and amplier overload protection. The room
response compensations include highly
exible parametric lters, level alignment,
and acoustic delay compensation. These
allow accurate matching to all console
output sections and room acoustics.
Operating Environment
These monitors and their RAM-L ampliers
are designed for indoor use only. The
permissible ambient temperature is 15-35
degrees Celsius (50-95°F) and permissible
relative humidity between 20% and 80%.
Humidity condensation on the product is
not allowed during use. For instance, if the
product has been stored or transported in
a cool environment and then taken into a
warm room, it must be allowed to warm
up to the ambient temperature before
connecting to mains power.
Mounting Considerations
Place the monitor so that its acoustic axis
is aimed towards the listening position
(see Figures 1 and 2). Place monitors
with left-right symmetry and at an equal
distance from the listening position.
Acoustic reflections from objects close
to monitors and the listening position
can cause colouration and blurring of the
sound image. Symmetrical positioning of
reective objects maintains good stereo
imaging. When sot (ush) mounting, the
wall surface should extend to the monitor,
forming a continuous surface.
Minimum Clearances
The ambient temperature around the
amplifier must not exceed 35 degrees
Celsius (95°F).
When the RAM-L amplier is mounted
in a 19 in rack, the minimum free space is
1/2 U both above and below the amplier
and both sides of the amplier fully open
to enable free movement of air. Use the
included rack mount front plate to ensure
sufficient space above and below the
amplier.
When the RAM-L is mounted on a table,
shelf or similar solid surface, there must
be a free space of at least 250 mm (10 in)
above and 10 cm (4 in) on both sides of the
amplier. Free air ow must be possible in
the front side of the amplier.
Description Of Connectors
“MAINS INPUTConnector
Connect to the mains supply. The RAM-L
amplier accepts any AC 50/60 Hz mains
voltage between 100 and 230 Volts.
“DIGITAL IN AES/EBUConnector
The monitor defaults to reproducing an
analog input signal. The digital audio AES/
EBU input is selected automatically when
a valid digital audio signal is presented.
Use GLM software to dene the AES/EBU
subframe to monitor.
“DIGITAL THRU AES/EBU” Connector
This output carries an unaltered copy of
the digital audio signal and can be used
for daisy-chaining the signal up to three
additional SAM monitors or subwoofers.
“ANALOG INConnector
The maximum input level of the analog
input is +25.0 dBu. The analog input must
not be overloaded, otherwise distortion
will result. When the maximum input is
exceeded, the enclosure front panel light
turns red, indicating the overload.
The sensitivity of the monitor system is
set using the GLM software. Coming from
the factory, the analog input is set to the
highest sensitivity, resulting in a sound
output of 100 dB SPL for a -6 dBu analog
input signal.
“CONTROL NETWORKConnectors
The RJ45 sockets connect the monitor
to the proprietary Genelec Loudspeaker
Manager (GLM) network. Do not
connect to Ethernet LAN.
“Loudspeaker ConnectorsGroup
These connectors are used for connecting
the rack mounted RAM-L amplier to the
monitor enclosure.
1. “LED” Connector
This RJ45 socket is a connection for
the front panel warning LED.
2. “Woofer” Connector
A standard four-pole Speakon cable
connects to the woofer.
3. M i d ra n g e / Tw e e t e r C o n n e c t o r
A standard four-pole Speakon cable
connects to the the midrange and
tweeter.
Connecting Cables
Insert the connectors into the appropriate
s o c k e t s W O O F E R , M I D R A N G E /
TWEETERand “LED CONNECTOR” found
on the rear panel of the amplier unit and the
rear of the monitor. Note that each RAM-L
amplier is individually calibrated for use with
the monitor enclosure that it is delivered with
and marked with the same serial number. Do
not mix these amplier/monitor pairs.
Figure 3. GLM network cabling
Figure 1. The location of the acoustic axis.
L
R
C
30
0
RS
LS
100 120
0 - 0
Figure 2. Recommended placement
and alignment of monitors in a 5-chan-
nel system (ITU-R BS.775-1)
Figure 4. Connector panel of the RAM-L amplier.
LED CONNECTOR
CONNE CT ONLY TOGEN ELEC N ETW ORK.
ANALOG
IN
DIGITAL IN
AES/EBU
DIGI L THRUTA
AES/EBU MAINS INPUT
50 / 60 Hz 750 W
100 - 230 V~
SERIALNUMBER
MIDRANGE /
TWEETER
WOOFER
LOUDSPEAKER CONNECTORS
RAM-L AMPLIFIER
MODULE
www.genelec.com
MADE IN FINLAND
CONTROL NETWORK
21 3 THRU
IN
1
1
2 3
3
2-
GND
+
DIRECT
LOUDSPEAKER
CONNECTOR
CONSULT OPERATING
MANUAL BEFORE
OPENING !
ANALOG
AUDIO
INPUT
DIGITAL
AUDIO
INPUT
DIGITAL
THRU
CONNECTOR
CONTROL
NETWORK
CONNECTORS
LOUDSPEAKER CONNECTOR GROUP
MAINS
CONNECTOR
Cable gauge Max. length
2.0 mm2 (14 AWG) 30 m (100 ft)
3.3 mm2 (12 AWG) 40 m (130 ft)
5.3 mm2 (10 AWG) 60 m (200 ft)
Table 1. Recommended cable thicknesses
for dierent lengths of signal cable
LISTENING
POSITION
MICROPHONE
GLM
NETWORK
GLM
NETWORK
GLM
NETWORK
USB
RAM-LRAM-L RAM-L
a
272 mm
10 3/4 in
196 mm
7 3/4 in
a
235 mm
9 1/4 in
456 mm
17
15/16 in


Product specificaties

Merk: Genelec
Categorie: Speaker
Model: 1238DF