GE ZXR7510C Handleiding


Lees hieronder de πŸ“– handleiding in het Nederlandse voor GE ZXR7510C (12 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 7 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
If you have questions, call 800.GE.CARES or visit our website at: www.monogram.com
Installation
Instructions
ZXR758 and ZXR7510
Recirculating Accessories
For Model ZV750, Vent Hood
Mon
ogram
Installation Preparation
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRICAL
SHOCK OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
A. Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact the
manufacturer.
B. Before servicing or cleaning unit, switch power off
at the service panel and lock service panel to prevent
power from being switched on accidentally. If the
service panel cannot be locked, fasten a tag or
prominent warning label to the panel.
For general ventilating use only. Do not use to
exhaust hazardous or explosive materials or vapors.
Structural framing, installation work and electrical
wiring must be done by qualified person(s). In
accordance with all applicable codes and standards
including fire-rated construction.
Sufficient air is needed for proper combustion
and exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent back drafting.
Follow the heating equipment manufacturer’s
guideline and safety standards such as those
published by the National Fire Protection Association
(NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
Local codes vary. Installation electrical connections
and grounding must comply with applicable codes.
In the absence of local codes, the vent should be
installed in accordance with National Electrical
Code ANSI/NFPA 70-1990 or latest edition.
2
BEFORE YOU BEGIN
Read these instructions completely and carefully.
β€’ IMPORTANT – Save these instructions for
local inspector’s use.
β€’ IMPORTANT – Observe all governing
codes and ordinances.
β€’ – Be sure to leave these instruc-Note to Installer
tions with the Consumer.
β€’ Note to Consumer – Keep these instructions with
your Owner’s Manual for future reference.
β€’ Skill Level – Installation of this appliance requires
basic mechanical and electrical skills.
β€’ Completion time – 1 to 3 hours.
β€’ Proper installation is the responsibility of the installer.
β€’ Product failure due to improper installation is not
covered under the Warranty.
For Monogram local service in your area,
1.800.444.1845.
For Monogram service in Canada, call
1-.888.880.3030.
For Monogram Parts and Accessories, call
1.800.626.2002.
CAUTION:
Due to the weight and size of this vent hood and to
reduce the risk of personal injury or damage to the
product, TWO PEOPLE ARE REQUIRED FOR
PROPER INSTALLATION.
WARNING:
To reduce the risk of fire or electrical shock, do not use
this hood with any external solid-state speed control
device. Any such alteration from original factory wiring
could result in damage to the unit and/or create an
electrical safety hazard.
CONTENTS
Installation Preparation
Required Accessories .................................................. 3
Product Dimensions ................................................... 3
Duct Cover Accessories .............................................. 4
Power Supply .............................................................. 4
Tools and Materials Required .................................... 4
Remove Packaging, Check Contents ......................... 5
Installation Instructions
Step 1, Determine Installation Location ................... 6
Step 2, Install Mouning Brackets ............................... 6
Step 3, Install the Hood ............................................. 7
Step 4, Size Duct Piece ............................................... 7
Step 5, Install Air Deflector Assembly ....................... 7
Step 6, Connect Electrical .......................................... 8
Step 7, Install Duct Covers and Utility Bars .............. 8
Step 8, Install Filters ................................................... 9
Step 9, Finalize Installation ........................................ 9
Installation Preparation
3
REQUIRED ACCESSORIES
This book provides step by step instructions to install the
Monogram ZV750 wall mounted hood for recirculating
operation.
β€’ One of the following accessory kits is required for
non-vented wall mounted installations of model ZV750.
Choose the correct kit according to ceiling heights:
ZXR758 – For 8 to 9 ft. ceiling height.
ZXR7510 – For 9 to 10 ft. ceiling height.
β€’ Order the required accessory at the same time as the
vent hood and have on site before installation.
β€’ Each kit includes decorative duct cover, air deflector
and charcoal filters.
PRODUCT DIMENSIONS
The vent hood must be installed 24" min. and 30" max.
above the cooking surface. 25-1/2" is recommended for
best performance and to insure that the duct cover
meets the ceiling. The cooking surface should be at least
36” above the floor. Installation will be easier if the vent
hood is installed before the cooktop and countertop is
installed.
* ZXR758
26-1/4" for 8 ft. Ceiling
38-1/4" for 9 ft. Ceiling
ZXR7510
34-1/4" to 50-1/4" for
9 ft. to 10 ft. Ceiling
* The distance between the cooking surface and the bottom of the
hood must be at least 24” and up to 30” The 25-1/2” recommended
installation height, above the standard 36” countertop, will insure
duct cover fit to the ceiling.
*25-1/2" Recommended
36" Min.
*Height
to Ceiling
8-1/4"
34-5/8"
21-5/8"


Product specificaties

Merk: GE
Categorie: Niet gecategoriseerd
Model: ZXR7510C

Heb je hulp nodig?

Als je hulp nodig hebt met GE ZXR7510C stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd GE

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd