GE Profile ASM14AB Handleiding

GE Airco Profile ASM14AB

Lees hieronder de 📖 handleiding in het Nederlandse voor GE Profile ASM14AB (20 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 34 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/20
49-7405-1 11-00 JR
AST10
ASM12
ASP12
AST12
ASV12
ASM14
ASP14
ASV14
ASM16
ASH18
ASM18
ASN18
ASP18
AST18
ASV18
ASM22
ASH24
ASM24
ASN24
ASP24
ASV24
ASW24
Air Conditioners
Owner’s Manual &
Installation Instructions
www.GEAppliances.com
Safety Information
Adapter Plugs . . . . . . . . . . . . . . . . . .3
Connect Electricity . . . . . . . . . . . . . .2
Extension Cords . . . . . . . . . . . . . . . .3
Safety Precautions . . . . . . . . . . . . . . .2
Operating Instructions
Controls—Control Knobs . . . . . .6, 7
Controls—Touch Pads . . . . . . . . .4, 5
Care and Cleaning
Air Filter . . . . . . . . . . . . . . . . . . . . . . .8
Grille and Case . . . . . . . . . . . . . . . . .8
Outdoor Coils . . . . . . . . . . . . . . . . . .8
Installation Instructions
Through the Wall
Installation–Optional . . . . . . . . . .15
Window Installation . . . . . . . . .9–14
Troubleshooting Tips . . . . . . . .16
Normal Operating
Sounds . . . . . . . . . . . . . . . . . . . . . . . .16
Consumer Support
Consumer Support . . . .Back Cover
Product Registration . . . . . . . .17, 18
Warranty . . . . . . . . . . . . . . . . . . . . . .19
Write the model and serial numbers here:
# ________________________________
# ________________________________
Find these numbers on a label on the
side of the air conditioner.
IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING.
WARNING!
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock
or personal injury.
â–  Use this appliance only for its intended
purpose as described in this Owner’s
Manual.
â– This air conditioner must be properly
installed in accordance with the Installation
Instructions before it is used.
â– Never unplug your air conditioner by pulling
on the power cord. Always grip plug firmly
and pull straight out from the receptacle.
â–  Repair or replace immediately all electric
service cords that have become frayed or
otherwise damaged. Do not use a cord that
shows cracks or abrasion damage along its
length or at either the plug or connector end.
â–  Turn the mode control
OFF
and unplug
your air conditioner before making any
repairs or cleaning.
NOTE:
We strongly recommend that any
servicing be performed by a qualified
individual.
■ For your safety…do not store or use
combustible materials, gasoline or other
flammable vapors or liquids in the vicinity
of this or any other appliance.
SAFETY PRECAUTIONS
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord. For
personal safety, this appliance must be properly
grounded.
The power cord of this appliance is equipped
with a 3-prong (grounding) plug which mates
with a standard 3-prong (grounding) wall
outlet to minimize the possibility of electric
shock hazard from this appliance.
Have the wall outlet and circuit checked by a
qualified electrician to make sure the outlet is
properly grounded.
Where a 2-prong wall outlet is encountered,
it is your personal responsibility and obligation
to have it replaced with a properly grounded
3-prong wall outlet.
The air conditioner should always be
plugged into its own individual electrical
outlet which has a voltage rating that matches
the rating plate.
This provides the best performance and also
prevents overloading house wiring circuits
which could cause a fire hazard from
overheated wires.
See the Installation Instructions,
Electrical
Requirements
section for specific electrical
connection requirements.
HOW TO CONNECT ELECTRICITY
Consumer Support Troubleshooting Tips Operating Instructions Safety InstructionsInstallation Instructions
2
3
Consumer SupportTroubleshooting TipsOperating Instructions
Safety Instructions Installation Instructions
www.GEAppliances.com
WARNING!
Because of potential safety hazards under certain
conditions, we strongly recommend against the
use of an extension cord.
However, if you must use an extension cord,
it is absolutely necessary that it be a UL-listed,
14 gauge, 3-wire grounding type appliance
extension cord having a grounding type plug
and outlet and that the electrical rating of the
cord be 15 amperes (minimum) and 125 volts.
CAUTION:
DO NOT use an extension cord with any of the
230/208 volt models.
USE OF EXTENSION CORDS–
115-Volt models only
Because of potential safety hazards under certain
conditions, we strongly recommend against the use
of an adapter plug.
However, if you must use an adapter, where
local codes permit, a
temporary connection
may
be made to a properly grounded 2-prong wall
outlet by use of a UL-listed adapter available at
most local hardware stores.
The larger slot in the adapter must be aligned
with the larger slot in the wall outlet to provide
proper polarity in the connection of the power
cord.
When disconnecting the power cord from the
adapter, always hold the adapter in place with
one hand while pulling the power cord plug
with the other hand. If this is not done, the
adapter ground terminal is very likely to break
with repeated use.
If the adapter ground terminal breaks,
DO NOT USE
the air conditioner until a
proper ground has been established.
Attaching the adapter ground terminal to a wall outlet
cover screw does not ground the appliance unless the
cover screw is metal, and not insulated, and the wall
outlet is grounded through the house wiring. You should
have the circuit checked by a qualified electrician to
make sure the outlet is properly grounded.
USE OF ADAPTER PLUGS –
115-Volt models only
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
SAVE THESE INSTRUCTIONS


Product specificaties

Merk: GE
Categorie: Airco
Model: Profile ASM14AB

Heb je hulp nodig?

Als je hulp nodig hebt met GE Profile ASM14AB stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco GE

Handleiding Airco

Nieuwste handleidingen voor Airco