GE GTDP300GMWS Handleiding

GE Wasdroger GTDP300GMWS

Lees hieronder de 📖 handleiding in het Nederlandse voor GE GTDP300GMWS (12 pagina's) in de categorie Wasdroger. Deze handleiding was nuttig voor 38 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
WARNING RISK OF FIRE
7RUHGXFHWKHULVNRIVHYHUHLQMXU\RUGHDWKIROORZDOOLQVWDOODWLRQLQVWUXFWLRQV
&ORWKHVGU\HULQVWDOODWLRQPXVWEHSHUIRUPHGE\DTXDOL¿HGLQVWDOOHU
,QVWDOOWKHFORWKHVGU\HUDFFRUGLQJWRWKHVHLQVWUXFWLRQVDQGLQDFFRUGDQFHZLWKORFDO
FRGHV,QWKHDEVHQFHRIORFDOFRGHVLQVWDOODWLRQPXVWFRPSO\ZLWK1DWLRQDO)XHO*DV
&RGH$16,=1)3$RUWKH&DQDGLDQ1DWXUDO*DVDQG3URSDQH,QVWDOODWLRQ&RGH
&6$%
California Safe Drinking Water and Toxic Enforcement Act.
7KLVDFWUHTXLUHVWKHJRYHUQRURI&DOLIRUQLDWRSXEOLVKDOLVWRIVXEVWDQFHVNQRZQWRWKH
VWDWHWRFDXVHFDQFHUELUWKGHIHFWVRURWKHUUHSURGXFWLYHKDUPDQGUHTXLUHVEXVLQHVVHV
WRZDUQFXVWRPHUVRISRWHQWLDOH[SRVXUHWRVXFKVXEVWDQFHV*DVDSSOLDQFHVFDQ
FDXVHPLQRUH[SRVXUHWRIRXURIWKHVHVXEVWDQFHVQDPHO\EHQ]HQHFDUERQPRQR[LGH
IRUPDOGHK\GHDQGVRRWFDXVHGSULPDULO\E\WKHLQFRPSOHWHFRPEXVWLRQRIQDWXUDOJDV
RU/3IXHOV3URSHUO\DGMXVWHGGU\HUVZLOOPLQLPL]HLQFRPSOHWHFRPEXVWLRQ([SRVXUH
WRWKHVHVXEVWDQFHVFDQEHPLQLPL]HGIXUWKHUE\SURSHUO\YHQWLQJWKHGU\HUWRWKH
RXWGRRUV
7KLVGU\HUPXVWEHH[KDXVWHGWRWKHRXWGRRUV
8VHRQO\µULJLGPHWDOGXFWLQJIRUH[KDXVWLQJWKHFORWKHVGU\HUWRWKHRXWGRRUV
DO NOTLQVWDOODFORWKHVGU\HUZLWKÀH[LEOHSODVWLFGXFWLQJPDWHULDOV,IÀH[LEOHPHWDO
VHPLULJLGRUIRLOW\SHGXFWLVLQVWDOOHGLWPXVWEH8/OLVWHGDQGLQVWDOOHGLQDFFRUGDQFH
ZLWKWKHLQVWUXFWLRQVIRXQGLQ´&RQQHFWLQJ7KH'U\HU7R+RXVH9HQWµRQSDJHRIWKLV
PDQXDO)OH[LEOHYHQWLQJPDWHULDOVDUHNQRZQWRFROODSVHEHHDVLO\FUXVKHGDQGWUDS
OLQW7KHVHFRQGLWLRQVZLOOREVWUXFWGU\HUDLUÀRZDQGLQFUHDVHWKHULVNRI¿UH
'RQRWLQVWDOORUVWRUHWKLVDSSOLDQFHLQDQ\ORFDWLRQZKHUHLWFRXOGEHH[SRVHGWRZDWHU
DQGRUZHDWKHU
6DYHWKHVHLQVWUXFWLRQV,QVWDOOHUV%HVXUHWROHDYHWKHVHLQVWUXFWLRQVZLWKWKH
FXVWRPHU
In the state of Massachusetts:
Insta OO L P E S U G T OL¿ G U OL G Uat on ust e e foUPe E\ a ua e o cense cont actoU
SO E\uPEeU oU J as¿ U T OL¿ G U OL Gtte ua e o cense the state
When usL J E OO \S J n a t e as shut off theY OYa es \ OO E sha e ThanGOe t\S e
A À J Z P [ G  e[LEOe as connectoU hen useG ust not e cee feet
Installation
Instructions
Gas Dryer

4 " &uestions on Installation all: GE&ARES 8S
RUYLVLWRXUZHEVLWHDWwww.GEAppliances.com (US)
% < 8 %EFORE O EGIN
Read these instructions completely and
carefully
IM ORTANT3 6DYHWKHVHLQVWUXFWLRQVIRU
ORFDOLQVSHFWRU·VXVH
IM ORTANT3 2EVHUYHDOOJRYHUQLQJFRGHV
DQGRUGLQDQFHV
Note to Installer %HVXUHWROHDYHWKHVH
LQVWUXFWLRQVZLWKWKHFXVWRPHU
Note to & ustomer .HHSWKHVHLQVWUXFWLRQV
ZLWK\RXU2ZQHU·V0DQXDOIRUIXWXUHUHIHUHQFH
%HIRUHWKHROGGU\HULVUHPRYHGIURPVHUYLFHRU
GLVFDUGHGUHPRYHWKHGU\HUGRRU
,QVSHFWWKHGU\HUH[KDXVWRXWOHWDQGVWUDLJKWHQ
WKHRXWOHWZDOOVLIWKH\DUHEHQW
6HUYLFHLQIRUPDWLRQDQGWKHZLULQJGLDJUDP
DUHORFDWHGLQWKHFRQWUROFRQVROH
'RQRWDOORZFKLOGUHQRQRULQWKHDSSOLDQFH
&ORVHVXSHUYLVLRQRIFKLOGUHQLVQHFHVVDU\ZKHQ
WKHDSSOLDQFHLVXVHGQHDUFKLOGUHQ
,QVWDOOWKHGU\HUZKHUHWKHWHPSHUDWXUHLV
DERYH)IRUVDWLVIDFWRU\RSHUDWLRQRIWKH
GU\HUFRQWUROV\VWHP
3URGXFWIDLOXUHGXHWRLPSURSHULQVWDOODWLRQLV
QRWFRYHUHGXQGHUWKH:DUUDQW\
LEVEL
8" PIPE WRENCH
10" ADJUSTABLE WRENCHES
(x2)
TOOLS YOU
WILL NEED
SLIP JOINT PLIERS FLAT BLADE SCREWDRIVER
M ATERIALS YOU WILL NEED
EXHAUST HOOD
FLEXIBLE GAS LINE CONNECTOR
SOAP SOLUTION
FOR LEAK DETECTION
PIPE
COMPOUND
DUCT TAPE
GLOVES
SAFETY GLASSES
4" DIAM METAL ELBOW
4" DUCT CLAMPS
OR
4" SPRING CLAMPS
(x2)
(x2)
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT
(IF NEEDED.)
234D1582P003 31-16225-2 03-12 GE
6WHS9HULI\<RXU*DV,QVWDOODWLRQVHHVHFWLRQ
6WHS3UHSDUHWKH$UHDDQG([KDXVWIRU,QVWDOODWLRQRI
1HZ'U\HUVHHVHFWLRQ
6WHS&KHFNDQG,QVXUHWKH([LVWLQJ([WHUQDO([KDXVWLV
&OHDQVHHVHFWLRQDQG0HHWV$WWDFKHG,QVWDOODWLRQ
6SHFL¿FDWLRQVVHHVHFWLRQ
6WHS5HPRYHWKH)RDP6KLSSLQJ3DGVVHHVHFWLRQ
6WHS0RYHWKH'U\HUWRWKH'HVLUHG/RFDWLRQ
6WHS/HYHO<RXU'U\HUVHHVHFWLRQ
6WHS&RQQHFWWKH*DV6XSSO\VHHVHFWLRQDQGFKHFNIRU
OHDNVVHHVHFWLRQ
6WHS&RQQHFWWKH([WHUQDO([KDXVWVHHVHFWLRQ
6WHS&RQQHFWWKH3RZHU6XSSO\VHHVHFWLRQ
6WHS&KHFNWKH2SHUDWLRQRIWKH3RZHU6XSSO\*DV
&RQQHFWLRQVDQG9HQWLQJ
6WHS3ODFHWKH2ZQHU·V0DQXDODQGWKH,QVWDOODWLRQ
,QVWUXFWLRQVLQDORFDWLRQZKHUHWKH\ZLOOEHQRWLFHG
E\WKHRZQHU
)RU$OFRYHRU&ORVHW,QVWDOODWLRQVHHVHFWLRQ
)RU%DWKURRPRU%HGURRP,QVWDOODWLRQVHHVHFWLRQ
)RU0RELOHRU0DQXIDFWXUHG+RPHVHHVHFWLRQ
)RUJDUDJHLQVWDOODWLRQLIDOORZHGE\ORFDOFRGHVVHHVHFWLRQ

D
E
S
I
G
N
C
E
R
T
I
F
I
E
D
Installation Instructions
2
Minimum learance Other Than Alco& Ye or &loset Installation
0LQLPXPFOHDUDQFHWRFRPEXVWLEOHVXUIDFHVDQGIRUDLURSHQLQJDUHLQFOHDUDQFHERWKVLGHVDQGLQUHDU
&RQVLGHUDWLRQ mustEHJLYHQWRSURYLGHDGHTXDWHFOHDUDQFHIRULQVWDOODWLRQDQGVHUYLFH
2 GAS RE48IREMENTS
WARNING
Installation must conform to local codes and
ordinances sence or in their aE  the NATIONA/ 8 / F E
GAS &ODE ANSI =22
J T Z 9 Y  % This as dryer is e uipped ith a al e urner
Assem sin Ely for use only Zith natural Jas 8 J
con it WE2Yersion N ;2 your local ser ice  Y
or ith Jani] Yation can con ert this dryer for use Z
propane /3 J as A ERSIONS M ST E MADE // &ON9 8 % %<
3 3 / 3 /RO ER/< TRAINED AND 48A IFIED ERSONNE AND
IN A ORDAN E WIT&& & + / & / & O A ODES AND ORDINAN E &
RE48IREMENTS
 E J The dryer must e disconnected from the as supply
pipinJ J J system durin any pressure testin of that
system at a test pressure in e cess of [  3 3 SI  K a
E J J The dryer must e isolated from the as supply pipin
system Ey closinJ the eTuipment shutoff YalYe durinJ
any pressure testin of the J Jas supply pipinJ of test
pressure e ual to or less than T  3 3 SI  K a
GAS S833/<
 $LQ1DWLRQDO3LSH7DSHUWKUHDGSOXJJHGWDSSLQJ
DFFHVVLEOHIRUWHVWJDXJHFRQQHFWLRQPXVWEHLQVWDOOHG
LPPHGLDWHO\XSVWUHDPRIWKHJDVVXSSO\FRQQHFWLRQWR
WKHGU\HU&RQWDFW\RXUORFDOJDVXWLOLW\VKRXOG\RXKDYH
TXHVWLRQVRQWKHLQVWDOODWLRQRIWKHSOXJJHGWDSSLQJ
 6XSSO\OLQHLVWREHLQULJLGSLSHDQGHTXLSSHGZLWK
DQDFFHVVLEOHVKXWRȺZLWKLQIWRIDQGLQWKHVDPH
URRPZLWKWKHGU\HU
 8VHSLSHWKUHDGVHDOHUFRPSRXQGRU7HÀRQWDSHDSSUR
SULDWHIRUQDWXUDORU/3JDV
 <RXPXVWXVHZLWKWKLVGU\HUDÀH[LEOHPHWDOFRQQHFWRU
OLVWHGFRQQHFWRU$16,=&6$7KHOHQJWKRIWKH
FRQQHFWVKDOOQRWH[FHHGIW
 &RQQHFWÀH[LEOHPHWDOFRQQHFWRUWRGU\HUDQGJDVVXSSO\
 2SHQVKXWRȺYDOYH
INTERNAL DUCT
OPENING CHECK THA T EXHAUST
HOOD DAMPER OPENS
AND CLOSES FREE LY.
WALL
TILT THE DRYER SIDEWAYS
AND REMOVE THE FOAM
SHIPPING PADS BY
PULLING AT THE SIDES
AND BREAKING THEM
AWAY FROM THE DRYER
LEGS. BE SURE TO
REMOVE ALL OF THE
FOAM PIECES AROUND
THE LEGS.
3 3RE ARING FOR INSTA//ATION
OF NEW DRYER
TI3: Install your dryer Eefore installinJ your Zasher
This Zill alloZ Eetter access Zhen installinJ dryer
e haust[ 
DISCONNECTING GAS
REMO ING 9 /INT FROM WA//
E A;+ 8ST O3ENING
 Y Remo e and discard e[ Jistin plastic or metal foil
transition duct and replace Zith 8/ listed transition
duct
DISCONNECT AND DISCARD OLD
FLEXIBLE GAS CONNECTOR AND
OLD TRANSITION DUCTING
MATERIAL. REPLACE WITH NEW
CSA(AGA) APPROVED FLEXIBLE
GAS LINE CONNECTOR AND UL
APPROVED TRANSITION DUCT.
TURN GAS
SHUT-OFF VALVE
TO THE OFF
POSITION.
WARNING NE ER RE9 8 /SE O D
F E I/ ; %/E CONNECTORS
7KHXVHRIROGÀH[LEOHFRQQHFWRUVFDQFDXVHOHDNV
DQGSHUVRQDOLQMXU\$OZD\VXVHQHZÀH[LEOHFRQQHF
WRUVZKHQLQVWDOOLQJJDVDSSOLDQFHV
DRYER GAS SUPPLY CONNECTION
2"
2-5/8" 3/8" NPT MALE THREAD GAS SUPPLY
NOTE: Add to vertical dimension
the distance between cabinet
bottom to floor.
 *DVFORWKHVGU\HUVLQSXWUDWLQJVDUHEDVHGRQVHDOHYHO
RSHUDWLRQDQGQHHGQRWEHDGMXVWHGIRURSHUDWLRQDWRU
EHORZIWHOHYDWLRQ
)RURSHUDWLRQDWHOHYDWLRQVDERYHIWLQSXWUDWLQJV
VKRXOGEHUHGXFHGDWDUDWHRISHUFHQWIRUHDFK
IWDERYHVHDOHYHO
,QVWDOODWLRQPXVWFRQIRUPWRORFDOFRGHVDQGRUGLQDQFHVRU
LQWKHLUDEVHQFHWKH1$7,21$/)8(/*$6&2'($16,=
AD-8STING FOR E/ 9E ATION
Installation Instructions
3
/EAK TEST
RECONNECTING GAS
Note:7KHFRQQHFWRUDQG¿WWLQJVDUHGHVLJQHGIRUXVH
RQO\RQWKHRULJLQDOLQVWDOODWLRQDQGDUHQRWWREHUHXVHG
IRUDQRWKHUDSSOLDQFHRUDWDQRWKHUORFDWLRQ.HHSÀDUH
HQGRIDGDSWRUIUHHRIJUHDVHRLODQGWKUHDGVHDODQW
CA8TION: 8VHDGDSWHUVDVVKRZQ&RQQHFWRU
QXWVPXVWQRWEHFRQQHFWHGGLUHFWO\WRSLSHWKUHDGV
WARNING: NE ER 9 8SE AN O3EN
F AME TO TEST FOR GAS / /EAKS
FLARE NPT
PIPE SIZE
Listed connector ANSI Z21.24
/
CSA 6.10
1/8" NPT PIPE
PLUG FOR
CHECKING GAS
INLET PRESSURE
AT LEAST 1/2"
3/8" NPT
TIGHTEN THE FLEXIBLE
GAS LINE USING TWO
ADJUSTABLE WRENCHES.
TIGHTEN ALL CONNECTIONS
USING TWO ADJUSTABLE WRENCHES.
DO NOT OVERTORQUE GAS CONNECTIONS!


Product specificaties

Merk: GE
Categorie: Wasdroger
Model: GTDP300GMWS

Heb je hulp nodig?

Als je hulp nodig hebt met GE GTDP300GMWS stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Wasdroger GE

Handleiding Wasdroger

Nieuwste handleidingen voor Wasdroger