GCDX200EM/GCDX205EM
GE® 6.0 cu. ft. capacity DuraDrum electric dryer
36 42
27
25-1/2
2-1/2
25-1/2*
Side View Rear View
4-3/4
25-3/4
23-1/2
11-3/4
*24-1/2" from the edge of the side panel to the front
25-1/2" from the front edge of endcaps.
5
Back View
Power
Cord Hole
4-1/2
Power Cord Locations
Electric Dryer Rating:
240V 5600W 24A 60Hz
208V 4400W 22A 60Hz
Exhaust Option: 4-way rear, right, left
and bottom
Circuit Requirements: An individual,
properly-grounded branch circuit, protected
by a 30-amp circuit breaker or a time-delay
fuse, is required.
Note: Dryer wall outlet must be located within
36" of service cord entry and acessible when
dryer is mounted in position.
Installation Information: For complete
information, see installation instructions
packed with your dryer.
Dimensions and Installation Information (in inches)
For complete information, see installation instructions packed with your dryer.
Ducting Materials:
For best performance, this dryer should be vented with 4" diameter all rigid metal
exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal (semi-
rigid) ducting can be used (Kit WX08X10077). In special installations, it may be
necessary to connect the dryer to the house vent using a flexible metal (foil-type) duct.
A UL-listed flexible metal (foil-type) duct may be used ONLY in installations where rigid
metal or flexible metal (semi-rigid) ducting cannot be used AND where a 4” diameter
can be maintained throughout the entire length of the transition duct. Please see
installation instruction packed with your dryer for complete instructions when using
flexible metal (foil type) ducting.
Exhaust Length Calculation:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the
side or bottom of dryer, add one turn.
2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated
is shown in the table. A turn of 45° or less may be ignored. Two 45° turns within the
duct length should be treated as a 90° elbow. A turn over 45° should be treated as a
90° elbow.
Dryers be must exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any
enclosed house floor (crawl space), or into an attic, since the accumulated lint could
create a fire hazard or moisture could cause damage. Never terminate the exhaust
into a common duct or plenum with a kitchen exhaust, since the combination of lint
and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts,
bird nesting, etc. The wall cap must also be located at least 12" above the ground or
any other obstruction with the opening pointed down.
For more information on venting kits and accessories, please call 1-800-GE-CARES.
Special Installation Requirements
Alcove or Closet Installation:
If your dryer is approved for installation in an alcove or closet, it will be stated on a label
on the dryer back.
The dryer MUST be exhausted to the outside.
Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side; 3" front and rear
Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52.
Closet doors must be louvered or otherwise ventilated and must contain a minimum
of 60 sq. in. of open area equally distributed. If this closet contains both a washer and
a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:
The dryer MUST be exhausted to the outdoors.
The installation must conform with the local codes, or in the absence of local codes,
with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
Minimum Clearances other than Alcove or Closet Installation:
Minimum clearances to combustible surfaces are: 0" both sides; 3" rear
Dryer Exhausting Information : Use metal duct only, vertical and horizontal ducting.
Best performance
Domestic
dryer models
Maximum length of 4"
dia. rigid l meta duct
Number
of
90°
turns
Exhaust hood type
A
4"
opening
B
2-1/2"
opening
7.0, 6.0 . and 5.8 cu ft.
capacity models
all electric dr yers
0
1
2
3
4
90 ft.
60 ft.
45 .ft
35 .ft
25 ft.
60 ft.
45 .ft
35 .ft
25 ft.
15 ft.
A
4
B
2-1/2
A
Specification Created 7/10 370293
GCDX200EM/GCDX205EM
GE® 6.0 cu. ft. capacity DuraDrum electric dryer
Features and Benefits
Auto Dry - Monitors air temperature with an automatic thermostat
and ends the cycle when clothes are properly dried
Rotary electromechanical controls - Easy-to-use controls make
it simple to set cycles
4 heat selections - Provide the right temperatures for your
clothes-drying needs
Delicates cycle - Low-heat setting helps protect heat-sensitive
fabrics, like microfiber and rayon or nylon
Up to 90 ft. venting capability - Has long equivalent ducting
performance for more flexible installation
Interior dryer light - Convenient interior light helps you easily
see clothes
Model GCDX200EMWW –White on white
Model GCDX205EMCCBisque on bisque
Specification Created 7/10 370293
GCDX200EM/GCDX205EM
GE® 6.0 cu. ft. capacity DuraDrum electric dryer


Product specificaties

Merk: GE
Categorie: Wasdroger
Model: GCDX205EMCC

Heb je hulp nodig?

Als je hulp nodig hebt met GE GCDX205EMCC stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Wasdroger GE

Handleiding Wasdroger

Nieuwste handleidingen voor Wasdroger