GE DuraDrum GTDX300EMWS Handleiding

GE Wasdroger DuraDrum GTDX300EMWS

Lees hieronder de 📖 handleiding in het Nederlandse voor GE DuraDrum GTDX300EMWS (8 pagina's) in de categorie Wasdroger. Deze handleiding was nuttig voor 31 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
WARNING RISK OF FIRE
 7RUHGXFHWKHULVNRIVHYHUHLQMXU\RUGHDWKIROORZDOOLQVWDOODWLRQ
LQVWUXFWLRQV
 &ORWKHVGU\HULQVWDOODWLRQPXVWEHSHUIRUPHGE\DTXDOL¿HGLQVWDOOHU
 ,QVWDOOWKHFORWKHVGU\HUDFFRUGLQJWRWKHVHLQVWUXFWLRQVDQGLQ
DFFRUGDQFHZLWKORFDOFRGHV
 7KLVGU\HUPXVWEHH[KDXVWHGWRWKHRXWGRRUV
 8VHRQO\µULJLGPHWDOGXFWLQJIRUH[KDXVWLQJWKHFORWKHVGU\HUWR
WKHRXWGRRUV
 DO NOTLQVWDOODFORWKHVGU\HUZLWKÀH[LEOHSODVWLFGXFWLQJPDWHULDOV
,IÀH[LEOHPHWDOVHPLULJLGRUIRLOW\SHGXFWLVLQVWDOOHGLWPXVWEH
8/OLVWHGDQGLQVWDOOHGLQDFFRUGDQFHZLWKWKHLQVWUXFWLRQVIRXQG
LQConnecting The Dryer To House Vent RQSDJHRIWKLVPDQXDO
)OH[LEOHYHQWLQJPDWHULDOVDUHNQRZQWRFROODSVHEHHDVLO\FUXVKHG
DQGWUDSOLQW7KHVHFRQGLWLRQVZLOOREVWUXFWGU\HUDLUÀRZDQG
LQFUHDVHWKHULVNRI¿UH
 'RQRWLQVWDOORUVWRUHWKLVDSSOLDQFHLQDQ\ORFDWLRQZKHUHLWFRXOG
EHH[SRVHGWRZDWHUDQGRUZHDWKHU
 6DYHWKHVHLQVWUXFWLRQVInstallers:%HVXUHWROHDYHWKHVH
LQVWUXFWLRQVZLWKWKHFXVWRPHU
 ,QVWDOOWKHFORWKHVGU\HUDFFRUGLQJWRWKHPDQXIDFWXUHU·V
LQVWUXFWLRQVDQGORFDOFRGHV
NOTE: Installation and service of this dryer
requires basic mechanical and electrical
skills. It is your responsibility to contact
a quali¿ed installer to make the electrical
connections.
Installation
Instructions
Electric Dryer
04
Questions on Installation? Call: 800.GE.CARES (US)
RUYLVLWRXUZHEVLWHDWwww.GEAppliances.com (US)
BEFORE YOU BEGIN
Read these instructions completely and carefully.

IMPORTANT-6DYHWKHVHLQVWUXFWLRQV
IRUORFDOLQVSHFWRU·VXVH
 IMPORTANT-2EVHUYHDOOJRYHUQLQJ
FRGHVDQGRUGLQDQFHV
Note to Installer -%HVXUHWROHDYHWKHVH
LQVWUXFWLRQVZLWKWKHFXVWRPHU
 Note to Customer -.HHSWKHVHLQVWUXFWLRQV
ZLWK\RXU2ZQHU·V0DQXDOIRUIXWXUHUHIHUHQFH
 %HIRUHWKHROGGU\HULVUHPRYHGIURPVHUYLFHRU
GLVFDUGHGUHPRYHWKHGU\HUGRRU
 ,QVSHFWWKHGU\HUH[KDXVWRXWOHWDQGVWUDLJKWHQ
WKHRXWOHWZDOOVLIWKH\DUHEHQW
 6HUYLFHLQIRUPDWLRQDQGWKHZLULQJGLDJUDP
DUHORFDWHGLQWKHFRQWUROFRQVROH
 'RQRWDOORZFKLOGUHQRQRULQWKHDSSOLDQFH
&ORVHVXSHUYLVLRQRIFKLOGUHQLVQHFHVVDU\ZKHQ
WKHDSSOLDQFHLVXVHGQHDUFKLOGUHQ
 ,QVWDOOWKHGU\HUZKHUHWKHWHPSHUDWXUHLV
DERYH)IRUVDWLVIDFWRU\RSHUDWLRQRIWKH
GU\HUFRQWUROV\VWHP
 3URGXFWIDLOXUHGXHWRLPSURSHULQVWDOODWLRQ
LVQRWFRYHUHGXQGHUWKHZDUUDQW\
TOOLS YOU WILL NEED
SLIP JOINT PLIERS
FLAT BLADE SCREWDRIVER
PHILLIPS SCREWDRIVER
LEVEL
TOOLS YOU WILL NEED
GLOVES
SAFETY
GLASSES
DRYER POWER
CORD KIT
(NOT PROVIDED
WITH DRYER)
4" DUCT
CLAMPS (2)
OR
4" SPRING
CLAMPS (2)
EXHAUST
HOOD
3/4" STRAIN
RELIEF
UL RECOGNIZED
4" DIA. MET AL
ELBOW
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT (IF NEEDED.)
DUCT TAPE
UL RATED
120/240V,30A
WITH 3 OR 4 PRONGS.
IDENTIFY THE PLUG
TYPE AS PER THE
HOUSE RECEPTACLE
BEFORE PURCHASING
LINE CORD.
4” COVER PLATE (IF NEEDED
(KIT WE1M454)
234D1582P004 31-16224-2 03-12 GE
6WHS3UHSDUHWKH$UHDDQG([KDXVWIRU,QVWDOODWLRQRI
1HZ'U\HUVHHVHFWLRQ
6WHS&KHFNDQG(QVXUHWKH([LVWLQJ([WHUQDO([KDXVWLV
&OHDQVHHVHFWLRQDQG0HHWV$WWDFKHG,QVWDOODWLRQ
6SHFL¿FDWLRQVVHHVHFWLRQ
6WHS5HPRYHWKH)RDP6KLSSLQJ3DGVVHHVHFWLRQ
6WHS0RYHWKH'U\HUWRWKH'HVLUHG/RFDWLRQ
6WHS&RQQHFWWKH3RZHU6XSSO\VHHVHFWLRQ
6WHS&RQQHFWWKH([WHUQDO([KDXVWVHHVHFWLRQ
6WHS/HYHO<RXU'U\HUVHHVHFWLRQ
6WHS&KHFNWKH2SHUDWLRQRIWKH3RZHU6XSSO\9HQWLQJ
6WHS3ODFHWKH2ZQHU·V0DQXDODQGWKH,QVWDOODWLRQ
,QVWUXFWLRQVLQDORFDWLRQZKHUHWKH\ZLOOEHQRWLFHGE\WKH
RZQHU
)RU$OFRYHRU&ORVHW,QVWDOODWLRQVHHVHFWLRQ
)RU%DWKURRPRU%HGURRP,QVWDOODWLRQVHHVHFWLRQ
)RU0RELOHRU0DQXIDFWXUHG+RPHVHHVHFWLRQ
)RUJDUDJHLQVWDOODWLRQLIDOORZHGE\ORFDOFRGHVVHHVHFWLRQ
)RUVLGHRUERWWRPH[KDXVWVHHVHFWLRQ
Installation Instructions
2
Minimum Clearance Other Than Alcove or Closet Installation
0LQLPXPFOHDUDQFHWRFRPEXVWLEOHVXUIDFHVDQGIRUDLURSHQLQJDUHLQFOHDUDQFHERWKVLGHVDQGLQUHDU
&RQVLGHUDWLRQmustEHJLYHQWRSURYLGHDGHTXDWHFOHDUDQFHIRULQVWDOODWLRQDQGVHUYLFH
1 PREPARING FOR INSTALLATION
OF NEW DRYER
TIP: Install your dryer before installing your washer.
This will allow better access when installing dryer
exhaust.
REMOVING LINT FROM WALL
EXHAUST OPENING
Remove and discard existing plastic or metal foil
transition duct and replace with UL listed transition
duct.
2 ELECTRICAL CONNECTION
INFORMATION
WARNING - TO REDUCE THE RISK
OF FIRE, ELECTRICAL SHOCK AND PERSONAL
INJURY:
DO NOT USE AN EXTENSION CORD OR AN
ADAPTER PLUG WITH THIS APPLIANCE.
'U\HUPXVWEHHOHFWULFDOO\JURXQGHGLQDFFRUGDQFHZLWK
ORFDOFRGHVDQGRUGLQDQFHVRULQWKHDEVHQFHRIORFDO
FRGHVLQDFFRUGDQFHZLWKWKH1$7,21$/(/(&75,&$/
&2'($16,1)3$12
CONNECTING DRYER USING 4-WIRE
CONNECTION (MUST BE USED FOR
MOBILE HOME INSTALLATION)
NOTES: SInce January 1,1996, the National Electric code
requires that the new constructions utilize a 4-wire
connection to an electric dryer.
WARNING:Only a 4-conductor cord shall be
used when the appliance is installed in a location where
grounding through the neutral conductor is prohibited.
Grounding through the neutral is prohibited for the new
branch-circuit installations, mobile homes, recreational
vehicles, and areas where local codes prohibit
grounding through the neutral conduction.
7XUQRȺWKHFLUFXLWEUHDNHUVDPSRUUHPRYHWKH
GU\HU·VFLUFXLWIXVHDWWKHHOHFWULFDOER[
%HVXUHWKHGU\HUFRUGLVXQSOXJJHGIURPWKHZDOO
UHFHSWDFOH
5HPRYHWKHSRZHUFRUGFRYHUORFDWHGDWWKHORZHU
EDFN
5HPRYHDQGGLVFDUGJURXQGVWUDS.HHSWKHJUHHQ
JURXQGVFUHZIRUVWHS
,QVWDOOLQ8/UHFRJQL]HGVWUDLQUHOLHIWRSRZHUFRUG
HQWU\KROH%ULQJSRZHUFRUGWKURXJKVWUDLQUHOLHI
&RQQHFWSRZHUFRUGDVIROORZV
$&RQQHFWWKHKRWOLQHVWRWKHRXWHUVFUHZVRI
WKHWHUPLQDOEORFNPDUNHG/DQG/
%&RQQHFWWKHQHXWUDOZKLWHOLQHWRWKHFHQWHURI
WKHWHUPLQDOEORFNPDUNHG1
$WWDFKJURXQGZLUHRISRZHUFRUGZLWKWKHJUHHQ
JURXQGVFUHZKROHDERYHVWUDLQUHOLHIEUDFNHW7LJKWHQ
DOOWHUPLQDOEORFNVFUHZVVHFXUHO\
3URSHUO\VHFXUHSRZHUFRUGWRVWUDLQUHOLHI
5HLQVWDOOWKHFRYHU
L1
N
L2
RELOCATE GREEN
GROUND SCREW
HERE
STRAIN
RELIEF
BRACKET
GREEN OR
YELLOW WIRE
3/4", UL
RECOGNIZED
STRAIN RELIEF
HOT
WIRE
SCREWS
(3)
HOT
WIRE
COVER
NEUTRAL
(White)
REMOVE GROUND STRAP
AND DISCARD. KEEP GREEN
GROUND SCREW
4 #10 AWG MINIMUM COPPER
CONDUCTORS OR 120/240V 30A POWER
SUPPLY CORD KIT MARKED FOR USE
WITH DRYERS & PROVIDED WITH
CLOSED LOOP OR SPADE TERMINALS
WITH UPTURNED ENDS (NOT SUPPLIED).
INTERNAL DUCT
OPENING CHECK THA T EXHAUST
HOOD DAMPER OPENS
AND CLOSES FREE LY.
WALL
TILT THE DRYER SIDEWAYS
AND REMOVE THE FOAM
SHIPPING PADS BY
PULLING AT THE SIDES
AND BREAKING THEM
AWAY FROM THE DRYER
LEGS. BE SURE TO
REMOVE ALL OF THE
FOAM PIECES AROUND
THE LEGS.
ELECTRICAL REQUIREMENTS
7KLVGU\HUPXVWEHFRQQHFWHGWRDQLQGLYLGXDO
EUDQFKFLUFXLWSURWHFWHGE\WKHUHTXLUHGWLPHGHOD\
IXVHVRUFLUFXLWEUHDNHUV$IRXURUWKUHHZLUHVLQJOH
SKDVH9RU9+]DPSFLUFXLW
LVUHTXLUHG,IWKHHOHFWULFVXSSO\GRHVQRWPHHWWKH
DERYHVSHFL¿FDWLRQVWKHQFDOODOLFHQVHGHOHFWULFLDQ
GROUNDING INSTRUCTIONS
7KLVGU\HUPXVWEHFRQQHFWHGWRDJURXQGHGPHWDO
SHUPDQHQWZLULQJV\VWHPRUDQHTXLSPHQWJURXQGLQJ
FRQGXFWRUPXVWEHUXQZLWKWKHFLUFXLWFRQGXFWRUVDQG
FRQQHFWHGWRWKHHTXLSPHQWJURXQGLQJWHUPLQDORQWKH
DSSOLDQFH
WARNING: NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK.
Installation Instructions
3
CONNECTING DRYER USING 3-WIRE
CONNECTION
3-wire Connection
1RWIRUXVHLQ&DQDGD
'2127XVHIRU0RELOH+RPH,QVWDOODWLRQV
127IRUXVHRQQHZFRQVWUXFWLRQ
127IRUXVHRQUHFUHDWLRQDOYHKLFOHV
127IRUXVHLQDUHDVZKHUHORFDOFRGHVSURKLELW
JURXQGLQJWKURXJKWKHQHXWUDOFRQGXFWLRQ
7XUQRȺWKHFLUFXLWEUHDNHUVDPSRUUHPRYHWKH
GU\HU·VFLUFXLWIXVHDWWKHHOHFWULFDOER[
%HVXUHWKHGU\HUFRUGLVXQSOXJJHGIURPWKHZDOO
5HPRYHWKHSRZHUFRUGFRYHUORFDWHGDWWKHORZHU
EDFN
,QVWDOOLQ8/UHFRJQL]HGVWUDLQUHOLHIWRSRZHUFRUG
HQWU\KROH%ULQJSRZHUFRUGWKURXJKVWUDLQUHOLHI
&RQQHFWSRZHUFRUGDVIROORZV
$&RQQHFWWKHKRWOLQHVWRWKHRXWHUVFUHZVRI
WKHWHUPLQDOEORFNPDUNHG/DQG/
%&RQQHFWWKHQHXWUDOZKLWHOLQHWRWKHFHQWHU
RIWKHWHUPLQDOEORFNPDUNHG1
%HVXUHJURXQGVWUDSLVFRQQHFWHGWRQHXWUDOFHQWHU
WHUPLQDORIEORFNDQGWRJUHHQJURXQGVFUHZRQFDEL
QHWUHDU7LJKWHQDOOWHUPLQDOEORFNVFUHZVVHFXUHO\
3URSHUO\VHFXUHSRZHUFRUGWRVWUDLQUHOLHI
5HLQVWDOOWKHFRYHU
L1
L2
STRAIN RELIEF
BRACKET
3/4", UL
RECOGNIZED
STRAIN RELIEF
HOT
WIRE
HOT
WIRE
GROUND
STRAP
GREEN
GROUND
SCREW
NEUTRAL
(White)
SCREWS
(3)
IF REQUIRED, BY LOCAL CODE,
INSTALL EXTERNAL GROUND
(NOT PROVIDED) TO GROUNDED
METAL, COLD WATER PIPE, OR
OTHER ESTABLISHED GROUND
DETERMINED BY A QUALIFIED
ELECTRICIAN.
COVER
3 #10 AWG MINIMUM COPPER
CONDUCTORS OR 120/240V 30A POWER
SUPPLY CORD KIT MARKED FOR USE
WITH DRYERS & PROVIDED WITH CLOSED
LOOP OR SPADE TERMINALS WITH
UPTURNED ENDS (NOT SUPPLIED).
3 EXHAUST INFORMATION
EXHAUST SYSTEM CHECK LIST
HOOD OR WALL CAP
7HUPLQDWHLQDPDQQHUWRSUHYHQWEDFNGUDIWVRUHQWU\
RIELUGVRURWKHUZLOGOLIH
7HUPLQDWLRQVKRXOGSUHVHQWPLQLPDOUHVLVWDQFHWR
WKHH[KDXVWDLUÀRZDQGVKRXOGUHTXLUHOLWWOHRUQR
PDLQWHQDQFHWRSUHYHQWFORJJLQJ
NeverLQVWDOODVFUHHQLQRURYHUWKHH[KDXVWGXFW7KLV
FRXOGFDXVHOLQWEXLOGXS
:DOOFDSVPXVWEHLQVWDOOHGDWOHDVWLQDERYHJURXQG
OHYHORUDQ\RWKHUREVWUXFWLRQZLWKWKHRSHQLQJSRLQWHG
GRZQ
SEPARATION OF TURNS
)RUEHVWSHUIRUPDQFHVHSDUDWHDOOWXUQVE\DWOHDVWIW
RIVWUDLJKWGXFWLQFOXGLQJGLVWDQFHEHWZHHQODVWWXUQDQG
H[KDXVWKRRG
TURNS OTHER THAN 90º
2QHWXUQRIRUOHVVPD\EHLJQRUHG
7ZRWXUQVVKRXOGEHWUHDWHGDVRQHWXUQ
(DFKWXUQRYHUVKRXOGEHWUHDWHGDVRQHWXUQ
WARNING - IN CANADA AND IN
THE UNITED STATES, THE REQUIRED EX-
HAUST DUCT DIAMETER IS 4 IN (102mm). DO
NOT USE DUCT LONGER THAN SPECIFIED IN
THE EXHAUST LENGTH TABLE.
8VLQJH[KDXVWORQJHUWKDQVSHFL¿HGOHQJWKZLOO
,QFUHDVHWKHGU\LQJWLPHVDQGWKHHQHUJ\FRVW
5HGXFHWKHGU\HUOLIH
$FFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG
The correct exhaust installation is YOUR
RESPONSIBILITY. Problems due to incorrect
installation are not covered by the warranty.
5HPRYHDQGGLVFDUGH[LVWLQJSODVWLFRUPHWDOIRLO
WUDQVLWLRQGXFWDQGUHSODFHZLWK8/OLVWHGWUDQVLWLRQ
GXFW
7KHMAXIMUM ALLOWABLEGXFWOHQJWKDQGQXPEHURI
EHQGVRIWKHH[KDXVWV\VWHPGHSHQGVXSRQWKHW\SHRI
GXFWQXPEHURIWXUQVWKHW\SHRIH[KDXVWKRRGZDOO
FDSDQGDOOFRQGLWLRQVQRWHGEHORZ7KHPD[LPXP
GXFWOHQJWKIRUULJLGPHWDOGXFWLVVKRZQLQWKHWDEOH
EHORZ
EXHAUST LENGTH
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90º
Elb ows Rigid
Metal Rigid
Metal
90 Feet
60 Feet
45 Feet
35 Feet
25 Feet
0
1
2
3
4
60 Feet
45 Feet
35 Feet
25 Feet
15 Feet
Use only for sho rt
run installations
WARNING: NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK.


Product specificaties