Fujitsu ASHG12LMCA Handleiding

Fujitsu Airco ASHG12LMCA

Lees hieronder de 📖 handleiding in het Nederlandse voor Fujitsu ASHG12LMCA (8 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 80 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
En-1
Safety Precautions
To prevent personal injury, or property damage, read this section carefully before you use this product, and be sure to comply following safety
precautions.
Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classi ed as follows:
WARNING CAUTION
This mark warns of death or serious injury. This mark warns of injury or damage to property.
This mark denotes an action that is PROHIBITED. This mark denotes an action that is COMPULSORY.
WARNING
This product contains no user-serviceable parts. Always
consult authorized service personnel for repairing,
installation, and relocation of this product.
Improper installation or handling will cause leakage, electric
shock, or re.
In the event of a malfunction such as burning smell,
immediately stop operation of the air conditioner, and
disconnect all the power supply by turning off the electrical
breaker or disconnecting the power plug. Then consult
authorized service personnel.
Take care not to damage the power supply cable.
If it is damaged, it should only be replaced by authorized
service personnel.
In the event of refrigerant leakage, be sure to keep away
from re or any ammables, and consult authorized service
personnel.
In the event of a thunder storm or any prior sign of a lightning
strike, turn off the air conditioner via the remote controller,
and refrain from touching the product or the power source to
prevent any electrical hazards.
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not
play with the appliance.
Do not start or stop the operation of this product by inserting
or pulling out the power plug, or by turning on or off the
circuit breaker.
Do not use ammable gases near this product.
Do not expose yourself directly to the cooling air ow for
many hours.
Do not insert your ngers or any other objects into outlet
port, open panel, or intake grille.
Do not operate with wet hands.
CAUTION
Provide occasional ventilation during use.
Always operate this product with air lters installed.
Ensure that any electronic equipment is at least 1 m (40 in)
away from either the indoor unit or outdoor unit.
Disconnect all the power supply when you are not using this
product for extended periods.
After a long period of use, ensure to get the mounting of the
indoor unit checked to prevent this product from falling down.
The air ow direction and the room temperature should be
carefully considered when you use this product in a room
with infants, children, elderly or sick persons.
Do not place any other electrical products or household
belongings under this product.
Dripping condensation from this product might get them wet,
and may cause damage or malfunction of your property.
Do not expose this product directly to water.
Do not use this product for preservation of food, plants,
animals, precision equipment, art work, or other objects. This
may cause quality deterioration of those items.
Do not expose animals or plants to the direct air ow.
Do not drink the drainage from the air conditioner.
Do not pull the power supply cable.
Do not touch the aluminum ns of heat exchanger built-in
this product to avoid personal injury when you maintain the
unit.
Do not direct the air
ow at
replaces or heating apparatus.
Do not block or cover the intake grille and the outlet port.
Do not apply any heavy pressure to radiator ns.
Do not climb on, place objects on, or hang objects from this product.
PART No. 9333003047-04
[Original instructions]
Português E vIkλλη ά Italiano Español Français Deutsch English
Türkçe Русский
AIR CONDITIONER
Wall Mounted Type
OPERATING MANUAL
Before using this product, read these instructions thoroughly and keep this manual for future reference.
Contents
Safety Precautions ............................................................... 1
Indoor Unit Overview and Operations .................................. 2
Remote Controller Overview and Operations ....................... 3
Timer Operation.................................................................... 5
General Information on Operation ........................................ 5
Care and Cleaning................................................................ 6
Troubleshooting .................................................................... 8
This product contains uorinated greenhouse gases.
En-2 OPERATING MANUAL
1 Intake grille
Before starting operation, make sure that the intake grille has been
shut completely. Incomplete closing might have an effect on the
proper working or performance of the product.
2 MANUAL AUTO button
Use when you lost the remote controller or remote control malfunction
occurs.
Status Action Mode or operation
In operation Press more than 3 seconds. Stop
Stopping Press more than 3 seconds and
less than 10 seconds.
AUTO
Press more than 10 seconds.
(Only for servicing.*)
Forced cooling
After cleaning Press less than 3 seconds. Filter indicator reset
*:To stop forced cooling, press this button or Start/Stop button on the
remote controller.
3 Front panel
4 Vertical air ow direction louver
Each time you press “SET” button on the remote controller, the angle
of the vertical air ow direction louver moves as follows:
1
2
3
4
567
COOL or DRY mode HEAT mode
1 2 3 765
* *
4
*: Default setting in each mode.
Do not adjust by hand.
At the beginning of AUTO or HEAT mode, they may stay position 1
for a while for adjustment.
If you set the angle to position 4–7 for more than 30 minutes in
COOL or DRY mode, they automatically return to position 3.
In COOL or DRY mode, if the angle is set to position 4–7 for many hours,
condensation may be formed, and the drips may wet your property
.
5 Power diffuser
In conjunction with movement of the vertical air ow direction louver,
the angle of the power diffuser moves as follows:
Vertical air ow
direction louver
Power diffuser
3 765421
321 4
In SWING operation, power diffuser does not move.
6 Drain hose
7 Remote control signal receiver
CAUTION
For appropriate signal transmission between remote controller and
the indoor unit, keep the signal receiver away from following items
:
- Direct sunlight or other strong light
- Flat-panel television screen
In rooms with instantaneous uorescent lights, such as in-
verter type ones, the signal may not be transmitted properly. In
such a case, consult the store that you purchased the product
.
8 ECONOMY indicator (green)
Lights in ECONOMY operation and in 10 °C HEAT operation.
9 TIMER indicator (orange)
Lights in TIMER operation, and blinks slowly when the timer setting
error is detected.
As for the timer setting error, refer to “Auto-restart function” on page 5.
10 OPERATION indicator (green)
Lights in normal operation, and blinks slowly in automatic defrosting
operation.
6
1
3
4
5
8
9
10
11
13
2
12
7
11
Horizontal air ow direction louvers
CAUTION
Before you adjust the horizontal air ow direction, make sure that
the vertical air ow direction louver has been stopped completely
.
Adjust two knobs by hand.
See page 6
12
Air lter
See page 7
13
Air cleaning lters
Purify or deodorize the air, and provide fresh air ow.
Indoor unit accessories
Remote
controller
Batteries Air cleaning lters Filter holders
Remote controller
holder
Tapping screws
WARNING
Take care to prevent infants and young children from acciden-
tally swallowing the batteries.
Remote controller holder installation
321
Screws
Insert
Slide up
Indoor Unit Overview and Operations
En-3
AIR CONDITIONER Wall Mounted Type
OPERATING MANUAL
CAUTION
To prevent malfunction or damage of the remote controller:
- Place remote controller at where will not be exposed to
direct sunlight or excessive heat.
- Remove batteries if the product is not going to be used for
an extended period.
- Exhausted batteries must be removed immediately, and
be disposed according to the local laws and regulations of
your region.
If leaking battery uid comes in contact with your skin, eyes,
or mouth, immediately rinse with plenty of clean water, and
consult your physician.
Obstacles such as a curtain or wall between the remote
controller and the indoor unit may affect the appropriate
signal transmission.
Do not apply strong shocks to the remote controller.
Do not pour water on the remote controller.
Do not attempt to recharge dry batteries.
Do not use dry batteries that has been recharged.
Battery (R03/LR03/AAA × 2) loading and remote controller preparation
1
4
2
3
5
7
6
5 Press “CLOCK ADJUST” button to start clock setting.
6 Set the time by pressing “SELECT” button.
Each time you press the button, the value increases or
decreases 1 minute. With pressing and holding the button, the
value increasesor decreases 10 minutes.
7 Press the “CLOCK ADJUST” button again to complete the clock
setting.
Notes:
Use speci ed type of battery only.
Do not mix different types or new and used batteries together.
Batteries can be used about 1 year in ordinary use.
If the remote control range noticeably shortens, replace the
batteries, and press “RESET” button.
You can quickly start the operation with following 3 steps:
Remote Controller Overview and Operations
1 Start/Stop button
2 MODE button
Switches operation mode in following order.
AUTO COOL DRY FAN HEAT
Notes in HEAT mode:
At the beginning of the operation, the indoor unit operates at very
low fan speed for about 3–5 minutes for preparation, and then
switches to the selected fan speed.
Automatic defrosting operation overrides the heating operation when
it is necessary.
Note in COOL mode:
Indoor unit fan may stop from time to time to perform indoor-unit-
fan control for energy saving that enables power-saving operation by
stopping the rotation of the indoor unit fan when the outdoor unit is
stopped.
(continued)
In initial setting, this function is activated.
To inactivate the function, consult the installer or authorized service
personnel.
Even if the setting is changed, if the fan speed is set to “AUTO” in
COOL or DRY mode, this function still works to suppress the diffusion
of circulated indoor humidity.
3 SET TEMP. (temperature) buttons
Set desired temperature.
In COOL/DRY mode, the value needs to be set at lower temperature
than current room temperature, and in HEAT mode, the value needs
to be set at higher temperature than current room temperature.
Otherwise, corresponding operation mode does not start to work.
Temperature setting range
AUTO/COOL/DRY 18–30 °C
HEAT 16–30 °C
*:Temperature control is not available in FAN mode.
18
15
16
14
19
2
9
10
13
8
3
11
12 1
5
6
4
7
17


Product specificaties

Merk: Fujitsu
Categorie: Airco
Model: ASHG12LMCA
Kleur van het product: Wit
Timer: Ja
Soort: Splitssysteem
Air conditioner functies: Cooling,Dehumidifying,Heating
Seizoensgebonden rendement (koeling) (SEER): 7
Seasonal efficiency rating (verwarming) (SCOP) (gemiddeld stookseizoen): 4
Energie-efficiëntieklasse (verwarming) (gemiddelde stookseizoen): A+
Jaarlijks energieverbruik (koelen): 170 kWu
Jaarlijks energieverbruik (verwarming) (warmer stookseizoen): - kWu
Jaarlijks energieverbruik (verwarming) (gemiddelde stookseizoen): 1225 kWu
Energie-efficiëntieklasse (koeling): A++
Extern geluidsniveau: 50 dB
Intern geluidsniveau (hoge snelheid): 43 dB
Luchtstroom: 750 m³/uur
Koelcapaciteit in watt (opgegeven): 3400 W
Verwarmingscapaciteit in watt (opgegeven) (warmer stookseizoen): - W
Verwarmingscapaciteit in watt (opgegeven) (gemiddelde stookseizoen): 4000 W
Verwarmingscapaciteit in watt (opgegeven) (kouder stookseizoen): - W
Energieverbruik per uur (koeling): - kWu
Energieverbruik per uur (verwarming): - kWu
Breedte binnenunit: 840 mm
Diepte binnenunit: 203 mm
Hoogte binnenunit: 268 mm
Ontvochtiging capaciteit: 1.8 L/u
Koel capaciteit in watt (max): 3900 W
Verwarmingscapaciteit in watt (max): 5300 W
Koeling energie efficientie: 3.5
Verwarming energie efficientie: 3.92
Indoor unit type: Muur-montage
Indoor eenheid gewicht: 8500 g
Jaarlijks energieverbruik (verwarming) (kouder stookseizoen): - kWu
Ontwerpbelasting (koeling): - kW
Ontwerpbelasting (verwarming) (warmer stookseizoen): - kW
Ontwerpbelasting (verwarming) (gemiddelde stookseizoen): - kW
Ontwerpbelasting (verwarming) (kouder verwarmingsseizoen): - kW
Outdoor eenheid gewicht: 26000 g
Breedte buitenunit: 663 mm
Diepte buitenunit: 293 mm
Hoogte buiteneenheid: 535 mm
AC-ingangsspanning: 230 V
AC-ingangsfrequentie: 50 Hz
Energieverbruik (koelen) (max): 970 W
Energieverbruik (verwarmen) (max): 1020 W
Koelcapaciteit in watt (min): 900 W
Verwarmingscapaciteit in watt (min): 900 W
Timerduur (maximum): 24 uur

Heb je hulp nodig?

Als je hulp nodig hebt met Fujitsu ASHG12LMCA stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Fujitsu

Handleiding Airco

Nieuwste handleidingen voor Airco