Fujitsu Airstage AJYA90LALH Handleiding
Lees hieronder de 📖 handleiding in het Nederlandse voor Fujitsu Airstage AJYA90LALH (25 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 26 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/25
English
OUTDOOR UNIT
PART NO. 9378945357
Deutsch
AUßENGERÄT
TM
FrançaisEspañol
UNITÉ EXTÉRIEURE
UNIDAD EXTERIOR
Italiano
UNITÀ ESTERNA
ΕλληνικάPortuguês
ΕΞΩΤΕΡΙΚΉ ΜΟΝΆΔΑ
UNIDADE EXTERIOR
РусскийTürkçe
中 文
ВНЕШНИЙ МОДУЛЬ
DIŞ ÜNİTE
室外机
AJYA72LALH
AJYA90LALH
AJY108LALH
AJY126LALH
AJY144LALH
AJHA72LALH
AJHA90LALH
AJH108LALH
AJH126LALH
AJH144LALH
INSTALLATION MANUAL
For authorized service personnel only.
INSTALLATIONSANLEITUNG
Nur für autorisiertes Fachpersonal.
MANUEL D’INSTALLATION
MANUAL DE INSTALACIÓN
Pour le personnel agréé uniquement.
Únicamente para personal de servicio autorizado.
MANUALE DI INSTALLAZIONE
A uso esclusivo del personale tecnico autorizzato.
ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ
Μόνο για εξουσιοδοτημένο τεχνικό .προσωπικό
MANUAL DE INSTALAÇÃO
Apenas para técnicos autorizados.
РУКОВОДСТВО ПО УСТАНОВКЕ
Только для авторизованного обслуживающего .персонала
Yalnızca yetkili servis personeli için.
仅针对授权的专业维修人员。
MONTAJ KILAVUZU
安装说明书
[Original instructions]
En-1
1. SAFETY PRECAUTIONS
• Be sure to read this Installation manual thoroughly before installation
.
• The warnings and precautions indicated in this Installation manual contain impor-
tant information pertaining to your safety. Be sure to observe them.
• After installing the unit, perform a test run to make sure the unit operates normally.
Then, explain to the customer how to operate and maintain the unit.
• Please pass this Installation manual together with the Operating manual to the cus-
tomer.
Please ask the customer to keep the Operating manual and Installation manual at
hand for future reference during the moving or repair of the main unit.
WARNING
This mark indicates procedures which, if improperly
performed, might lead to the death or serious injury of the
user.
For installation purposes, be sure to use the parts supplied by the manufacturer or
other prescribed parts.
Using non-specifi ed parts will cause serious accidents such as falling unit, refriger-
ant leakage, water leakage, electric shock, and fi re.
Contents
1. SAFETY PRECAUTIONS ........................................................................................ 1
2. ABOUT THIS PRODUCT ......................................................................................... 2
2. 1. Precautions for using the R410A refrigerant ................................................. 2
2. 2. Special tools for R410A ................................................................................. 2
2. 3. Accessories .................................................................................................. 2
2. 4. Combinations ................................................................................................ 2
2. 5. Optional parts................................................................................................ 3
3. INSTALLATION WORK ............................................................................................ 3
3. 1. Selecting an installation location ................................................................... 3
3. 2. Drain processing ........................................................................................... 3
3. 3. Installation dimensions .................................................................................. 3
3. 4. Transportation the outdoor unit ..................................................................... 5
3. 5. Installing the unit ........................................................................................... 6
4. SYSTEM CONFIGURATION ................................................................................... 6
4. 1. System confi guration .................................................................................... 6
4. 2. Pipe selection................................................................................................ 7
4. 3. Protection of pipes ........................................................................................ 8
5. PIPE INSTALLATION ............................................................................................... 8
5. 1. Brazing ..........................................................................................................8
5. 2. Indoor unit pipe connections ......................................................................... 8
5. 3. Piping method ...............................................................................................8
5. 4. Multiple connections ..................................................................................... 9
6. ELECTRICAL WIRING ........................................................................................... 11
6. 1. The precautions of electrical wiring ............................................................. 11
6. 2. Wiring method ............................................................................................. 11
6. 3. Knockout hole ............................................................................................. 11
6. 4. Selecting power supply cable and breaker ................................................. 12
6. 5. Transmission line ........................................................................................ 12
6. 6. Wiring procedure......................................................................................... 13
6. 7. External input and external output .............................................................. 14
7. FIELD SETTING .................................................................................................... 15
7. 1. Field setting switches .................................................................................. 15
7. 2. DIP switch setting ....................................................................................... 15
7. 3. Rotary switch setting ................................................................................... 16
7. 4. Push button setting ..................................................................................... 17
7. 5. Signal amplifi er address setting .................................................................. 19
7. 6. Indoor unit address setting .......................................................................... 19
7. 7. Resistance measurement of transmission cable
(Measure with breaker OFF) ....................................................................... 20
8. PIPE INSTALLATION II .......................................................................................... 20
8. 1. Sealing test ................................................................................................. 20
8. 2. Vacuum process ......................................................................................... 20
8. 3. Additional charging ..................................................................................... 21
8. 4. Installing insulation ...................................................................................... 22
9. TEST RUN .............................................................................................................22
9. 1. Pre-test run check items ............................................................................. 22
9. 2. Test operation method ................................................................................ 22
9. 3. Checklist ..................................................................................................... 23
10. LED STATUS ......................................................................................................... 23
10. 1. Normal operation codes .............................................................................. 23
10. 2. Error codes ................................................................................................. 23
11. INFORMATION ...................................................................................................... 24
INSTALLATION MANUAL
PART NO. 9378945357
VRF system outdoor unit
To install a unit that uses the R410A refrigerant, use dedicated tools and piping
materials that have been manufactured specifi cally for R410A use.
Because the pressure of the R410A refrigerant is approximately 1.6 times higher
than the R22, failure to use dedicated piping material or improper installation can
cause rupture or injury.
It will also cause serious accidents such as refrigerant leakage, water leakage,
electric shock, and fi re.
Do not use this equipment with air or any other unspecifi ed refrigerant in the refrig-
erant lines.
Excess pressure can cause a rupture.
Be sure to install the unit as prescribed, so that it can withstand earthquakes and
typhoons or other strong winds.
Improper installation can cause the unit to topple or fall, or other accidents
.
Ensure that the outdoor unit is securely installed at a place that can withstand the
weight of the unit.
Improper installation will cause injuries caused by falling unit.
If there is a refrigerant leakage, make sure that it does not exceed the concentration
limit.
If a refrigerant leakage exceeds the concentration limit, it can lead to accidents
such as oxygen starvation.
If a refrigerant leakage occurs during operation, immediately vacate the premises
and thoroughly ventilate the area.
If the refrigerant is exposed to fi re, it will create a hazardous gas.
Electrical work must be performed in accordance with this Installation manual by a
person certifi ed under the national or regional regulations. Be sure to use a dedi-
cated circuit for the unit.
An insuffi cient power supply circuit or improperly performed electrical work can
cause serious accidents such as electric shock or fi re.
For wiring, use the prescribed type of cables, connect them securely, making sure
that there are no external forces of the cables applied to the terminal connections.
Improperly connected or secured cables can cause serious accidents such as
overheating the terminals, electric shock, or fi re.
Do not turn ON the power until all work has been completed.
Turning ON the power before the work is completed can cause serious accidents
such as electric shock or fi re.
After the installation, make sure there is no refrigerant leakage.
If the refrigerant leaks into the room and becomes exposed to a source of fi re such
as a fan heater, stove, or burner, it will create a hazardous gas.
Use a wall hole pipe. Otherwise, it may cause a short circuit.
Do not place the outdoor unit near the handrail of the balcony.
Children may climb onto the outdoor unit, lean over the handrail and fall over.
Use only a specifi ed power cable. Poor connection, poor insulation, and exceeding the
allowable current will lead to electric shock and fi re
.
Attach the connecting cables securely to the terminal. Or secure it fi rmly with a "wir-
ing suppressor".
Loose connection will lead to malfunction, electric shock, and fi re.
Install a breaker to cut off all AC main current at the same time.
If you do not install a breaker, it may cause electric shock and fi re.
During installation, make sure that the refrigerant pipe is attached fi rmly before you
run the compressor.
Do not operate the compressor under the condition of refrigerant piping not at-
tached properly with 2-way or 3-way valve open. This may cause abnormal pres-
sure in the refrigeration cycle that leads to rupture and even injury.
During the pump-down operat mpressor is turned off ion, make sure that the co
before you remove the refrigerant piping. Do not remove the connection pipe while
the compressor is in operation with 2-way or 3-way valve open. This may cause
abnormal pressure in the refrigeration cycle that leads to breakage and even injury.
If there is a possibility of touching the fan during maintenance, make sure to turn
OFF the power before implementing the maintenance. Even if operations are
suspended, the fan of outdoor unit sometimes rotates, so if the fan rotates suddenly
while in contact with you may cause serious injury.
CAUTION
This mark indicates procedures which, if improperly
performed, might possibly result in personal harm to the
user, or damage to property.
This unit must be installed by qualifi ed personnel with a capacity certifi cate for
handling refrigerant fl uids. Refer to regulation and laws in use on installation place.
The installation must be carried out in compliance with regulations in force in the
place of installation and the installation instructions of the manufacturer.
This unit is part of a set constituting an air conditioner. It must not be installed alone
or with non-authorized by the manufacturer.
This unit contains no user-serviceable parts. Always consult authorized service
personnel to repairs.
When moving, consult authorized service personnel for disconnection and installa-
tion of the unit.
• Obtain the distribution network operator's agreement about the power capacity
of the power supply system, specifi cation of the cable and the harmonic current,
and etc. when you connect the outdoor unit with the power supply.
• This unit must be connected to a power supply with impedance of 0.33 ohm and
below. If the power supply does not satisfy this requirement, please consult the
power supplier.
• This product is intended for professional use.
Be sure to use a dedicated power circuit.
Never use a power supply shared by another appliance.
En-2
Do not install the unit in the following areas:
• Area with high salt content, such as at the seaside.
It will deteriorate metal parts, causing the parts to fall or the unit to leak water.
• Area fi lled with mineral oil or containing a large amount of splashed oil or
steam, such as a kitchen.
It will deteriorate plastic parts, causing the parts to fall or the unit to leak
water.
• Area that generates substances that adversely affect the equipment, such as
sulfuric gas, chlorine gas, acid, or alkali.
It will cause the copper pipes and brazed joints to corrode, which can cause
refrigerant leakage.
• Area containing equipment that generates electromagnetic interference.
It will cause the control system to malfunction, preventing the unit from oper-
ating normally.
• Area that can cause combustible gas to leak, contains suspended carbon
fi bers or fl ammable dust, or volatile infl ammables such as paint thinner or
gasoline.
If gas leaks and settles around the unit, it can cause a fi re.
• Avoid installing the unit at places where it will come into contact with animals’
urine or ammonia.
The units are not explosion proof and therefore should not be installed in explosive
atmosphere.
Do not use the unit for special purposes, such as storing food, raising animals,
growing plants, or preserving precision devices or art objects. It can degrade the
quality of the preserved or stored objects.
Ground the unit. Do not connect the ground wire to a gas pipe, water pipe, lightning
rod, or a telephone ground wire. Improper grounding may cause electric shock.
Perform draining for the unit according to the Installation manual. Check that the
water is properly drained.
If the drain processing is improperly installed, water may drip down from the unit,
wetting the furniture.
Do not touch the fi ns with bare hands.
Be sure not to start or stop the operation of air conditioning with power breaker.
Otherwise, it may cause malfunction or water leakage.
When setting it up near the equipment that generates electromagnetic waves and
the equipment that generates the higher harmonics wave, be sure to take measures
against noise. Otherwise, it may cause malfunction or failure.
When energizing to the crankcase heater, please turn on the power 12 hours or
earlier before operation begins. When the energizing time is short, it may cause
failure. Besides, please do not turn off power during the busy season.
Children should be monitored to ensure they do not play with the device.
This product is not intended to be used by people (including children) with physical,
sensory or mental disability, or persons lacking experience or knowledge unless
they have been given by the through a person responsible for their safety, supervi-
sion or instruction concerning the use of the device.
2. ABOUT THIS PRODUCT
2. 1. Precautions for using the R410A refrigerant
Pay careful attention to the following points :
Since the working pressure is 1.6 times higher than that of R22 models, some of the
piping and installation and service tools are special. (See the table in the SPECIAL
TOOLS FOR R410A section.)
Especially, when replacing a conventional refrigerant (other than R410A) model with
a new refrigerant R410A model, always replace the conventional piping and fl are
nuts with the R410A piping and fl are nuts.
Models that use refrigerant R410A have a different charging port thread diameter
to prevent erroneous charging with R22, R407C and for safety. Therefore, check
beforehand. [The charging port thread diameter for R410A is 1/2 UNF 20 threads
per inch.]
Be more careful than the installation of the refrigerant (other than R410A) models,
not to enter foreign matters (oil, water, etc.) and other refrigerant into the piping.
Also, when storing the piping, securely seal the openings by pinching, taping, etc.
When charging the refrigerant, take into account the slight change in the composi-
tion of the gas and liquid phases, and always charge from the liquid phase side
whose composition is stable.
2. 2. Special tools for R410A
Tool name Contents of change for R22 tool
Gauge manifold
Pressure is huge and cannot be measured with a conven-
tional (R22) gauge. To prevent erroneous mixing of other
refrigerants, the diameter of each port has been changed.
It is recommended to use a gauge manifold with a high
pressure display range -0.1 to 5.3 MPa and a low pressure
display range -0.1 to 3.8 MPa.
Charging hose To increase pressure resistance, the hose material and
base size were changed.
Tool name Contents of change for R22 tool
Vacuum pump
A conventional (R22) vacuum pump can be used by install-
ing a vacuum pump adapter.
• A conventional vacuum pump can be used by installing a
vacuum pump adapter.
• Be sure that the pump oil does not back fl ow into the sys-
tem. Use one capable for vacuum suction of -100.7kPa
(5 Ton, -755mmHg).
Gas leakage detec-
tor Special gas leakage detector for HFC refrigerant R410A.
2. 3. Accessories
Use connecting parts as required.
Do not throw away the connecting parts until the installation has been complete.
Name and shape Q’ty Application
Specifi cations
manual
1
—
Installation
manual
1
(This book)
Joint pipe A
1
For connecting gas pipe
(Straight type)
Joint pipe B
1
For connecting gas pipe
(L type)
Cable tie
4
For binding power cable and transmis-
sion cable
Grommet edging
2
For power supply cable and connec-
tion cable installation.
Attach to the knockout hole.
2. 4. Combinations
A maximum of 3 outdoor units can be connected to 1 refrigerant system.
The combination of outdoor units per refrigerant system and the number of indoor units
that can be connected are as follows:
Outdoor Unit
Model Name Nominal System Capacity (HP)
AJ A72LALH 8
AJ A90LALH 10
AJ 108LALH 12
AJ 126LALH 14
AJ 144LALH 16
Installation space combination
Combination (HP) 8 10 12 14 16 18 20 22 24 26 28
Outdoor Unit 1 (HP) 8 10 12 14 16 10 12 12 12 14 16
Outdoor Unit 2 (HP) – – – – – 8 8 10 12 12 12
Outdoor Unit 3 (HP) –––––––––––
Maximum Connectable
Indoor Unit 15 16 17 21 24 32 32 32 35 39 42
Combination (HP) 30 32 34 36 38 40 42 44 46 48
Outdoor Unit 1 (HP) 16 16 12 12 14 16 16 16 16 16
Outdoor Unit 2 (HP) 14 16 12 12 12 12 14 16 16 16
Outdoor Unit 3 (HP) – – 10 12 12 12 12 12 14 16
Maximum Connectable
Indoor Unit 45 48 48 48 48 48 48 48 48 48
When connecting outdoor units, install the outdoor unit with the largest nominal system capac-
ity nearest to the refrigerant pipe and indoor unit, followed by those with lesser nominal system
capacities. (Outdoor unit 1 ≥ Outdoor unit 2 ≥ Outdoor unit 3)
Product specificaties
Merk: | Fujitsu |
Categorie: | Airco |
Model: | Airstage AJYA90LALH |
Heb je hulp nodig?
Als je hulp nodig hebt met Fujitsu Airstage AJYA90LALH stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Airco Fujitsu
10 December 2024
6 November 2024
2 November 2024
25 September 2024
3 September 2024
3 September 2024
3 September 2024
3 September 2024
3 September 2024
3 September 2024
Handleiding Airco
- Airco Electrolux
- Airco Bosch
- Airco Candy
- Airco Samsung
- Airco Delonghi
- Airco Panasonic
- Airco LG
- Airco AEG
- Airco Bauknecht
- Airco BEKO
- Airco Daewoo
- Airco Grundig
- Airco Honeywell
- Airco Inventum
- Airco Karcher
- Airco Medion
- Airco Remeha
- Airco Siemens
- Airco Toshiba
- Airco Unold
- Airco Vaillant
- Airco Whirlpool
- Airco Zanussi
- Airco Zibro
- Airco Adler
- Airco Airwell
- Airco Akai
- Airco Amana
- Airco Amcor
- Airco Apc
- Airco Arcelik
- Airco Argo
- Airco Balay
- Airco Bartscher
- Airco Bavaria
- Airco Be Cool
- Airco Bestron
- Airco Blaupunkt
- Airco Blumfeldt
- Airco Bodin
- Airco Bomann
- Airco Brandt
- Airco D-Let
- Airco Daikin
- Airco Daitsu
- Airco Defy
- Airco Dimplex
- Airco Dometic
- Airco Domo
- Airco Duracraft
- Airco Duux
- Airco Easy Home
- Airco Eco-De
- Airco Eden
- Airco Edgestar
- Airco Edy
- Airco Einhell
- Airco Emerio
- Airco Emerson
- Airco Eurom
- Airco Everglades
- Airco Evolar
- Airco Exquisit
- Airco Fairland
- Airco Ferroli
- Airco Finlux
- Airco Firstline
- Airco Fral
- Airco Frigidaire
- Airco Frilec
- Airco Fronius
- Airco Fuave
- Airco Fuji Electric
- Airco G3 Ferrari
- Airco GE
- Airco General Electric
- Airco GlobalTronics
- Airco Gorenje
- Airco Gree
- Airco Gutfels
- Airco H.Koenig
- Airco Haier
- Airco Hisense
- Airco Hitachi
- Airco Holland Electro
- Airco Home Electric
- Airco Hotpoint
- Airco Hotpoint-Ariston
- Airco HQ
- Airco Hyundai
- Airco Iceberg
- Airco Innoliving
- Airco Insignia
- Airco Itho
- Airco Kalorik
- Airco Kelvinator
- Airco Kenmore
- Airco Klarstein
- Airco Koenic
- Airco Kogan
- Airco Korona
- Airco Lanaform
- Airco Lavorwash
- Airco Livington
- Airco Livoo
- Airco Logik
- Airco Maiko
- Airco Manta
- Airco Master
- Airco Maxicool
- Airco Meaco
- Airco Meireles
- Airco Melissa
- Airco Mesko
- Airco Mestic
- Airco Midea
- Airco Mistral
- Airco Mitsubishi
- Airco Moa
- Airco MPM
- Airco MundoClima
- Airco Nabo
- Airco Nedis
- Airco Philco
- Airco Prem-i-air
- Airco Primo
- Airco Princess
- Airco Profile
- Airco Progress
- Airco Proklima
- Airco Proline
- Airco Protector
- Airco Qlima
- Airco RCA
- Airco REMKO
- Airco Rotel
- Airco Rowenta
- Airco Royal Sovereign
- Airco Russell Hobbs
- Airco Sanyo
- Airco Sauber
- Airco Saunier Duval
- Airco Sencor
- Airco Sencys
- Airco Sharp
- Airco Sigma
- Airco SMC
- Airco Sonnenkonig
- Airco SPT
- Airco Starlyf
- Airco Stirling
- Airco Suntec
- Airco Tarrington House
- Airco Taurus
- Airco TCL
- Airco Team
- Airco Technisat
- Airco Teco
- Airco Tectro
- Airco Telefunken
- Airco Termozeta
- Airco Theben
- Airco Thomson
- Airco Tomado
- Airco Tosot
- Airco Toyotomi
- Airco Trilec
- Airco Tristar
- Airco Tronix
- Airco Trotec
- Airco Truma
- Airco Ufesa
- Airco Vestel
- Airco Vivax
- Airco Waeco
- Airco Westinghouse
- Airco White Knight
- Airco Whynter
- Airco Woods
- Airco Zelmer
- Airco Jocca
- Airco Jocel
- Airco Just Fire
- Airco OK
- Airco Olimpia Splendid
- Airco OneConcept
- Airco Oregon Scientific
- Airco Ozito
- Airco Becken
- Airco Black And Decker
- Airco Camry
- Airco Clatronic
- Airco Concept
- Airco ECG
- Airco Elba
- Airco Essentiel B
- Airco Guzzanti
- Airco Heinner
- Airco Khind
- Airco Orbegozo
- Airco Profilo
- Airco Trisa
- Airco Vox
- Airco Wilfa
- Airco Anslut
- Airco Kunft
- Airco Soler And Palau
- Airco Conrad
- Airco Ansonic
- Airco Aspes
- Airco Comfee
- Airco Corberó
- Airco Danby
- Airco Equator
- Airco Esatto
- Airco IFB
- Airco Infiniton
- Airco Koldfront
- Airco Listo
- Airco Orima
- Airco Svan
- Airco Ardes
- Airco Eldom
- Airco Premium
- Airco Teesa
- Airco Alpatec
- Airco ElectriQ
- Airco Heylo
- Airco HTW
- Airco Prime3
- Airco Avidsen
- Airco SereneLife
- Airco DCG
- Airco Kubo
- Airco Malmbergs
- Airco Challenge
- Airco Calor
- Airco Riffel
- Airco Broan
- Airco RIDGID
- Airco KDK
- Airco Bimar
- Airco Climadiff
- Airco Tripp Lite
- Airco Mabe
- Airco Equation
- Airco Godrej
- Airco Milectric
- Airco Orava
- Airco Simplicity
- Airco Cecotec
- Airco Baxi
- Airco Thermex
- Airco Keystone
- Airco Sanus
- Airco Carrier
- Airco Furrion
- Airco Rinnai
- Airco Carson
- Airco Artrom
- Airco Carrefour Home
- Airco Céliera
- Airco Commercial Cool
- Airco Coolix
- Airco Hokkaido
- Airco Kibernetik
- Airco Norpole
- Airco Senville
- Airco SHE
- Airco CyberPower
- Airco Perfect Aire
- Airco Be Quiet!
- Airco Ariston Thermo
- Airco Element
- Airco Dantherm
- Airco Argoclima
- Airco DEXP
- Airco Chigo
- Airco Elgin
- Airco Evapolar
- Airco EcoFlow
- Airco Liebert
- Airco Avalon Bay
- Airco NewAir
- Airco Braemar
- Airco ActronAir
- Airco Klimaire
- Airco Consul
- Airco SEEGER
- Airco LERAN
- Airco Friedrich
- Airco Aerian
- Airco Polocool
- Airco Convair
- Airco Companion
- Airco Volteno
- Airco Arcoaire
- Airco AFINTEK
- Airco Brivis
- Airco MRCOOL
- Airco B-Air
- Airco Monzana
- Airco Kaden
- Airco Geist
- Airco GoldAir
- Airco Avallon
- Airco Ravanson
- Airco Create
- Airco Columbia Vac
- Airco TURBRO
- Airco House & Luft
- Airco Daizuki
- Airco Bonaire
- Airco Evapcool
- Airco Vostok
- Airco American Comfort
- Airco Ocean Breeze
- Airco Quirky
- Airco Krone
- Airco KwiKool
- Airco Big Ass Fans
- Airco Arctic King
- Airco Omega Altise
- Airco Climachill
- Airco Heat Controller
- Airco Luma Comfort
- Airco AireMax
- Airco Kaco
- Airco Middle Atlantic
- Airco Goodwe
- Airco Swegon
- Airco InAlto
- Airco JHS
- Airco FREONIC
- Airco ARCTIC WIND
- Airco Electroline
- Airco BLUEPALM
- Airco KuulAire
- Airco Cool-Space
- Airco BOSFOR
- Airco Aconatic
- Airco VänEE
- Airco Mayer
- Airco Yamazen
- Airco Corona
- Airco Symphony
- Airco Soler & Palau
- Airco Universal Blue
Nieuwste handleidingen voor Airco
21 December 2024
20 December 2024
18 December 2024
18 December 2024
18 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024