Fujitsu ABTG54LRTA Handleiding

Fujitsu Airco ABTG54LRTA

Lees hieronder de 📖 handleiding in het Nederlandse voor Fujitsu ABTG54LRTA (20 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 17 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/20
AIR CONDITIONER
Ceiling Suspension Type
Indoor Unit
ABTG54LR
OPERATING MANUAL
KEEP THIS MANUAL FOR FUTURE REFERENCE
FUJITSU GENERAL LIMITED PART NO. 9374379576
2
MDo not attempt to install this air conditioner by yourself.
MThis unit contains no user-serviceable parts. Always consult authorized service person-
nel for repairs.
M
When moving, consult authorized service personnel for disconnection and installation of
the air conditioner.
M
Do not become excessively chilled by staying for many hours in the direct cooling airflow.
MDo not insert fingers or objects into the outlet port or intake grilles.
MDo not start and stop air conditioner operation by disconnecting the power supply cable
and so on.
MTake care not to damage the power supply cable.
MIn the event of a malfunction (burning smell, etc.), immediately stop operation, turn off
the electrical breaker, and consult authorized service personnel.
M
If the power supply cable of this appliance is damaged, it should only be replaced by the au-
thorized service personnel, since special purpose tools and specified cable are required.
MIn the event of the refrigerant leakage, be sure to keep it away from fire or any am-
mables. (consult an authorized service personnel)
MProvide occasional ventilation during use.
MDo not direct air flow at fireplaces or heating apparatus.
MDo not climb on, or place objects on, the air conditioner.
MDo not hang objects from the indoor unit.
MDo not set flower vases or water containers on top of air conditioners.
MDo not expose the air conditioner directly to water.
MDo not operate the air conditioner with wet hands.
MDo not pull power supply cable.
MTurn off power source when not using the unit for extended periods.
MAlways turn off the electrical breaker whenever cleaning the air conditioner or changing
the air filter.
MConnection valves become hot during Heating; handle with care.
MWhen restarting after a long period of disuse in the winter, turn the power switch on at
least 12 hours before starting the unit.
MCheck the condition of the installation stand for damage.
MDo not place animals or plants in the direct path of the air flow.
MDo not drink the water drained from the air conditioner.
M
Do not use in applications involving the storage of foods, plants or animals, precision equip-
ment, or art works.
MDo not apply any heavy pressure to radiator fins.
MOperate only with air filters installed.
MDo not block or cover the intake grille and outlet port.
MEnsure that any electronic equipment is at least 1 m away from either the indoor or
outdoor units.
MAvoid installing the air conditioner near a fireplace or other heating apparatus.
M
When installing the indoor and outdoor units, take precautions to prevent access by infants.
MDo not use inflammable gases near the air conditioner.
CONTENTS
SAFETY PRECAUTIONS ....................................... 2
FEATURES AND FUNCTIONS .............................. 3
NAME OF PARTS .................................................. 4
PREPARATION ...................................................... 6
OPERATION ........................................................... 7
TIMER OPERATION .............................................. 9
SLEEP TIMER OPERATION ................................ 10
MANUAL AUTO OPERATION .............................. 10
ADJUSTING THE DIRECTION OF AIR CIRCULATION
....11
SWING OPERATION ........................................... 12
ECONOMY OPERATION ..................................... 12
10 °C HEAT OPERATION .................................... 13
SELECTING THE REMOTE
CONTROLLER SIGNAL CODE ........................... 13
CLEANING AND CARE ........................................ 14
TROUBLESHOOTING ......................................... 15
OPERATING TIPS ................................................ 16
TEMPERATURE AND HUMIDITY RANGE .......... 17
DANGER
CAUTION
SAFETY PRECAUTIONS
MBefore using the appliance, read these “PRECAUTIONS” thoroughly and operate in the correct way.
MThe instructions in this section all relate to safety; be sure to maintain safe operating conditions.
M“DANGER”, “WARNING” and “CAUTION” have the following meanings in these instructions:
DANGER This mark indicates procedures which, if improperly performed, are most likely to
result in the death or serious injury to the user or service personnel.
WARNING This mark indicates procedures which, if improperly performed, might lead to the
death or serious injury of the user or service personnel.
CAUTION This mark indicates procedures which, if improperly performed, might possibly result
in personal harm to the user, or damage to property.
3
FEATURES AND FUNCTIONS
OEnergy saving and Comfortable function
INVERTER
At the start of operation, large amount of power is used to
bring the room quickly to the desired temperature. Afterwards,
the unit automatically switches to a low power setting for eco-
nomic and comfortable operation.
ECONOMY OPERATION
When ECONOMY operation mode is operated, the room tempera-
ture will be little higher than the set-temp under cooling mode and
lower than set-temp under heating mode. Therefore, the ECONO-
MY mode is able to save more energy than other normal mode.
OMNI-DIRECTIONAL AIR FLOW
(SWING OPERATION)
3-dimensional control over air direction swing is possible through
dual use of both an up/down air direction swing and right/left air
direction swing. Since up/down air direction flaps operate auto-
matically according to the operating mode of the unit, it is pos-
sible to set air direction based on the operating mode.
SUPER QUIET OPERATION
When the FAN button is used to select QUIET, the indoor unit
begins super quiet operation; the indoor unit’s airflow is re-
duced to produce quieter operation.
AUTO CHANGEOVER
The operation mode (cooling, dry, heating) is switched auto-
matically to maintain the set temperature, and the temperature
is kept constant at all times.
10 °C HEAT OPERATION
The room temperature can be maintained at 10°C so as to
prevent the room temperature from falling too far.
OConvenient function
PROGRAM TIMER
The program timer allows you to integrate OFF timer and ON
timer operations in a single sequence. The sequence can in-
volve 1 transition from OFF timer to ON timer, or from ON
timer to OFF timer, within a 24 hour period.
SLEEP TIMER
When the SLEEP timer button is pressed during heating mode,
the air conditioner’s thermostat setting is gradually lowered dur-
ing the period of operation; during cooling or dry mode, the ther-
mostat setting is gradually raised during the period of operation.
When the set time is reached, the unit automatically turns off.
OClean function
REMOVABLE AIR FILTER
The indoor unit’s air filter can be removed for easy cleaning
and maintenance.
MILDEW-RESISTANT FILTER
The air filter has been treated to resist mildew growth, thus
allowing cleaner use and easier care.
ORemote controller
WIRELESS REMOTE CONTROLLER
The wireless remote controller allows convenient control of air
conditioner operation.
WIRED REMOTE CONTROLLER (OPTION)
The optional wired remote controller can be used.
When you use remote controller, there are following different
points as compared with using wireless remote controller.
[The additional functions for wired ones]
• Weekly timer
• Temperature set back timer
And you can use both wired and wireless remote controller
simultaneously.
(But function is limited)
When the restricted functions on the remote controller are
used, beeping sound will be heard, OPERATION, TIMER and
the 3rd lamp of the indoor unit will flash.
[The restricted functions for wireless ones]
• SLEEP timer
• TIMER (ON timer, OFF timer and program timer)
• 10 °C HEAT operation
SAFETY PRECAUTIONS
MThis appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
MIf you see lightning or hear thunder, there might be a lightning strike. To prevent electric
shock hazard, turn off the air conditioner by using the remote controller, and do not
touch the unit or the power plug during thunderstorm.
MDo not place any other electrical products or household belongings under indoor unit or
outdoor unit. Dripping condensation from the unit might get them wet, and may cause
damage or malfunction of your property.
MKeep clean and tidy around the outdoor unit, and do not place the things around it. If it is
covered with fallen leaves, there could be an infiltration of small animals or insects whose
contact with the internal electrical components leads to the product malfunction.
MDo not stand on unstable steps when operating or cleaning the air conditioner. It may
overturn and can cause the injury.
CAUTION


Product specificaties

Merk: Fujitsu
Categorie: Airco
Model: ABTG54LRTA

Heb je hulp nodig?

Als je hulp nodig hebt met Fujitsu ABTG54LRTA stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Fujitsu

Handleiding Airco

Nieuwste handleidingen voor Airco