Fuji Electric AGF14UI Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Fuji Electric AGF14UI (21 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 3 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/21
KEEP THIS MANUAL FOR FUTURE REFERENCE
DIESE ANLEITUNG BITTE SORGFÄLTIG AUFBEWAHREN
CONSERVEZ CE MODE D’EMPLOI AFIN DE POUVOIR VOUS Y RÉFÉRER ULTÉRIEUREMENT
GUARDE ESTE MANUAL PARA PODERLO CONSULTAR EN EL FUTURO
CONSERVARE QUESTO MANUALE PER OGNI EVENTUALE FUTURO RIFERIMENTO
ΚΡΑΤΗΣΤΕ ΕΓΧΕΙΡΙΔΙΟ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΤΟ ΑΝΑΦΟΡΑ
GUARDE ESTE MANUAL PARA CONSULTA POSTERIOR
СОХРАНИТЕ ЯЩЕЕ РУКОВОДСТВО ДЛЯ БУДУЩИХ ССЫЛОК НАСТО
BU KILAVUZU, DAHA SONRA BA VURMAK ÜZERE SAKLAYINŞ
OPERATING MANUAL
BEDIENUNGSANLEITUNG
MODE D’EMPLOI
MANUAL DE FUNCIONAMIENTO
MANUALE DI ISTRUZIONI
ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ
MANUAL DE INSTRUÇÕES
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
KULLANIM K TABIİ
PART No. 9378532052
AIR CONDITIONER
FLOOR TYPE
EnglishDeutschFrançaisEspañolItalianoE vIkλλη άPortuguêsРусскийTürkçe
En-1
Do not attempt to install this air conditioner by yourself.
This unit contains no user-serviceable parts. Always consult authorized service personnel for repairs.
When moving, consult authorized service personnel for disconnection and installation of the unit.
Do not become excessively chilled by staying for lengthy periods in the direct cooling air ow.
Do not insert anything into the Air ow direction.
Do not start and stop air conditioner operation by disconnecting the power supply cord.
Take care not to damage the power supply cord.
In the event of a malfunction (burning smell, etc.), immediately stop operation, disconnect the power
supply plug, and consult authorized service personnel.
If the power supply cord of this appliance is damaged, it should only be replaced by the authorized ser-
vice personal, since special purpose tools and speci ed cord are required.
In the event of refrigerant leakage, be sure to keep away from re or any ammables. (consult an autho-
rized service personnel)
Provide occasional ventilation during use.
Do not direct air ow at replaces or heating apparatus.
Do not climb on, or place objects on, the air conditioner.
Do not hang objects from the indoor unit.
Do not set ower vases or water containers on top of air conditioners.
Do not expose the air conditioner directly to water.
Do not operate the air conditioner with wet hands.
Do not pull power supply cord.
Turn off power source when not using the unit for extended periods.
Check the condition of the installation stand for damage.
Do not place animals or plants in the direct path of the air ow.
Do not drink the water drained from the air conditioner.
Do not use in applications involving the storage of foods, plants or animals, precision equipment, or art
works.
Connection valves become hot during Heating; handle with care.
Do not apply any heavy pressure to radiator ns.
Operate only with air lters installed.
Do not block or cover the intake grille and outlet port.
Ensure that any electronic equipment is at least 1 m away from either the indoor or outdoor units.
Avoid installing the air conditioner near a replace or other heating apparatus.
When installing the indoor and outdoor unit, take precautions to prevent access to infants.
Do not use in ammable gases near the air conditioner.
Do not sit and place anything on the unit.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the appliance.
WARNING!
CAUTION!
SAFETY PRECAUTIONS
Before using the appliance, read these “PRECAUTIONS” thoroughly and operate in the correct way.
The instructions in this section all relate to safety; be sure to maintain safe operating conditions.
“WARNING” and “CAUTION” have the following meanings in these instructions:
WARNING!
CAUTION!
This mark indicates procedures which, if improperly performed, might lead to the
death or serious injury of the user.
This mark indicates procedures which, if improperly performed, might possibly re-
sult in personal harm to the user, or damage to property.
SAFETY PRECAUTIONS ........................................En-1
FEATURES AND FUNCTIONS ...............................En-2
NAME OF PARTS ................................................... En-3
PREPARATION .......................................................En-5
OPERATION ............................................................En-6
TIMER OPERATION ............................................... En-8
SLEEP TIMER OPERATION ................................... En-9
ADJUSTING THE DIRECTION OF
AIR CIRCULATION ............................................... En-10
AIR OUTLET SELECTION .................................... En-11
10°C HEAT OPERATION ...................................... En-12
ECONOMY OPERATION ...................................... En-12
SWING OPERATION ............................................En-13
MANUAL AUTO OPERATION ............................... En-13
CLEANING AND CARE .........................................En-14
TROUBLESHOOTING .......................................... En-16
OPERATING TIPS ................................................. En-18
CONTENTS
OPERATING MANUAL
FLOOR TYPE
PART No. 9378532052
En-2
FEATURES AND FUNCTIONS
INVERTER
At the start of operation, large amount of power is used to
bring the room quickly to the desired temperature. Afterwards,
the unit automatically switches to a low power setting for eco-
nomic and comfortable operation.
AUTO CHANGEOVER
The operation mode (cooling, dry, heating) is switched auto-
matically to maintain the set temperature, and the temperature
is kept constant at all times.
10°C HEAT OPERATION
The room temperature can be maintained at 10°C so as to
prevent the room temperature from falling too far.
ECONOMY OPERATION
When economy operation mode is operated, the room temper-
ature will be little higher than the set-temp under cooling mode
and lower than set-temp under heating mode. Therefore, the
economy mode is able to save more energy than other normal
mode.
PROGRAM TIMER
The program timer allows you to integrate OFF timer and ON
timer operations in a single sequence. The sequence can
involve 1 transition from OFF timer to ON timer, or from ON
timer to OFF timer, within a 24 hour period.
SLEEP TIMER
When the SLEEP button is pressed during Heating mode, the
air conditioner’s thermostat setting is gradually lowered during
the period of operation; during cooling mode, the thermostat
setting is gradually raised during the period of operation. When
the set time is reached, the unit automatically turns off.
WIRELESS REMOTE CONTROLLER
The Wireless Remote Controller allows convenient control of
air conditioner operation.
SWING OPERATION
The Airflow Direction Louvers swings automatically up and
down so that the air speeds to every nook and corner of your
room.
REMOVABLE OPEN PANEL
The indoor unit’s Open Panel can be removed for easy clean-
ing and maintenance.
SUPER QUIET OPERATION
When the FAN button is used to select QUIET, the unit begins
super-quiet operation; the indoor unit’s air ow is reduced to
produce quieter operation.
APPLE-CATECHIN FILTER
The APPLE-CATECHIN FILTER uses static electricity to clean
ne particles and dust in the air such as tobacco smoke and
plant pollen that are too small to see.
ION DEODORIZATION FILTER
The filter deodorizes by powerfully decomposing absorbed
odors using the oxidizing and reducing effects of ions gener-
ated by the ultra- ne-particle ceramic.
WIRED REMOTE CONTROLLER (OPTION)
The optional wired
remote
controller can be used.
When you use remote controller, there are following different
points as compared with using wireless remote controller.
[The additional functions for wired ones]
Weekly timer
Temperature set back timer
And you can use both wired and wireless remote controller si-
multaneously.
(But function is limited)
When the restricted functions on the remote controller are
used, beeping sound will be heard, OPERATION, TIMER and
the 3rd lamp of the indoor unit will ash.
[The restricted functions for wireless ones]
SLEEP TIMER
TIMER
10°C HEAT


Product specificaties

Merk: Fuji Electric
Categorie: Airco
Model: AGF14UI

Heb je hulp nodig?

Als je hulp nodig hebt met Fuji Electric AGF14UI stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Fuji Electric

Handleiding Airco

Nieuwste handleidingen voor Airco