Fluke SV225 Handleiding


Lees hieronder de đź“– handleiding in het Nederlandse voor Fluke SV225 (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 29 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
®
Instruction Sheet
SV225
Stray Voltage Eliminator
IV
IV
IV
IV
CA
CA
CA
CAT
T
T
T
600
600
600
600
V
V
V
V
Introduction
The SV225 Stray Voltage Eliminator (hereafter referred to as
“the Adapter”) is a digital multimeter accessory that allows
measurements in circuits which may be subject to stray
voltages encountered from adjacent-energized wiring.
The Adapter provides an approximate 3,000 e load to the
measured circuit, desensitizing the meter to low energy,
spurious sources of interference. The Adapter is only used for
voltage measurements. When used with a compatible digital
multimeter, it can be determined whether the circuits under test
are energized or not.
Safety Information
XW Read First: Safety Information
To avoid possible electric shock or personal
injury:
• Read the operating instructions before use
and follow all safety instructions.
• Use caution when working with voltages
above 60 V dc or 30 V ac. Such voltages pose
a shock hazard.
• Before testing the desired circuit, ensure that
the multimeter and Adapter are functioning
properly by testing a known live circuit. A de-
energized circuit will be indicated on the
multimeter display as a reading near zero
volts.
• When using the Adapter to eliminate stray or
ghost voltage, the Adapter has a low input
impedance, nominally 3,000 Ω
Ω
Ω
ΩΩ. This low
impedance places a moderate load on the
circuit under test. Do not use the Adapter to
measure live voltages in circuits that could be
damaged by a 3 kΩ
Ω
Ω
ΩΩ load.
PN 2429231
March 2005 Rev.1, 11/05
© 2005 Fluke Corporation. All rights reserved. Printed in U.S.A.
All product names are trademarks of their respective companies.
• Do not apply more than the rated voltage, as
marked on the multimeter or in the Adapter
specifications (whichever is lower) between
the terminals, or between any terminal and
earth ground.
• Before each use, inspect test leads for
damage and check for continuity. Do not use
leads that are damaged or show high
resistance. Look for cracks or missing plastic
on the lead housing or cable insulation.
• Adhere to local and national safety codes.
• Individual protective equipment must be used
to prevent shock and injury.
• If the equipment is used in a manner not
specified by the manufacturer, the protection
provided by the equipment may be impaired.
• The Adapter is specified for CAT III
1000V/CAT IV 600V per EN61010.
• CAT III equipment is designed to protect
against transients in equipment in fixed-
equipment installations, such as distribution
panels, feeders and short branch circuits, and
lighting systems in large buildings.
• CAT IV equipment is designed to protect
against transients from the primary supply
level, such as an electricity meter or an
overhead or underground utility service.
Symbols
The following symbols appear on the Adapter or in this
instruction sheet.
T Product is protected by double insulation.
W Risk of Danger. Important information. See
Instruction Sheet.
X Hazardous voltage.
;
N10140 Conforms to relevant Australian standards.
P Conforms to relevant European Union directives.
Specifications
Voltages up to 1000 volts continuous can be safely applied to
the Adapter without damage.
Operation Temperature
-20 °C to +55 °C (-40 °F to 131 °F)
Altitude
2,000 Meters Operating
Humidity
90 % at 0 to 35 ° ° °C (32 F to 95 F), 70 % at 35 to 55 °C
(95 °F to 131 °F)
Nominal Resistance
3,000 Ω @ 25 °C (77 °F)
Instrument Compatibility
The Adapter is for use with any high-impedance digital
multimeter (≥ 1 M ) which accepts 4 mm safety-shrouded Ω
banana plugs and with any test leads using the same safety-
shrouded banana plugs. The Adapter is compatible with the
following Fluke digital multimeters and testers:
• Fluke 27
• 70 Series
• 80 Series
• Fluke-110 Series
• 170 Series
• 180 Series
Operation
To use the Adapter, do the following:
1. Plug the Adapter into the digital multimeter’s V/Ω
Ω
Ω
ΩΩ and
COMMON input jacks.
2. Plug the test leads into the Adapter input jacks observing
the proper polarity (red lead to red jack, black lead to black
jack). Make sure the leads and Adapter are fully
connected to the instrument.
3. Turn the multimeter’s function switch to the Volts AC
measurement function.
XW Warning
To avoid possible electric shock or personal
injury, before testing the desired circuit, ensure
that the multimeter and Adapter are functioning
properly by testing a known live circuit. A de-
energized circuit will be indicated on the
multimeter display as a reading near zero volts.
4. After determining the circuit under test is de-energized,
retest the known live circuit again to insure the multimeter
and Adapter are still working properly.
Note
Most digital multimeters never display a zero-volt
reading for a de-energized circuit. A small residual
reading may always be present.
The example in Figure 1 shows a reading of 13.2
millivolts AC which is very close to a zero-volt reading.
1 millivolt is equal to .001 volts or 1/1000th of a volt.
Figure 1. Residual Voltage Reading
Maintenance
Cleaning
W Caution
To avoid damaging the Adapter, do not use
abrasives or solvents for cleaning.
Periodically wipe the Adapter with a damp cloth and mild
detergent.
Contacting Fluke
To contact Fluke, call one of the following telephone numbers:
USA: 1-888-44-FLUKE (1-888-443-5853)
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31 402-675-200
Japan: +81-3-3434-0181
Singapore: +65-738-5655
Anywhere in the world: +1-425-446-5500
USA Service: 1-888-99-FLUKE (1-888-993-5853)
Or, visit Fluke's Web site at www.fluke.com.
To register your product, visit register.fluke.com
LIMITED WARRANTY AND LIMITATION OF LIABILITY
This Fluke product will be free from defects in material and
workmanship for one year from the date of purchase. This warranty
does not cover fuses, disposable batteries, or damage from accident,
neglect, misuse, alteration, contamination, or abnormal conditions of
operation or handling. Resellers are not authorized to extend any other
warranty on Fluke’s behalf. To obtain service during the warranty
period, contact your nearest Fluke authorized service center to obtain
return authorization information, then send the product to that Service
Center with a description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER
WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR
PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE
FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL
DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY.
Since some states or countries do not allow the exclusion or limitation
of an implied warranty or of incidental or consequential damages, this
limitation of liability may not apply to you.
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
U.S.A.
Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
11/99


Product specificaties

Merk: Fluke
Categorie: Niet gecategoriseerd
Model: SV225
Kleur van het product: Black, Red, Yellow
Certificering: CE
Maximale hoogte, in gebruik: 2000 m
Bedrijfstemperatuur (T-T): -20 - 55 °C
Spanningclassificatie: 1000 V
Ondersteunde meetcategorieën: CAT III, CAT IV
Interne weerstand: 3000 Ohm

Heb je hulp nodig?

Als je hulp nodig hebt met Fluke SV225 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Fluke

Fluke

Fluke ii500 Handleiding

7 Oktober 2024
Fluke

Fluke iSee TC01A Handleiding

9 September 2024
Fluke

Fluke TiX885 Handleiding

7 December 2023
Fluke

Fluke TiX875 Handleiding

7 December 2023
Fluke

Fluke TiX880 Handleiding

7 December 2023
Fluke

Fluke TiX870 Handleiding

7 December 2023
Fluke

Fluke EI-162BN Handleiding

9 Augustus 2023
Fluke

Fluke CNX C3003 Handleiding

8 Augustus 2023
Fluke

Fluke 80i-2010s Handleiding

8 Augustus 2023

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd