Fluke SureGrip 80PK-27 Handleiding

Fluke Niet gecategoriseerd SureGrip 80PK-27

Lees hieronder de 📖 handleiding in het Nederlandse voor Fluke SureGrip 80PK-27 (5 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 13 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/5
®
80PK-27
SureGripTM Industrial Surface
Temperature Probe
Instruction Sheet
XWWarning
To avoid electrical shock, do not use this probe
when voltages exceeding 24 V ac rms or 60 V dc
are present. The probe tip is electronically
connected to the output terminals.
XW Attention
Pour éviter les risques d’électrocution, ne pas
utiliser cette sonde quand la tension est
sepérieure à 24 V efficaces en courant alternatif
ou 60 V en courant continu. La pointe de la sonde
est reliée électriquement aux bornes de sorties.
XW Warnung
Um Elektroschock zu vermeiden, dürfen Sie den
Meßstift nicht in der Anwesenheit von
Spannungen über 24V Wechselstrom oder 60V
Gleichstrom verwenden. Die Spitze des Meßstifts
ist mit den Ausgangsanschlüssen elektrisch
verbunden.
XW Advertencia
Para evitar descargas eléctricas, no use esta
sonda cuando se apliquen voltajes que
sobrepasen 24 V ca rcm o 60 V cc. La punta de la
sonda está conectada eléctricamente a las
terminales de salida.
Introduction
The 80PK-27 SureGrip
TM Industrial Surface Temperature
Probe is designed for reliably measuring temperatures to 600
° °C (1112 F) on flat or slightly convex surfaces, while retaining
a long service life.
Specifications
Type: K (Chromel vs Alumel)
Measurement Range: -127 C °C to 600 °
(-196.6 °F to 1112 °F)
Junction Accuracy: -127 C °C to 0 °C ±4.4 °
(-196.6 °F to 32 °F ± 7.92 °F)
0 °C to 183 °C ±2.2 °C
(32 °F to 361 °F ±4.86 °F)
183 °C to 600 °C ±1.2 % of reading in °C
(361 °F to
1112 °F ± <1.2 % of reading
in °F)
Output: 25 ° ° °C (77 F) = 1.00 mV (Reference junction at 0 C)
Seebeck Coefficient: 25 °C (77 °F) = 40.50 µ °V/ C
November 2004
© 2004 Fluke Corporation. All Rights Reserved.
All product names are trademarks of their respective companies
Measurement Time (Time Constant): 1 time constant equals
330 ms; 5 time constants equal final reading. See “Application
Information” below.
Maximum Voltage Rating at Probe Tip: 24 V ac rms, or 60 V
dc
Probe Tip: Maximum Temperature: 600 °C
(1112 °F)
Material: 303 stainless steel
Sheath Material: 303 stainless steel
Cable Length: 40 inches (1 meter)
Cable Isulation: Material: PVC
Maximum Temperature: 105 °C (220 °F)
Minimum Temperature: -20 °F
Conductors: Type: K
Size: AWG #24 stranded (7 strands of #32)
Length: 1.2 meters nominal (4 ft)
Handle: Material: Hytrel
Maximum Temperature: 65.6 °C (150 °F)
Minimum Temperature: -40 °C (-40 °F)
Connector:
Type: yellow mini-thermocouple connector with 0.792
mm (0.312 in) pin spacing
Material: Hytrel
Maximum Temperature: 125 °C (275 °F)
Dimensions:
Diameter: 22.9 mm (0.9 in)
Length: 322.6 mm (12.75 in)
Measurement Considerations
Instrument Compatibility
The 80PK-27 is designed to be compatible with any
temperature measuring instrument that accepts Type K
thermocouples, has a miniature thermocouple connector, and
has cold reference junction compensation. Accuracy of the
temperature measuring instrument must be considered along
with the 80PK-27 accuracy specifications in order to determine
the overall accuracy of the combination.
Temperature Limitations
The probe tip has continuous temperature rating of 600 °C.
However the rest of the assembly is rated for a lower
temperature. See the specifications for further information.
Media Limitations
Media must be compatible with Chromel, Alumel, and 303
stainless steel.
Application Information
At high temperatures, a surface temperature probe removes a
small amount of heat from the measured surface. At 600 °C on
a polished metal surface, the temperature at a contact point
will be lowered, typically not more than 2 °C. A lowering of the
temperature at the contact point is less likely (and contact
response time is quicker) on clean, polished, thermally
conductive surfaces than on materials with low thermal
conductivity, such as plastic or rough, contaminated surfaces.
To obtain the best thermal contact and performance, the
stainless steel ring must make full and firm contact with the
measurement surface.
Operation
Use the 80PK-27 as follows:
1. Using the miniature thermocouple connector, connect the
80PK-27 to a compatible Type K temperature measuring
instrument.
2. Turn on the measuring instrument and select the
appropriate range and scale.
3. Read the temperature on the measuring instrument. When
no heat or cold is applied to the sensing ribbon, the
measuring instrument should display the ambient (room)
temperature. If the instrument does not readout properly,
refer to “Troubleshooting”.
Measuring Technique
To improve the accuracy of your temperature measurements:
When measuring higher than ambient temperatures,
adjust the connection between the probe and the surface
until you get the highest temperature reading.
When measuring lower than ambient temperatures, adjust
the connection between the probe and the surface until
you get the lowest temperature reading.
When measuring near ambient temperatures, make the
reading when the thermometer readout is most stable.
Troubleshooting
When no heat or cold applied to the probe, the measuring
instrument should display the ambient temperature. If the
measuring instrument does not do so, try the following:
1. Verify that the temperature measuring instrument is
designed for Type K thermocouples. It should have a
yellow input connector and/or be marked “K”.
2. Check for an open circuit indicator on the measuring
instrument. Some temperature measuring instruments
have a built-in circuit to indicate if the connected probe is
open. (All Fluke instruments have this feature.) Refer to
instrument's owner’s manual to see if this feature is
available.
If you suspect a broken connection, use an ohmmeter to
check probe continuity from pin to pin. If the ohmmeter
should read 10 ohms or less if there is continuity.
3. Short the two input pins of the measuring instrument with
a piece of wire. If the instrument is functioning it should
indicate the ambient temperature.


Product specificaties

Merk: Fluke
Categorie: Niet gecategoriseerd
Model: SureGrip 80PK-27

Heb je hulp nodig?

Als je hulp nodig hebt met Fluke SureGrip 80PK-27 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Fluke

Fluke

Fluke ii500 Handleiding

7 Oktober 2024
Fluke

Fluke iSee TC01A Handleiding

9 September 2024
Fluke

Fluke TiX885 Handleiding

7 December 2023
Fluke

Fluke TiX875 Handleiding

7 December 2023
Fluke

Fluke TiX880 Handleiding

7 December 2023
Fluke

Fluke TiX870 Handleiding

7 December 2023
Fluke

Fluke EI-162BN Handleiding

9 Augustus 2023
Fluke

Fluke CNX C3003 Handleiding

8 Augustus 2023
Fluke

Fluke 80i-2010s Handleiding

8 Augustus 2023

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd