ITP 120
Isolated Trigger Probe
Instruction Sheet
Introduction
The ITP 120 is an optically isolated trigger probe for
isolated trigger purposes with the Fluke 120 series
ScopeMeter test tool.
Specifications
Probe Characteristics
Maximum floating voltage to ground: 600V
Maximum input voltage: 600V (with 600V Mini
Testhook)
Maximum non-destructive input voltage times
frequency: 109
Input resistance: 10 MΩ ± 1%
Input capacitance: 15 pF ± 10%
Probe length: 1.2 m (48 inch)
Trigger Characteristics
Trigger level: TTL compatible (High ≥ 2V, Low ≤ 0.8V)
Minimum pulsewidth: 7 µs
Frequency range: DC to 50 kHz
Trigger slope selectable on the ScopeMeter test tool.
Battery Type: Alkaline 9 volt, NEDA, IEC6LR61
Battery Life: 60 hour operation
June 1996, Rev. 3, 4/10
© 1996, 1997, 2010 Fluke
Corporation.
All rights reserved.
Printed in The Netherlands.
All product names are trademarks of their respective companies
Environmental Specifications
Meet requirements of:
• MIL-T-28800E, Type III, Class 3
• EN 50081-1, Electromagnetic Compatibility
Generic Emission Standard: EN55022 and
EN60555-2
• EN 50082-1, Electromagnetic Compatibility
Generic Immunity Standard: IEC1000-4 -2, -3, -4,
-5
This product is in conformity with Electromagnetic
Compatibility Directive 2004/108/EC, and Low Voltage
Directive 2006/95/EC.
This conformity is indicated by the symbol , i.e.
“Conformité européenne”
Temperature:
Operating: 0 °C to +50 °C (32 °F to +122 °F)
Non-operating: -40 °C to +70 °C (-40 °F to +158 °F)
Safety
Meets requirements of:
• UL 3111
• IEC1010-2-031 CAT II 600V ( Double Insulation)
Unpacking
Check that the following items are included with the ITP
120:
• Trigger Probe
• Mini Testhook (with ground lead)
• 9V Battery (installed)
Using the ITP 120
Limited Warranty &
Limitation of Liability
This Fluke product will be free from defects in material
and workmanship for one year from the date of
purchase. This warranty does not cover fuses,
disposable batteries or damage from accident, neglect,
misuse or abnormal conditions of operation or handling.
Resellers are not authorized to extend any other
warranty on Fluke’s behalf. To obtain service during the
warranty period, send your defective product to the
nearest Fluke Authorized Service Center with a
description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO
OTHER WARRANTIES, SUCH AS FITNESS FOR A
PARTICULAR PURPOSE, ARE EXPRESSED OR
IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL,
INDIRECT, INCIDENTAL OR CONSEQUENTIAL
DAMAGES OR LOSSES, ARISING FROM ANY
CAUSE OR THEORY.
Since some states or countries do not allow the
exclusion or limitation of an implied warranty or of
incidental or consequential damages, this limitation of
liability may not apply to you.
Fluke Corporation Fluke Industrial B.V.
P.O. Box 9090 P.O. Box 90
Everett WA 98206-9090 7600 AB Almelo
USA. The Netherlands
Service Centers
To locate an authorized service center, visit us on the
World Wide Web:
http://www.fluke.com
or call Fluke using any of the phone numbers listed
below:
+1-888-993-5853 in USA and Canada
+31-40-2675200 in Europe
+1-425-446-5500 from other countries
Replacing the Battery
Connecting the ITP 120
Repairing the ITP 120
B
o 5(WT)
o 4(BN)
o 3(YE)
o 2(BK)
o 1(RD)
}A
METAL SHIELD IS
GROUND
C
D
3*
No trigger function:
A. Apply 1kHz } 0..+10V
B. Check for 1kHz } 0...+0.8V
Not OK: replace item 13.
C. Check 3 for 6ÎĽs pulses } -1.2...-2.5V
Not OK: replace item 1.
OK: check 3* for pulses } -2.5...-2.5V
OK: replace item 1.
Not OK: replace item 11.
Trigger slope error:
D. Connect ITP120 to test tool
Select +slope and check wire 1 for +1.2V
Select - slope and check wire 1 for -2.5V
OK: replace item 11. Not OK: replace item 1
ITEM ORDERING CODE DESCRIPTION
1 5322 324 00003 Optical Cable Assembly
2 5322 325 10162 Grommet
3 5322 401 11648 Cable Clamp
4 4822 290 80346 Battery Connect Cable
5 4822 138 10116 9V Alkaline Battery
6 5322 442 00162 Bottom Cover
7 5322 502 14063 Captive Screw M3x20
8 5322 454 13174 Top Text Plate
9 5322 442 00161 Top Cover
10 5322 410 10319 Slider
11 5322 216 04254 Printed Circuit Assembly
12 5322 401 11652 Cable Clamp
13 5322 210 10728 Probe Assembly
14 5322 401 11653 600V Mini Hook Clip
15 5322 454 13176 Warning Sticker
Alkaline 9 volt,
NEDA,
IEC6LR61
ITP 120


Product specificaties

Merk: Fluke
Categorie: Niet gecategoriseerd
Model: ITP120

Heb je hulp nodig?

Als je hulp nodig hebt met Fluke ITP120 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Fluke

Fluke

Fluke ii500 Handleiding

7 Oktober 2024
Fluke

Fluke iSee TC01A Handleiding

9 September 2024
Fluke

Fluke TiX885 Handleiding

7 December 2023
Fluke

Fluke TiX875 Handleiding

7 December 2023
Fluke

Fluke TiX880 Handleiding

7 December 2023
Fluke

Fluke TiX870 Handleiding

7 December 2023
Fluke

Fluke EI-162BN Handleiding

9 Augustus 2023
Fluke

Fluke CNX C3003 Handleiding

8 Augustus 2023
Fluke

Fluke 80i-2010s Handleiding

8 Augustus 2023

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd