Fluke FTP17XXPQ Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Fluke FTP17XXPQ (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 52 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
FTP17XXPQ
Fused Test Probe Set
3-Phase PQ, AC285, R/B
Instructions
Introduction
The FTP17XXPQ (the Product) is a set of four FTP-1 SureGrip Fused
Test Probes with adapters and AC285 alligator clips. These test probes
are for use with standard test leads that have 4 mm safety plugs. The
Product has a replaceable 1000 V, 11 A, 20 kA IR fuse for additional
measurement protection.
How to Contact Fluke
Fluke Corporation operates worldwide. For local contact information, go
to our website: www.uke.com
To register your product, view, print, or download the latest manual or
manual supplement, go to our website.
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
+1-425-446-5500
uke-info@uke.com
PN 4957684
January 2018 Rev. 1, 4/21
© 2018-2021 Fluke Corporation. All rights reserved.
Product specications are subject to change without notice.
Symbols
The table below is a list of symbols used on the Product and in this
document.
Symbol Description
WARNING - RISK OF DANGER. Consult user documentation.
WARNING. HAZARDOUS VOLTAGE. Risk of electric shock.
Consult user documentation.
Double Insulated
Fuse
Measurement Category II is applicable to test and measuring circuits
connected directly to utilization points (socket outlets and similar
points) of the low-voltage MAINS installation.
Measurement Category III is applicable to test and measuring circuits
connected to the distribution part of the building’s low-voltage MAINS
installation.
Measurement Category IV is applicable to test and measuring
circuits connected at the source of the building’s low-voltage MAINS
installation.
Conforms to European Union directives.
This product complies with the WEEE Directive marking
requirements. The a󰀩xed label indicates that you must not discard
this electrical/electronic product in domestic household waste.
Product Category: With reference to the equipment types in the
WEEE Directive Annex I, this product is classed as category 9
“Monitoring and Control Instrumentation” product. Do not dispose of
this product as unsorted municipal waste.
LIMITED WARRANTY AND LIMITATION OF LIABILITY
This Fluke product will be free from defects in material and workmanship for one
year from the date of purchase. This warranty does not cover fuses, disposable
batteries, or damage from accident, neglect, misuse, alteration, contamination,
or abnormal conditions of operation or handling. Resellers are not authorized to
extend any other warranty on Fluke’s behalf. To obtain service during the warranty
period, contact your nearest Fluke authorized service center to obtain return
authorization information, then send the product to that Service Center with a
description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH
AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED.
FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR
THEORY. Since some states or countries do not allow the exclusion or limitation
of an implied warranty or of incidental or consequential damages, this limitation of
liability may not apply to you.
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
U.S.A.
Fluke Europe B.V
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
11/99
Safety Information
A Warning identies conditions and procedures that are dangerous to
the user. A Caution identies conditions and procedures that can cause
dameage to the Product or the equipment under test.
 Warning
To prevent electrical shock, re, or personal injury:
Read all safety information before you use the Product.
Do not alter the Product and use only as specied, or the
protection supplied by the Product can be compromised.
Comply with local and national safety codes. Use personal
protective equipment (approved rubber gloves, face protection,
and ame-resistant clothes) to prevent shock and arc blast injury
where hazardous live conductors are exposed.
Do not exceed the Measurement Category (CAT) rating of the
lowest rated individual component of a Product, probe, or
accessory.
Measure a known voltage rst to make sure that the Product
operates correctly.
Hold the Product behind the tactile barrier when the 4 mm adapter
A is not attached.
Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.
Do not use the Product around explosive gas, vapor, or in damp or
wet environments.
Do not use the Product if it is altered or damaged.
Do not use in CAT III or CAT IV environments without the adapters
installed. The adapters decreases the exposed probe metal to
<4 mm. This decreases the possibility of arc ash from short
circuits.
Do not make connections on hazardous live conductors in damp
or wet environments.
Limit operation to the specied measurement category, voltage, or
amperage ratings.
Do not use a shrouded banana jack
accessory such as an alligator clip
with an unshrouded 4 mm banana
probe tip terminal in a hazardous
electrical installation. Due to the lack
of a shroud, the probe tip connector
does not provide suitable insulation
to accessible parts with this type of
assembly.
Unpack
The Product includes these items:
FTP-1 SureGrip Fused Test Probes (1 black for connecting to neutral
voltage, 3 red for connecting to phase voltages)
AC285 Alligator Clips (1 black, 3 red)
Adapters that securely attach the Fluke AC285 alligator clips to the
Fused Test Probes (4)
FTP17XXPQ Instructions
At delivery, make sure that the shipment is complete and all items are
undamaged. Contact your supplier if you see any damage.
Operation
To use:
1. Thread the adapter onto the probe . A B
2. Push on the alligator clip AC285 C securely for a rm connection for
CAT III/CAT IV measurements.
Maintenance
Clean the Product with a damp cloth and mild detergent. Do not immerse
in liquid.
Fuse Information
To replace fuse:
1. .Unscrew the handle at the nger guard D
2. Replace the fuse.
Caution
For safety, replace with Fluke part number 803293 only.
3. Screw handle into place.
When the fuse is blown, a 1 M parallel resistor allows the meter to take Ω
a measurement and indicate if live voltage is present. This measurement
helps to prevent a possible misreading of no voltage present. The input
impedance of the meter has signicant e󰀨ect on the reading error. See
table below.
Voltage Reading with Blown Fuse
Actual
MainsVoltage
Meter Input
Impedance[1]
Meter Reading (V)
with Blown Fuse Error (%)
480 V 417.9 12.910 MΩ
480 V 384.4 19.94 MΩ
480 V 226.3 52.81 MΩ
480 V 1.3 99.73 kΩ
[1] Fluke Power Quality Analyzers typically have input impedances >1 M Ω.
Specications
Input ............................................... 10 A maximum
Measurement protection .............. 1000 V, 11 A, 20 kA IR
Environmental
Operating temperature -20 C to +50 C (-5 F to +120 F) ............... ° ° ° °
Maximum altitude 3000 m .......................
Safety ............................................. IEC 61010-031, Pollultion Degree 2
CAT II 1000 V without adapters installed
CAT III 1000 V, CAT IV 600 V with adapters
installed
1
2
3 4


Product specificaties

Merk: Fluke
Categorie: Niet gecategoriseerd
Model: FTP17XXPQ

Heb je hulp nodig?

Als je hulp nodig hebt met Fluke FTP17XXPQ stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Fluke

Fluke

Fluke ii500 Handleiding

7 Oktober 2024
Fluke

Fluke iSee TC01A Handleiding

9 September 2024
Fluke

Fluke TiX885 Handleiding

7 December 2023
Fluke

Fluke TiX875 Handleiding

7 December 2023
Fluke

Fluke TiX880 Handleiding

7 December 2023
Fluke

Fluke TiX870 Handleiding

7 December 2023
Fluke

Fluke EI-162BN Handleiding

9 Augustus 2023
Fluke

Fluke CNX C3003 Handleiding

8 Augustus 2023
Fluke

Fluke 80i-2010s Handleiding

8 Augustus 2023

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd