Fluke FEV100 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Fluke FEV100 (14 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 201 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/14
FEV100
Electrical Vehicle Charging
Station Test Adapter
Users Manual
PN 5278136, April 2021
© 2021 Fluke Corporation. All rights reserved.
Specications are subject to change without notice.
All product names are trademarks of their respective companies.
1
Symbols
Symbol Description
WWARNING. RISK OF DANGER.
XWARNING. HAZARDOUS VOLTAGE. Risk of electric shock.
Consult user documentation.
TDouble Insulated.
Measurement Category II is applicable to test and measuring
circuits connected directly to utilization points (socket outlets
and similar points) of the low-voltage MAINS installation.
JEarth.
PE Protective Earth.
CP Control Pilot.
Vehicles not requiring ventilation for indoor charging areas.
Vehicles requiring ventilation for indoor charging areas.
This product complies with the WEEE Directive marking
requirements. The a󰀩xed label indicates that you must not
discard this electrical/electronic product in domestic household
waste. Product Category: With reference to the equipment
types in the WEEE Directive Annex I, this product is classed as
category 9 "Monitoring and Control Instrumentation" product.
Do not dispose of this product as unsorted municipal waste.
Table 1. Symbols
Introduction
The FEV100 (the Product) tests the function and safety of AC charging
stations Level 2 (208 V AC or 240 V AC) and Level 1 (120 V AC). With this
adapter, charging stations are tested in accordance with SAE J1772.
The adapter imitates a car and opens up a charging cycle (activate voltage/
current output). Use additional test and measurement equipment, such as
but not limited to: Multimeters, Clamps, Insulation testers or Multifunction
Testers, to test a charging station. In addition, the adapter has a built in quick
safety test that does not require separate equipment.
Contact Fluke
Fluke Corporation operates worldwide. For local contact information, go to
our website: www.uke.com
To register your product, view, print, or download the latest manual or manual
supplement, go to our website.
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
+1-425-446-5500
uke-info@uke.com
2
Safety Information
A Warning identies conditions and procedures that are dangerous to the
user. A Caution identies conditions and procedures that can cause damage
to the Product or the equipment under test.
WX Warning
To prevent the possibility of electric shock or personal injury:
Read all safety information before you use the Product.
Do not alter the Product and use only as specied, or the
protection supplied by the Product can be compromised.
Carefully read all instructions.
Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.
Before each use, examine the Product. Look for cracks or missing
pieces of the Product and cable assembly insulation. Also look for
loose or weakened components. Carefully examine the insulation
around the cable assembly connector.
Only connect the Product to the charging stations as indicated in
the Specication section.
Use the Product within the operating range only. The operating
range is specied in the Specication section.
Do not touch any part of charging station during the GFCI test.
The GFCI test may place hazardous voltage onto conductive parts
of the charging station during the test if the charging station is
not properly grounded.
Do not use the Product around explosive gas, vapor, or in damp
or wet environments.
Do not apply more than the rated voltage, between the terminals
or between each terminal and earth ground.
Use the correct terminals, function, and range for measurements.
Do not use the Product if it operates incorrectly.
Do not operate the Product with covers removed or the case
open. Hazardous voltage exposure is possible.
Use only specied replacement parts.
Do not use the Product if it is altered or damaged.
Have an approved technician repair the Product.


Product specificaties

Merk: Fluke
Categorie: Niet gecategoriseerd
Model: FEV100

Heb je hulp nodig?

Als je hulp nodig hebt met Fluke FEV100 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Fluke

Fluke

Fluke ii500 Handleiding

7 Oktober 2024
Fluke

Fluke iSee TC01A Handleiding

9 September 2024
Fluke

Fluke TiX885 Handleiding

7 December 2023
Fluke

Fluke TiX875 Handleiding

7 December 2023
Fluke

Fluke TiX880 Handleiding

7 December 2023
Fluke

Fluke TiX870 Handleiding

7 December 2023
Fluke

Fluke EI-162BN Handleiding

9 Augustus 2023
Fluke

Fluke CNX C3003 Handleiding

8 Augustus 2023
Fluke

Fluke 80i-2010s Handleiding

8 Augustus 2023

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd