Fluke 725 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Fluke 725 (80 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 24 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/80
®
724/725/726
Calibrators
Calibration Manual
PN 667581
September 1999 Rev. 3, 4/14
©1999-2014 Fluke Corporation. All rights reserved. Printed in USA
All product names are trademarks of their respective companies.
LIMITED WARRANTY AND LIMITATION OF LIABILITY
Each Fluke product is warranted to be free from defects in material and workmanship under normal use and
service. The warranty period is three years and begins on the date of shipment. Parts, product repairs, and
services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of
a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any product which, in
Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal
conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with
its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke
does not warrant that software will be error free or operate without interruption.
Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers
only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is
available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the
applicable international price. Fluke reserves the right to invoice Buyer for importation costs of
repair/replacement parts when product purchased in one country is submitted for repair in another country.
Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair,
or replacement of a defective product which is returned to a Fluke authorized service center within the
warranty period.
To obtain warranty service, contact your nearest Fluke authorized service center to obtain return
authorization information, then send the product to that service center, with a description of the difficulty,
postage and insurance prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Following
warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke
determines that failure was caused by neglect, misuse, contamination, alteration, accident, or abnormal
condition of operation or handling, including overvoltage failures caused by use outside the product’s
specified rating, or normal wear and tear of mechanical components, Fluke will provide an estimate of repair
costs and obtain authorization before commencing the work. Following repair, the product will be returned to
the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges
(FOB Shipping Point).
THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE
FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES,
INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or
limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not
apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other
decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other
provision.
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
U.S.A.
Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
11/99
i
Table of Contents
Title Page
Introduction ........................................................................................................ 1
Contacting Fluke ................................................................................................ 1
Read First – Safety Information ......................................................................... 2
International Symbols ........................................................................................ 3
Specifications ..................................................................................................... 4
DC Voltage Measurement (724 and 725) ...................................................... 4
DC Voltage Measurement and Source (726) ................................................. 4
DC Voltage Source (724 and 725) ................................................................ 4
DC mA Measurement and Source (724 and 725) (Measurement
only for 724) .................................................................................................. 4
DC mA Measurement and Source (726) ....................................................... 5
Ohms Measurement (724 and 725) ............................................................... 5
Ohms Measurement (726) ............................................................................. 5
Ohms Source (724 and 725) .......................................................................... 5
Ohms Source (726) ........................................................................................ 6
Frequency Measurement (725) ...................................................................... 6
Frequency Measurement (726) ...................................................................... 6
Frequency Source (725) ................................................................................ 6
Frequency Source (726) ................................................................................ 7
Millivolt Measurement and Source (724 and 725) ........................................ 7
Temperature, Thermocouples (724 and 725)................................................. 7
Temperature, Thermocouples (726) .............................................................. 8
Temperature, RTD Ranges, and Accuracies (724 and 725) .......................... 9
RTD Accuracy (Read and Source) (ITS-90) (726)........................................ 10
Loop Power Supply ....................................................................................... 11
Pressure Measurement (725 and 726) ........................................................... 11
Pulse Read and Pulse Source (726) ............................................................... 11
Pressure Units Availability (725) .................................................................. 11
General Specifications ................................................................................... 12
Cleaning the Calibrator ...................................................................................... 12
Replacing the Batteries ...................................................................................... 13
Fuses .................................................................................................................. 14
Remote Control Interface (725 and 726) ........................................................... 15
Serial Command List (726) ................................................................................ 18
Performance Tests .............................................................................................. 25
Preparing for the Performance Tests ............................................................. 25
Upper Display Voltage Measurement Tests .................................................. 26
Lower Display mV/TC Measurement Tests .................................................. 27
Lower Display Voltage Measurement Tests .................................................. 28
Upper Display mA Measurement Tests ......................................................... 29
Lower Display mA Measurement Tests (725 and 726) ................................. 30


Product specificaties

Merk: Fluke
Categorie: Niet gecategoriseerd
Model: 725
Kleur van het product: Black, Yellow
Breedte: 130 mm
Diepte: 61 mm
Hoogte: 236 mm
Pulse function: Ja
Meetkabels: Ja
Gemeten parameters: Current, Frequency, Pressure, RTD, Resistance, Temperature, Thermocouple, Voltage
Inclusief clips: Ja
Automatische gradiëntfunctie: Ja
Automatische stapfunctie: Ja
DC-spanningsmeetnauwkeurigheid: 0.025 procent
DC-stroommeetnauwkeurigheid: 0.02 procent
Weerstandsmeetnauwkeurigheid: 1 procent
Frequentiemeetnauwkeurigheid: 0.05 procent
Drukmeetnauwkeurigheid: 0.025 procent
DC-spanningsbronnauwkeurigheid: 0.025 procent
DC-stroombronnauwkeurigheid: 0.02 procent
Weerstandsbronnauwkeurigheid: 1 procent
Frequentiebronnauwkeurigheid: 0.25 procent
Pulsduur: 10 ms

Heb je hulp nodig?

Als je hulp nodig hebt met Fluke 725 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Fluke

Fluke

Fluke ii500 Handleiding

7 Oktober 2024
Fluke

Fluke iSee TC01A Handleiding

9 September 2024
Fluke

Fluke TiX885 Handleiding

7 December 2023
Fluke

Fluke TiX875 Handleiding

7 December 2023
Fluke

Fluke TiX880 Handleiding

7 December 2023
Fluke

Fluke TiX870 Handleiding

7 December 2023
Fluke

Fluke EI-162BN Handleiding

9 Augustus 2023
Fluke

Fluke CNX C3003 Handleiding

8 Augustus 2023
Fluke

Fluke 80i-2010s Handleiding

8 Augustus 2023

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd