Introduction
The Fluke Calibration 7102/7103 Micro-Bath (The Product) is a portable and bench-top
temperature calibrator that calibrates thermocouple and RTD temperature probes. For complete
Product use instructions, download the 7102 User’s Guide or the 7103 User’s Guide from
www.flukecal.com.
Note
The Product CD no longer ships with these Products.
Contact Fluke Calibration
Fluke Corporation operates worldwide. For local contact information, go to our website:
www.flukecal.com
To register your product, view, print, or download the latest User’s Guide or manual supplement, go
to our website.
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
+1-425-446-5500
info@flukecal.com
7102/7103
Micro-Bath
Safety Information
1-year limited warranty. See the User’s Guide for the full warranty.
PN 5311971
August 2021
© 2021 Fluke Corporation. All rights reserved. Specifications are subject to change without notice.
All product names are trademarks of their respective companies.
7102/7103
Safety Information
2
Safety Information
More specific safety information is listed in the User’s Guide where applicable.
A Warning identifies hazardous conditions and procedures that are dangerous to the user.
XW Warning
To prevent possible electrical shock, fire, or personal injury:
• Read all safety information before you use the Product.
• Carefully read all instructions.
• Use this Product indoors only.
• Do not use the Product if it operates incorrectly.
• Follow local regulations regarding use with toxic, flammable, corrosive, or
otherwise hazardous fluids. Incorrect product installation, abuse, or damage can
lead to operator exposure to these fluids. Limit hazardous-fluid exposure to
permitted levels in case of leakage or rupture.
• Do not operate the Product in an excessively wet, oily, dusty, or dirty environment.
• Do not use the Product if it is altered or damaged.
• Disable the Product if it is damaged.
• Replace the mains power cord if the insulation is damaged or if the insulation
shows signs of wear.
• Make sure that the power cord is positioned in such a way as it cannot contact hot
surfaces or temperature probes. Always inspect power cord before use for any
damage to the insulation due to contact with hot surfaces, cuts or abrasions.
• Do not alter the Product and use only as specified, or the protection supplied by
the Product can be compromised.
• Do not use the Product around explosive gas, vapor, or in damp, dusty, or wet
environments.
• Do not use the Product above its rated frequency.
• Connect an approved three-conductor mains power cord to a grounded power
outlet.
• Do not put the Product where access to the mains power cord is blocked.
• Make sure that the space around the Product meets minimum requirements. Leave
at least 15 cm (6 inches) of clearance around the Product.
• Do not use an extension cord or adapter plug.
• Do not keep the Product in operation and unattended at high temperatures.
• Turn the Product off and remove the mains power cord. Stop for two minutes to let
the power assemblies discharge before you open the fuse door.
• Replace a blown fuse with exact replacement only for continued protection
against arc flash.
• Turn off the Product and remove the mains power cord. Stop for 2 minutes to let
the internal circuits discharge before you open the fuse door or remove Product
covers.
• Have an approved technician repair the Product.
Micro-Bath
Safety Information
3
• Do not install an access cover without holes onto a bath that is energized.
Dangerous pressures may result from fluid vaporizing.
• Do not use the Product for any application other than calibration work. The
Product is for temperature calibration only. Any other use of the unit may cause
unknown hazards to the user.
• To move the Product, lift the Product by the handle provided. Do not move the
Product until the display reads <25 °C (77 °F) and the Product has been drained or
the transport lid installed.
• Always ensure the Product is cool before you close it for storage.
• Do not touch the well access surface of the Product.
• Do not mix water and oil when exceeding temperatures of 90 °C (194 °F). The
temperature of the well access is the same as the actual temperature shown on
the display. For example, if the Product is set at 125 °C (257 °F) and the display
reads 125 °C, the well is at 125 °C (257 °F).
• Do not operate near flammable materials. Extreme temperatures could ignite the
flammable material.
• The top sheet metal of the Product may exhibit extreme temperatures for areas
close to the well access.
• Do not turn off the unit at temperatures >100 °C (212 °F). This could create a
hazardous situation. Select a set-point <100 °C (212 °F) and allow the Product to
cool before you turn it off.
• Do not remove the fluid at high temperatures. The fluid will be the same
temperature as the display temperature.
• Use of this Product at high temperatures for extended time periods requires
caution.
• Always operate this Product at room temperatures listed in Environmental
Conditions in the User’s Guide.
• Overhead clearance is required. Do not place the Product under a cabinet or other
structure.
• Use a ground fault interrupt device.
• Fluids may expand at different rates. Allow for fluid expansion inside the well by
Keeping the fluid level at least 1.9 cm (0.75 inches) below the top of the well at all
times.
Product specificaties
Merk: | Fluke |
Categorie: | Temperatuurregelaar |
Model: | 7102 |
Heb je hulp nodig?
Als je hulp nodig hebt met Fluke 7102 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Temperatuurregelaar Fluke
8 Juli 2024
8 Augustus 2023
8 Augustus 2023
26 Juli 2023
4 Mei 2023
3 Mei 2023
21 April 2023
18 April 2023
16 April 2023
31 Maart 2023
Handleiding Temperatuurregelaar
- Temperatuurregelaar Panasonic
- Temperatuurregelaar AEG
- Temperatuurregelaar Honeywell
- Temperatuurregelaar ACV
- Temperatuurregelaar Astralpool
- Temperatuurregelaar Berker
- Temperatuurregelaar Bulex
- Temperatuurregelaar Davis
- Temperatuurregelaar Dimplex
- Temperatuurregelaar Hager
- Temperatuurregelaar Kathrein
- Temperatuurregelaar Techno Line
- Temperatuurregelaar Technoline
- Temperatuurregelaar Ventus
- Temperatuurregelaar Voltcraft
- Temperatuurregelaar Wachendorff
- Temperatuurregelaar Ygnis
- Temperatuurregelaar Jung
- Temperatuurregelaar Opticlimate
- Temperatuurregelaar Cocraft
- Temperatuurregelaar IFM
- Temperatuurregelaar Inkbird
- Temperatuurregelaar Carel
- Temperatuurregelaar Ziehl
- Temperatuurregelaar SRS
- Temperatuurregelaar Emko
- Temperatuurregelaar Jumo
Nieuwste handleidingen voor Temperatuurregelaar
5 December 2024
5 December 2024
2 December 2024
30 November 2024
30 November 2024
30 November 2024
18 November 2024
18 November 2024
18 November 2024
18 November 2024