Fluke 10A Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Fluke 10A (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 240 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
P
P
P
P
T
W
W
W
W
15
10.5 32
102
Tactile
Barrier
23.5
18.5
12.8
LIMITED WARRANTY AND LIMITATION OF LIABILITY
This Fluke product will be free from defects in material and
workmanship for one year from the date of purchase. This
warranty does not cover fuses, disposable batteries, or
damage from accident, neglect, misuse, alteration,
contamination, or abnormal conditions of operation or handling.
Resellers are not authorized to extend any other warranty on
Fluke’s behalf. To obtain service during the warranty period,
contact your nearest Fluke authorized service center to obtain
return authorization information, then send the product to that
Service Center with a description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER
WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR
PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT
LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM
ANY CAUSE OR THEORY. Since some states or countries do
not allow the exclusion or limitation of an implied warranty or of
incidental or consequential damages, this limitation of liability
may not apply to you.
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
U.S.A.
Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
11/99
®
1A/10A
Current Clamp Set
Instruction Sheet
Introduction
The 1A/10A Current Clamp Sets (the Clamp) have been
designed for applications with Fluke 1735 and 1740 series
products for accurate non-intrusive measurement of ac
currents. Using latest technologies (integrated memory for
calibration data) provides current ranges from 0.025 A up to
10 A in a frequency range of 40 Hz to 5 kHz.
Contacting Fluke
To contact Fluke, call one of the following telephone numbers:
USA: 1-888-44-FLUKE (1-888-443-5853)
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31 402-675-200
Japan: +81-3-3434-0181
Singapore: +65-738-5655
Anywhere in the world: +1-425-446-5500
USA Service: 1-888-99-FLUKE (1-888-993-5853)
Or, visit Fluke's Web site at www.fluke.com.
To register your product, visit http://register.fluke.com
Safety Instructions
Please read this section carefully. It will familiarize you with the
most important safety instructions for handling the Probe. In
this instruction sheet, a Warning identifies conditions and
actions that pose hazard(s) to the user. A Caution identifies
conditions and actions that may damage the calibrator or the
test instruments.
WX Warning
The Clamp may only be used and handled by
qualified personnel. To avoid personal injury,
follow these precautions:
• To avoid electric shock, use caution during
installation; high voltages and currents may
be present in circuit under test.
• Do not use the Clamp if damaged. Always
connect to display device before it is installed
around the conductor.
• Use the Clamp only as specified in the
operating instructions; otherwise the safety
features may not protect you.
• Adhere to local and national safety codes.
Individual protective equipment must be used
to prevent the shock and arc blast injury
where hazardous live conductors are
exposed.
• Before each use, inspect the Clamp. Look for
cracks or missing portions of the housing or
output cable insulation. Also look for loose or
weakened components.
PN 3373012
November 2008
©2008 Fluke Corporation, All rights reserved. Printed in The Netherlands.
Specifications are subject to change without notice. All product names are
trademarks of their respective companies.
• Use caution when working with voltages
above 60 V dc, 30 V ac rms or 42 V ac peak.
Such voltages pose a shock hazard.
• This Clamp is considered to be used in 600
CAT III environments. CAT III equipment is
designed to be used in distribution panels,
feeders and short branch circuit, and the
lighting system in large buildings.
• Do not use the Clamp in damp or wet
environments or in locations that hazardous
gases exist.
• Do not hold the Current Clamp anywhere
beyond the tactile barrier.
• De-energize circuit during installation and
removal of Probe.
Operating Instructions
1. Connect the Clamp to the current input jack of the
product. Verify that the product has recognized that a
current Clamp is connected.
2. In case of uninsulated conductors, de-energize the
circuit before placing the Clamp. Re-energize the
circuit.
3. Observe and take measurements as required.
Positive output indicates that the current flow is in the
direction shown by the arrow on the Clamp.
4. In case of uninsulated conductors, de-energize before
removal of the Clamp.
Cleaning
Clean the Probe periodically by wiping it with a damp cloth and
detergent. Do not use abrasive cleaners or solvents. Do not
immerse the Probe in liquids.
Symbols
~ Do not dispose of this product as unsorted municipal waste.
Go to Fluke’s website for recycling information.
W Risk of Danger. Important Information. See manual.
X Hazardous Voltage. Risk of electric shock.
T Double insulation.
- Do not apply around or remove from HAZARDOUS LIVE
conductors.
) Conforms to relevant Canadian Standards Association
directives.
P Conforms to relevant European Union directives.
Electrical Characteristics
Nominal current In: 1 / 10 A ac rms
Overload: up to 13 A rms.
Max. Non-destructive current: 100 A ac rms
Conductor position influence: <0.5 % of range at 50/60 Hz
Error due to adjacent conductor: ≤15 mA / A at 50 Hz
Phase shift at 2 kHz at 10 A: < ±1 degree
Frequency range: 40 Hz to 5 kHz (-3 dB)
Temperature coefficient: 0.015 % of range / °C
Working voltage (see section safety): 600 V ac rms or dc
Order reference:
3-phase 3024413: I1A/10A CLAMP PQ3
3-phase+N 3024424: I1A/10A CLAMP PQ4
Specifications
General Specifications
Maximum Conductor Size: 15 mm (0.59 in) diameter bus bar
15 x 17 mm (0.59 x 0.66 in)
Cable length: 2 m (6.56 ft)
Length of measuring head: 122 cm (4 ft)
Operating temperature range: -10 °C to +55 °C
(14 °F to 131 °F)
Storage temperature range: -20 °C to +70 °C
(-4 °F to 158 °F)
Operating humidity
(non-condensing): 15 % to 85 % rh
Weight: PQ4 730 g (1.6 lb); PQ3 560 g (1.25 lb)
Reference Conditions
Environment temperature range: +18 °C to +26 °C
(64.4 °F to 78.8 °F)
Humidity: 20 to 75 % rh
Altitude: max. 2000 m (1.24 mi)
Current: sinusoidal waveform, 48 Hz to 65 Hz, distortion
factor: <1 %, no dc component
Load impedance for voltage output: ≥1 MΩ, <100 pF
Safety Standards
IEC/EN61010-1: 2001
IEC/EN61010-2-032:2002
IEC/EN61010-031:2002
Safety Specifications
Category Rating: 600 V CAT III, pollution degree 2
EMC Standards: IEC/EN 61326-1:2006
Measurement Considerations
Observe the following guidelines when making measurements:
• Center the conductor inside the Clamp jaw.
• Make sure the Clamp is perpendicular to the conductor.
• For optimal reading, make sure the conductor is positioned
between the alignment marks on the jaws of the Clamp.
• Avoid taking measurements close to other current-carrying
conductors.
Accuracy (at 50 Hz)
Primary
current
0.025 A to
0.5 A 0.5 A to 2.5 A 2.5 A to 5 A 5 A to 10 A
Operating
error in %
of reading
± ± ± ±2.5 % 1.5 % 0.5 % 0.5 %
Phase
shift Not specified <2 ° <0.5 ° <1 °


Product specificaties

Merk: Fluke
Categorie: Niet gecategoriseerd
Model: 10A

Heb je hulp nodig?

Als je hulp nodig hebt met Fluke 10A stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Fluke

Fluke

Fluke ii500 Handleiding

7 Oktober 2024
Fluke

Fluke iSee TC01A Handleiding

9 September 2024
Fluke

Fluke TiX885 Handleiding

7 December 2023
Fluke

Fluke TiX875 Handleiding

7 December 2023
Fluke

Fluke TiX880 Handleiding

7 December 2023
Fluke

Fluke TiX870 Handleiding

7 December 2023
Fluke

Fluke EI-162BN Handleiding

9 Augustus 2023
Fluke

Fluke CNX C3003 Handleiding

8 Augustus 2023
Fluke

Fluke 80i-2010s Handleiding

8 Augustus 2023

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd