Festo VOFX-LT-M32C-MY-G18-SG18-3AA1 Handleiding

Festo Niet gecategoriseerd VOFX-LT-M32C-MY-G18-SG18-3AA1

Lees hieronder de 📖 handleiding in het Nederlandse voor Festo VOFX-LT-M32C-MY-G18-SG18-3AA1 (1 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 16 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/1
VOFX- -M32C-LT …-3AA1/-1A1-EX2- -1-EX4-M N/
Pilot valve
†‡
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com
Installation- and service instruction
8195271
2023-05
[8195273]
VOFX- -M32C-LT MY-G18-SG18-3AA1/-1A1-EX2-N/-1-EX4-M English ............
To assure the function and for your own safety please read the following
operating instructions carefully, before installing the product.
1 In General
Please notice that not following these instructions or any kind of
inappropriate engagement lead to the end of any kind of warranty and
liability from our side. Application and operation of the device must ensue in
accordance to general terms of technology.
Please undertake any means to avoid unintended actuation and
inappropriate use.
Always take into consideration that pressurised fittings, tubes and systems
are not to be opened.
Observe all national and international regulation of relevance.
Warnings
2 Installation
When taking the product out of the packaging take care that no dirt or other
particles are coming into the product.
Only use appropriate fittings that do not cause or lead to any dirt in the
system. Only use clean fittings and tubing.
Observe the manual of the actuator.
Install the product in a way that regular cleaning is possible.
Do not over-bend hoses or cables. Close unused ports.
Make sure that the exhaust ports are kept open, protect the exhaust ports
against condensate, dirt, insects etc.
Avoid water entering the exhaust port.
The mounting torque of the banjo-screw should be 7 Nm -0/+1 Nm.
3 Operation
Only use cleaned and lubricated or cleaned and unlubricated compressed air
quality level 7-4-4 for particles water oil following ISO 8573-1:2010. – –
The temperature of the compressed air and the environment must be
between °C and +50 °C. The operating pressure range of the valve is -0,9 –10
to 8 bar.
Using the valve below 0°C make sure to use dried air.
Further operation relevant information should be taken from the technical
datasheet.
Over-pressurising might lead to function failures.
Over-voltage might lead to burn out of the coil.
4 Service
The product is usually maintenance-free.
Check the function of the products regularly, minimum every 6 month or after
5 million switches.
5 Malfunctioning
Check the electric as well as pneumatic connections, operating pressure and
voltage.
If the problems are not solved by these, make sure before dismantling, that
there is no pressure applied to the ports and no electricity applied to the coil.
Dismantle the product.
Address authorised and educated personnel.
6 Technical characteristics of the coil
VOFX-LT-M32C- …
-3AA1
-1A1-EX2-N
-1-EX4-M
Coil characteristics
[V]
230 AC
24 DC
24 DC
[W]
–
2,1
2,6
Permissible voltage
fluctuations
[%]
± 10
± 10
± 10
Electrical connection
EN 175301-
803, type A
EN 175301-803,
type A
Encapsulated
Cable
connector
Port configuration:
• Port 1: Pressure supply port
• Port 2: Working port
(connect with actuator)
• Port 3: Exhaust port


Product specificaties

Merk: Festo
Categorie: Niet gecategoriseerd
Model: VOFX-LT-M32C-MY-G18-SG18-3AA1

Heb je hulp nodig?

Als je hulp nodig hebt met Festo VOFX-LT-M32C-MY-G18-SG18-3AA1 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Festo

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd