Pressure sensor SPAN
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com
Operating instructions 8035566
2017-11a
[8035568]
Translation of the original instructions
Pressure sensor SPAN English. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
For all available product documentation Γ¨ www.festo.com/pk
1 Product description
The operating instructions describe the entire function range. The function range is
limited, depending on the product variant.
Note
You can find detailed specifications for the product, the device description file
(IODD) with a description of the IO-Link parameters and the declaration of conξ˜‚
formity at: Γ¨ www.festo.com/sp.
1.1 Overview
1
2
3
456
1Display
2Electrical connection
3Pneumatic connection
4B-key
5Edit button
6A-key
Fig. 1 Representation of other variants can deviate from this
1.2 Characteristics
Characteristic Value Description
Type SPAN Pressure sensor
Pressure
measuring range
-B2, -B11, -P025, -P05, -P1, -P2,
-P6, -P10, -P12, -P16, -V025,
-V05, -V1
Γ¨ Technical data
Supply port R Relative pressure
Pneumatic port -G18, -R18, N18, -M5,
-Q4,
Thread Gx x x, R , NPT , M5
Push-in connector 4 mm
Thread type
M
F
None
Male thread
Female thread
Electrical
output 1
-PNLK
-PN
Switching output PNP / NPN / IO-Link
PNP / NPN
Electrical
output 2
-PNVBA
-PN
PNP / NPN / 0…10 V / 1…5 V / 4…20 mA
PNP / NPN
Electrical
connection
-L1 Plug connector, design L1
Certificate
+T
Without
With inspection report
Fig. 2
2 Safety
Intended use
The pressure sensor SPAN is intended for monitoring pressure of compressed air
and inert gases in the piping.
General safety information
ξ˜ƒ Only use the product in its original status, without any unauthorised modifications.
ξ˜ƒ Only use the product if it is in an excellent technical status.
ξ˜ƒ The product is intended for use in industrial environments. Measures may need
to be implemented in residential areas for radio interference suppression.
ξ˜ƒ Take into consideration the ambient conditions at the location of use.
ξ˜ƒ Operate the product only with compressed air of the specified air quality class
(Γ¨ Technical data).
ξ˜ƒ Observe the specifications on the rating plate.
ξ˜ƒ Comply with all applicable national and international regulations.
Disposal
ξ˜ƒ Observe the local specifications for environmentally friendly disposal.
Range of applications and certifications
In connection with the UL marking on the product, the information of this section is
also applicable for compliance with the certification conditions of Underwriters
Laboratories Inc. (UL) for the U.S.A. and Canada.
UL approval information
Product category code QUYX (USA)
QUYX7 (Canada)
File number E322346
Considered standards UL 61010ξ˜‚1
C22.2 No. 61010ξ˜‚1
UL mark
Fig. 3
Unit shall be supplied by a power source which complies with the requirements of
a limited-energy circuit in accordance with IEC/EN/UL/CSA 61010-1 or a Limited
Power Source (LPS) in accordance with IEC/EN/UL/CSA 60950-1 or IEC/EN/UL/
CSA 62368-1 or a Class 2 circuit in accordance with NEC or CEC.
3 Function and application
The sensor converts pneumatic pressure values (relative pressure) into electrical
signals, which can be used for control or regulating functions. Measurements are
carried out using a piezoresistive sensor element with a following electronic evaluξ˜‚
ation unit. Interfacing to the higher-level system is provided by 1 or 2 switching
outputs, an optional analogue output and an optional IO-Link interface.
The switching outputs can be configured for monitoring of a threshold value,
a pressure range or a differential pressure. The outputs can be set as PNP or NPN
and normally open (NO) or normally closed (NC). Via the IO-Link interface, process
values can be read out and parameters changed and transmitted to additional
devices.
3.1 Operating statuses
Operating status Function
RUN mode – Basic status after the operating voltage is switched on
– Display of the current measured value
SHOW mode – Display of the current settings
EDIT mode – Setting or modification of parameters
TEACH mode – Acceptance of the current measured value to determine switching
points
Fig. 4
3.2 Switching functions
Threshold value comparator for monitoring of a pressure threshold _|Β―
Function NO (normally open) NC (normally closed)
Switching function:
– 1 switching point (SP)
TEACH mode:
– 2 teach-in points (TP1, TP2)
– SP = Β½ (TP1+TP2) TP1 TP2
HY
1
0
Out
p
SP TP1 TP2
SP
HY
1
0
Out
p
Fig. 5
Window comparator for monitoring of a pressure range _|Β―|_
Function NO (normally open) NC (normally closed)
Switching function:
– 2 Switching points
(SP.Lo, SP.Hi)
TEACH mode1):
– 2 teach-in points (TP1, TP2)
– TP1 = SP.Lo, TP2 = SP.Hi
HY HY
TP1=SP.Lo TP2=SP.Hi
1
0
Out
p
HY HY
TP1=SP.Lo TP2=SP.Hi
1
0
Out
p
1) SP.Lo = smaller pressure/vacuum value, SP.Hi = larger pressure/vacuum value, dependent on the
Teach sequence
Fig. 6
Auto difference monitoring d_|Β―|_
This funciton permits monitoring of a pressure value for constancy.
If the applied pressure is constant in the range between [SP.Lo] and [SP.Hi], the referξ˜‚
ence pressure PRef is automatically determined. The result is a switching operation at
the output. The signal change signals the start of pressure monitoring.
If the pressure remains in the monitoring range [d.SP] around PRef, the pressure is
stable. When the monitoring range is left (e.g. caused by a leakage in the system),
the output switches back.
1 2
3
1Reference value is determined
2Measured value deviates by [d.SP] from the reference value
3Monitoring area
Fig. 7
The parameters [SP.Lo], [SP.Hi], [t.obS] and [d.SP] can be configured by the user.
The greater [t.obS] is set, the more constant the pressure signal must be to establish
the reference value PRef.
Function NO (normally open) NC (normally closed)
Switching function:
– 2 switching points (SP.Lo,
SP.Hi) for setting the valid
work range
– 1 switching point (d.SP)
for determination of
the monitoring area
TEACH mode1):
– 2 teach-in points (TP1, TP2)
– TP1 = SP.Lo, TP2 = SP.Hi
SP.Lo PRef SP.Hi
d.SP
1
0
Out
p
1
SP.Lo PRef SP.Hi
d.SP
0
Out
p
1) SP.Lo = smaller pressure value, SP.Hi = larger pressure value, independent of the Teach sequence
Fig. 8
4 Installation
Note
Installation and commissioning are to be carried out only by qualified personnel
in accordance with the operating instructions.
ξ˜ƒ Remove all transport packaging. The material used in the packaging has been
specifically chosen for its recyclability.
4.1 Mechanical and pneumatic
Note
An unfavourable mounting position can impair the function of the product.
ξ˜ƒ Mount the sensor so that no condensate from the compressed air lines can
gather in the device.
ξ˜ƒ Install the sensor so that it cannot be heated above the maximum permissible
operating temperature (plan for convection possibilities).
SPAN-...-G18M/R18M/N18M Mounting bracket
– Seal connecting thread.
max. 10 Nm
13 mm
max. 0,5 Nm
@ 3,3 mm
Fig. 9 Example with G18M Fig. 10 Example with SAMH-PU-A-. Fastening
SAMH-PN-W correspondingly
Front panel use SAMH-PN-F
– Size of the front panel cut-out in mm Γ¨ Fig. 11.
– Fasten panel frame to the sensor.
– Guide sensor from the front into the cut-out on the front panel.
– Attach the clamping element and press until it catches.
31 -0.4
31 -0.4
X
31 -0.4
X=31*n+3.5*(n-1)
s=max. 5 mm
1
2
1Panel frame
2Clamping element
Fig. 11 Fig. 12
4.2 Electrical
Warning
Use only power sources which guarantee reliable electrical isolation of the operξ˜‚
ating voltage in accordance with IEC/EN 60204-1. Consider also the general
requirements for PELV circuits in accordance with IEC/EN 60204-1.
ξ˜ƒ Connect sensor.
– Consider the maximum permissible line length: 30 m (20 m for IO-Link).
Pin Colour1) Allocation Plug L1
1 Brown (BN) Operating voltage +24 V DC 1 2 3 4
2 Black (BK) Switching output OutA or IO-Link
(C/Q line)
3 White (WH) Switching output OutB or
analogue output (pressure
signal InA)
4 Blue (BU) 0 V
1) Colours apply for connecting cables NEBS-L1... or electrical adapter SASC-P4... with NEBU-M8...
Fig. 13
Circuit diagrams
SPAN-...-PNLK-PNVBA SPAN-...-PN-PN
Fig. 14 Fig. 15
5 Commissioning
5.1 LCD display
1
3
2
1
45
1Output display
2Main display (e.ξ˜„g. measured
value)
3Status information
4Lower display (e.g. unit)
5Signal indicator
Fig. 16
Example for
LCD display
Meaning
Output display
[OutA] Switching output OutA selected (flashes with active IO-Link)
[OutA] Switching output OutA set
[OutB] Switching output OutB selected
[OutB] Switching output OutB set
Status information / signal indicator
[Lock] Security code activated ( Γ¨ Chap. 5.4)
[Spec] Special menu selected ( Γ¨ Chap. 5.6)
[InA] Pressure signal InA or analogue signal is selected
IIIIIIII Graphic bar graph in the lower display [Sub.d]
Fig. 17
Example for LCD display Meaning
Main display Lower display
Measured value indicator and unit in the RUN mode
[– 0.53] [bar] Measured value indicator (here: negative value) and unit
Menu for the switching outputs (OutA and OutB)
[Edit] [bin] Edit menu for the switching outputs (binary)
[Fctn] Threshold value comparator
[Fctn] Window comparator
d[Fctn] Auto difference monitoring
[1.80] [SP] Value of switching point (only for threshold value
comparator)
[2.45] [SP.Lo] Value of lower switching point
[6.45] [SP.Hi] Value of upper switching point
[0.50] [HY] Value of hysteresis
[18] [t.obS] / [MSEC] Time interval for determination of a mean value, which is
used to determine the pressure change and establish the
reference value.
[0.25] [d.SP] Threshold value of the differential pressure with auto
difference monitoring
[NO] [LOGC] Switching characteristics:
[NO] = normally open, [NC] = normally closed
[bLUE] [COLR] Display colour:
[bLUE] = Blue, colour change function deactivated
[R.ON] = Red, if switching output set
[R.OFF] = Red, if switching output not set
Note: Independent of the settings [COLR], the red colour
change appears with some malfunctions.
Extreme values (only SHOW mode)
[1.64] [MIN] Minimum measured pressure since switch-on or the last
reset
[8.50] [MAX] Maximum measured pressure since switch-on or the last
reset
Menu of the pressure signal (InA)
[Edit] [ANLG] Edit menu for the analogue output
[1 _ 5] [Out] / [V] Output function of the analogue output
[93] [In.Hi] / [%] Scaling of the analogue output in percent of the final
value of the pressure measuring range
[3] [In.Lo] / [%] Scaling of the analogue output in percent of the initial
value of the pressure measuring range
Menu for device settings (Spec)
[Edit] [MENU] Edit menu for additional settings
[16] [Filt] / [MSEC] Value of the filter time constant for the pressure
measurement signal
[bar] [Unit] Unit for the pressure indicator
[OFF] [Z.AdJ] [OFF] = zero point synchronisation (zero adjust)
deactivated
[ON] = offset correction for measured value indicator,
switching points and analogue output possible
[Unit] [Sub.d] Settings of the lower display in RUN mode: selected unit
or switching point of OutA or bar graph
[40] [Eco] / [SEC] Economy mode: period after which the display
background lighting is switched off
[PNP] [bin] / [Out] Shift of the switching outputs (binary) between PNP and
NPN
[bin] [Pin3] / [Out] Shift between switching output (binary) and analogue
output (lnA) at Pin3
[OFF] [Code] Activation and determination of the security code
[OFF] [MASt] Activation of the IO-Link master function for replication of
parameters
Fig. 18
5.2 Switch on sensor (RUN mode)
ξ˜ƒ Switch on the operating voltage.
Γ¨ Current measured value is displayed. The sensor is in the basic status
(RUN mode).
The basic status can be reached from other modes by:
– pressing edit button for 3 seconds
– expiration of a monitoring time (Timeout)
5.3 Displaying parameters (SHOW mode)
Requirement: The sensor is ready for operation (RUN mode).
Switching output OutA
ξ˜ƒ Press A-key.
Γ¨ The first parameter set is displayed. [Fctn] flashes.
The subsequent parameters can be displayed by repeatedly pressing the A key
(Γ¨ Fig. 19).
Γ¨ At the end, the min. and max. values are displayed. This can be reset with
the Edit key.
Switching output OutB or analogue output for pressure signal InA
ξ˜ƒ Press B-key.
Γ¨ The first parameter set is displayed. [Fctn] with OutB or [Out] with InA
flashes.
The subsequent parameters can be displayed by repeatedly pressing the B-key
(Γ¨ Fig. 19).
Measured value indicator (RUN mode)
OutA or OutB InA1)
(Switching output) (Analogue
output)
_|Β― _|Β―|_ d_|Β―|_ Out
Fctn Fctn Fctn
SP SP.Lo SP.Lo In.Hi
HY SP.Hi SP.Hi In.Lo
HY t.obS
d.SP
LOGC LOGC LOGC
COLR COLR COLR
MIN MIN MIN Reset
MAX MAX MAX Reset
Measured value indicator (RUN mode)
MIN, MAX: Parameter is displayed only for switching output OutA,
without Timeout
Edit button
A or B key
1)
Only SPAN-...-PNLK-PNVBA; via B-key
Fig. 19


Product specificaties

Merk: Festo
Categorie: Niet gecategoriseerd
Model: SPAN

Heb je hulp nodig?

Als je hulp nodig hebt met Festo SPAN stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Festo

Festo

Festo VPPI Handleiding

21 November 2024
Festo

Festo SFAB Handleiding

21 November 2024
Festo

Festo SFAH Handleiding

21 November 2024
Festo

Festo DRRD-12 Handleiding

21 November 2024
Festo

Festo SDE3 Handleiding

21 November 2024
Festo

Festo SFTE Handleiding

21 November 2024

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd