Extron WPB 109 Handleiding
Extron
Stopcontact
WPB 109
Lees hieronder de đź“– handleiding in het Nederlandse voor Extron WPB 109 (2 pagina's) in de categorie Stopcontact. Deze handleiding was nuttig voor 16 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/2
IMPORTANT:
Go to www.extron.com for the
complete user guide, installation
instructions, and specifications.
WPB 109 Wallplate • Installation Guide
The Extron WPB 109 wallplate is a single gang
pass-through wallplate with audio, VGA, and HDMI
connectors and 10-inch pigtails. It can be installed in
the supplied single gang mud ring or a junction box.
Install the wallplate directly into the wall using the
supplied mud ring or a UL-approved 1-gang junction
box (not supplied). Follow the steps in the “Installation”
section.
Planning - Check the Proposed Installation Location
Before starting the installation t is important that you do the following i :
WARNING: Failure to check these items may result in property damage, personal injury,
or both.
c Ensure there are no utility cables or pipes at the intended location that might be damaged
or cause injury when you are installing the device.
c Check that the installation meets the local and state regulatory requirements, including
building, electrical, and safety codes, and UL and ADA accessibility requirements.
During installation ensure the space behind the device is sufficient for the bend radius of the
pigtail. The recommended minimum bend radius is 2.4 inches.
WPB 109
HDMI
COMPUT ER
AUDIO
Front Side
Extron
WPB 109
Wall Mounting
Bracket
Locking Arms
WPB 109
HDMI
COMPUTER
AUDIO
Installation
1. Using the supplied mud ring or a junction box (not included) as a guide, mark and cut out
the appropriate material within the marked area.
2. Either:
zInsert the mud ring into the opening, rotate the
locking arms, and secure it with the supplied screws
(as shown at right), or
zInsert the junction box and secure it with nails or
screws.
3. Run the cables (video, audio, and HDMI) from the output
or input device locations (as applicable), behind the wall,
and to the WPB location, then thread the cables through
the mud ring or junction box.
4. Video — Insert the HDMI and VGA cable connector into
the appropriate connector on the pigtail.
NOTE: If using a DVI display with the WPB 109, connect a HDMIM-DVIDF adapter (part
number 26-617-01) and a separate audio cable.
5. Audio — Secure the output audio cable into the 3-pole captive screw connector. Wire as
described in “Cable Preparation for Audio Connections” on page 2.
NOTE: This may be easier to do before attaching the device to the mud ring.
6. Mount the cabled device into either the mud ring or the junction box.
CONTINUED ON SIDE 2
1
WPB 109 Wallplate • Installation Guide (Continued)
Extron Headquarters
+1.800.633.9876 (Inside USA/Canada Only)
Extron Asia
+65.6383.4400
Extron China
+86.21.3760.1568)
Extron Korea
+82.2.3444.1571
Extron Europe
+31.33.453.4040
Extron Japan
+81.3.3511.7655
Extron Middle East
+971.4.299.1800
Extron India
+91.80.3055.3777
© 2013 Extron Electronics — All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com
68-1162-50
Rev. A 01 13
Tip
Sleeve(s)
Ring
Ring
Tip
Tip
Sleeve
Sleeve
Tip
Unbalanced Input
TRS Connector
RCA Connector
Left
Right
Left
Right
Balanced Input or Output
Balanced Mono Audio
Unbalanced Stereo Audio
Balanced Audio
Wiring
Unbalanced Audio
Wiring
Source
Reference
Tip
Sleeve
Ring
Tip
Sleeve
Direct Insertion
Captive Screw
Unbalanced Output
Left
Tip
Sleeve(s)
NO Ground Here
NO Ground Here
Tip Right
CAUTION
For unbalanced audio, connect the
sleeve(s) to the ground contact.
DO NOT connect the sleeve(s) to the
negative (-) contacts.
Tip
Sleeve
NO Ground Here
Ring (R)
Ring
Tip (T)
Tip
Tip
Tip
Sleeve (S)
Ring (R) = Right Channel
Tip (T) = Left Channel
Sleeve (S)
(input or output)
(input or output)
Sleeve
Sleeve
Sleeve (S)
Ring (R)
Tip (T)
3.5 mm Audio Jack
TRS
Heat
Shrink 1/8"
(3 mm)
7/8"
(22 mm)
3/16" (5 mm) Max.
Cable Preparation For Audio Connections
The length of the exposed wires in the stripping process is critical.
The ideal length is . 3/16" (5 mm)
• If the stripped section of wire is longer than , the exposed 3/16"
wires may touch, causing a short circuit between them.
• If the stripped section of wire is shorter than , the wires can 3/16"
be easily pulled out even if tightly fastened by the captive screws.
Do not tin the wires!
Tinned wire does not hold its shape and can become
loose over time.
NOTE: Audio ground pins may be labeled as
or . The wiring and function are the same,
whichever way your product is labeled.
7. Connect the appropriate input or output devices to the front panel connectors.
8. Test the system and resolve any cabling or signal issues.
2
Product specificaties
Merk: | Extron |
Categorie: | Stopcontact |
Model: | WPB 109 |
Heb je hulp nodig?
Als je hulp nodig hebt met Extron WPB 109 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Stopcontact Extron
5 November 2024
25 September 2024
25 September 2024
15 Augustus 2024
15 Augustus 2024
14 Augustus 2024
14 Augustus 2024
14 Augustus 2024
7 Augustus 2023
Handleiding Stopcontact
- Stopcontact Philips
- Stopcontact IKEA
- Stopcontact Asus
- Stopcontact Apc
- Stopcontact AS - Schwabe
- Stopcontact Asrock
- Stopcontact AVM
- Stopcontact Bachmann
- Stopcontact Belkin
- Stopcontact Berker
- Stopcontact Bose
- Stopcontact Brennenstuhl
- Stopcontact Delta
- Stopcontact Denver
- Stopcontact Digitus
- Stopcontact Easy Home
- Stopcontact Ebode
- Stopcontact Elektrobock
- Stopcontact Gamma
- Stopcontact Gigabyte
- Stopcontact Gira
- Stopcontact Hager
- Stopcontact Hama
- Stopcontact InterBar
- Stopcontact Kathrein
- Stopcontact KlikaanKlikuit
- Stopcontact Kogan
- Stopcontact Kopp
- Stopcontact Logilink
- Stopcontact Manhattan
- Stopcontact Metz
- Stopcontact PCE
- Stopcontact Peerless
- Stopcontact Reer
- Stopcontact Schneider
- Stopcontact Showtec
- Stopcontact Silvercrest
- Stopcontact Silverline
- Stopcontact Smartwares
- Stopcontact V-Tac
- Stopcontact Vivanco
- Stopcontact Jung
- Stopcontact Osram
- Stopcontact Monoprice
- Stopcontact Niceboy
- Stopcontact Schwaiger
- Stopcontact Anslut
- Stopcontact EMOS
- Stopcontact Atlona
- Stopcontact Eurolite
- Stopcontact Savio
- Stopcontact Lenoxx
- Stopcontact Craftsman
- Stopcontact SPC
- Stopcontact Fibaro
- Stopcontact CyberPower
- Stopcontact Hazet
- Stopcontact AV:link
- Stopcontact Peerless-AV
- Stopcontact Busch-Jaeger
- Stopcontact ECS
- Stopcontact Homematic IP
- Stopcontact Lanberg
- Stopcontact Crestron
- Stopcontact Konig & Meyer
- Stopcontact ORNO
- Stopcontact PureLink
- Stopcontact Kramer
- Stopcontact Vimar
- Stopcontact Pancontrol
- Stopcontact Legrand
- Stopcontact Panduit
- Stopcontact InLine
- Stopcontact Phoenix Contact
- Stopcontact Metz Connect
- Stopcontact Leviton
- Stopcontact Neutrik
- Stopcontact DEHN
- Stopcontact Omnilux
- Stopcontact Heitronic
- Stopcontact Hoopzi
- Stopcontact Hall Research
- Stopcontact Crydom
- Stopcontact Adam Hall
- Stopcontact PS Audio
- Stopcontact Biostar
- Stopcontact 360 Electrical
- Stopcontact Bearware
Nieuwste handleidingen voor Stopcontact
22 November 2024
19 November 2024
19 November 2024
17 November 2024
17 November 2024
17 November 2024
17 November 2024
17 November 2024
17 November 2024
17 November 2024