Extron DVI DA2 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Extron DVI DA2 (5 pagina's) in de categorie Hifi systeem. Deze handleiding was nuttig voor 29 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/5
DVI DA2 and DVI DA 4 • User Guide
This guide describes the installation and operation of the Extron DVI DA2 and DVI DA4 Distribution Ampliers. Unless stated
otherwise, “distribution amplier” or “the unit” in this guide refer to both models.
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part15 of the
FCC rules. The ClassA limits provide reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used
in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause interference. This interference must be corrected at the expense of the user.
NOTE: For more information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related
topics, see the “ ” on the Extron website.
Extron Safety and Regulatory Compliance Guide
Specifications Availability
Product specications are available on the Extron website, www.extron.com.
About the DVI DA2 and DVI DA4
The Digital Visual Interface (DVI) Distribution Ampliers (DAs) have one input and either two (DVI DA2) or four (DVI DA4) outputs.
Output 1 for each model is for a local monitor and is used for Digital Display Channel (DDC) reference.
Both distribution ampliers accept one single link DVI-D input and drive two (DVI DA2) or four (DVI DA4) single link DVI-D output
signals.
12V
0.4A MAX
POWER
DVI- D INPUT DVI- D OUT PUT
1 2
DVI DA2
Extr
on
DVI DA
2
Distribution Amplier
PC
with DVI Output
Local Monitor
Flat Panel Display
with DVI Input
Figure 1. DVI DA2 Application Diagram
DVI DA2 and DVI DA4 Features
External power supply The DVI DA2 and DVI DA4 are powered by an external 12VDC power supply (provided with the
units).
DVI-D input — Both distribution ampliers accept one single link DVI-D input with a range of resolutions up to 1920 x 1200
or 1080p @ 60 Hz.
Input equalization — Input Equalization (EQ) conditions the input signals to ensure the integrity of the signals delivered to
the output devices.
DVI-D outputs — The units drive two (DVI DA2) or four (DVI DA4) single link DVI-D output signals.
1
DDC routing to the local monitor — Output 1 is used as a DDC reference and is labeled “Local Monitor” for easy reference.
The video source uses the bidirectonal DDC to communicate with the local monitor, which allows the source to determine the
resolution and refresh rate of the signal that it sends.
NOTES:
Since output 1 is used as the reference, all other display devices must be capable of handling resolutions equal to
or greater than that of the local monitor.
The actual signal transmission distance can vary greatly and depends on signal resolution, cable type, cable
quality, graphics card, and the display used in the system.
Versatile mounting options — Both units are 1U high, 3 inches (7.62 cm) deep, and 1/2rack (8.7 inches or 22.1 cm) wide,
allowing them to be conveniently mounted in a rack, mounted under a desk, or set on a tabletop.
Installation Overview
Both distribution ampliers can be placed on tabletops, or mounted under furniture or in racks by following these steps:
1. Turn off all electrical equipment. Make sure that the input sources, the DA and the output display(s) are all turned off and all
power sources and signal cables are disconnected.
2. Mount the unit (see page 5).Mounting
3. Connect the cables (see on page 3).DVI Connections
4. Plug in the (see page 3), then turn on the display devices and input devices.power supply
Front Panel Features
The front panels of the DVI DA2 and DVI DA4 are identical and shown in the illustration below
DVI DA SERIES
DVI DISTRIBUTION AMPLIFIER
1
Figure 2. DVI DA2 and DVI DA4 Front Panel (both models are identical)
a — On both the DVI DA2 and DVI DA4, the LED indicator lights when the unit is receiving power.LED indicator
Rear Panel Features
12V
0.4A MAX
POWER DVI-D INPUT DVI-D OUTPUT
LOCAL MONITOR
1 2
DVI DA2
12V
0.4A MAX
POWER DVI-D INPUT DVI-D OUTPUTS
LOCAL MONITOR
1234
DVI DA4
124 3
Figure 3. DVI DA2 (top) and DVI DA4 (bottom) Rear Panels
a Power input
b Input connector
c Output connector
d Local Monitor
connector
2
a Power input — Connect the provided power suppy to the 3.5 mm, captive screw
12V
0.4A MAX
PO WER
Power Supply
Output Cord
SECTION A–
A
RidgesSmooth
A A
DC Power Cord
Captive Screw Connector
AC Power Cord
Ground
+12 VDC
External
Power Supply
(12 VDC, 1 A )
power receptacle.
NOTES:
The length of the exposed wires in the stripping process is critical.
The ideal length is 3/16 inch (5 mm).
If the exposed section is , the exposed wires may touch, longer
causing a short circuit between them.
If it is , the wires can be easily pulled out, even if tightly shorter
fastened by the captive screws.
Do not tin the wires. Tinned wire does not hold its shape and can
become loose over time.
Figure 4. Power Connection
ATTENTION:
This product is intended to be supplied by a Listed Power Unit marked “Class 2” or “LPS,” rated 12 VDC, maximum
1.0 A. Always use a power supply supplied or specied by Extron. Use of an unauthorized power supply voids all
regulatory compliance certication and may cause damage to the supply and the end product.
Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or in wall cavities. The
power supply is to be located within the same vicinity as the Extron AV processing equipment in an ordinary location,
Pollution Degree 2, secured to the equipment rack within the dedicated closet, podium, or desk.
The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI/NFPA70,
article 75, and the Canadian Electrical Code part 1, section 16. The power supply shall not be permanently xed to
building structure or similar structure.
DVI Connections
b — Connect the input signal to the female DVI connector. The DVI input signal is equalized to ensure integrity.Input connector
c — Connect up to two (DVI DA2) or four (DVI DA4) DVI-D outputs to display devices, using the female DVI Output connectors
connectors.
NOTE: The outputs are not HDCP compatible.
d — Output 1 (Local Monitor) is used as a Hotplug Detect, a DDC clock, and a DDC data reference. Local Monitor connector
For the input device to provide a signal at the correct resolution and refresh rate, there must be a display device connected to
output1.
NOTE: Although the source device, local monitor, and remote display devices all connect to the distribution amplifiers
through DVI-I connectors, the DVI DA2 and DVI DA4 are compatible only with single-link DVI-D video signals.
To enable the units to accept sources providing HDMI signals or to provide signals to displays that accept HDMI signals,
use a HDMI to DVI adapter or cable, such as the Extron HDMIF-DVIDM female HDMI to male DVI-D adapter or the Extron
HDMIM-DVI-D M series of male HDMI to male DVI cables.
The input signal is one single link DVI-D with a resolution range up to 1920x1200 or 1080p@ 60 Hz.
Input EQ conditions input signals to ensure the integrity of the signals delivered to the output devices.
NOTES:
The actual signal transmission distance can vary and depends on the signal resolution, cable quality, graphics card, and
display used in the system.
To ensure proper operation, display devices connected to outputs 2 through 4 must be able to handle resolutions equal
or greater than that of the local monitor on output 1.
3
DVI DA2 and DVI DA 4 • Setup Guide (Continued)


Product specificaties

Merk: Extron
Categorie: Hifi systeem
Model: DVI DA2
Kleur van het product: Grey, White
Gewicht: 910 g
Ondersteunde video-modi: 1080p
Maximum resolutie: 1920 x 1200 Pixels
Volledige HD: Ja
Temperatuur bij opslag: -40 - 70 °C
Luchtvochtigheid bij opslag: 10 - 90 procent
Afmetingen (B x D x H): 191 x 267 x 76 mm
Video uit: 2x DVI
Aansluiting video: DVI
AC-ingangsspanning: 100-240 V
AC-ingangsfrequentie: 50 - 60 Hz
Bedrijfstemperatuur (T-T): 0 - 50 °C
Relatieve vochtigheid in bedrijf (V-V): 10 - 90 procent
Code geharmoniseerd systeem (HS): 85176990
Hoeveelheid Video ports: 3

Heb je hulp nodig?

Als je hulp nodig hebt met Extron DVI DA2 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Hifi systeem Extron

Extron

Extron DVI DA2 Handleiding

15 Augustus 2024

Handleiding Hifi systeem

Nieuwste handleidingen voor Hifi systeem

Lenoxx

Lenoxx CD813 Handleiding

16 November 2024
Denon

Denon CEOL N-8 Handleiding

16 November 2024
Fiio

Fiio M7K Handleiding

16 November 2024
Fiio

Fiio X1II Handleiding

16 November 2024
Fiio

Fiio M3 Handleiding

16 November 2024
Fiio

Fiio X3 Mark III Handleiding

16 November 2024
Samsung

Samsung MM-X7 Handleiding

15 November 2024