Extron CTU 100 Handleiding
Extron
Kabelstripper
CTU 100
Lees hieronder de 📖 handleiding in het Nederlandse voor Extron CTU 100 (5 pagina's) in de categorie Kabelstripper. Deze handleiding was nuttig voor 12 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/5
CTU 100
Universal Termination Compression Tool
User’s Guide
68-749-01 Rev. H
02 06
2CTU 100 Universal Termination Compression Tool
CTU 100 Universal Termination Compression Tool
Mini HR/
Mini 59
Illustration is not to scale.
NOTE
Outer
Insulation
Center
Conductor
Dielectric
1/4"
1/4"
Leave foil in place
(if present).
RG6/
RG59
For RG6 and RG59 cable only,
apply pressure to top and
bottom of cable stripper to cut
through outer insulation.
Braid
1/4"
Preparing the Cable
1. Insert the cable end into the properly sized hole (RG6 and
RG 59 in the larger hole, mini HR and mini 59 in the
smaller hole) in the cable stripper and line up the cable end
flush with the side of the tool. See the illustration at right.
2. Rotate the tool several times in one direction and then
several times in the opposite direction. For RG6 and RG 59
cables only, apply pressure. Do not over cut the braids.
3. Pull the cable out of the tool with the tool still closed.
4.For Mini HR and Mini 59 cables only, straighten and
smooth the stranded center conductor. Do not twist the
conductor. This will help deter crumpling or “frizzing” of
the stranded cable when the center pin is installed.
5. Ensure that the dielectric is rounded and that no braid is wrapped around the center core.
6. Fold back the braid. Do not remove the foil.
7.For RG59 HR plenum cable only, gently twist the foil to ensure that it is tighly molded to the
dielectric and that it is not peeled away from the dielectric.
Using the Universal Compression Tool and Adapters
(Adapters are used for terminating RCA and F-type connectors only)
If applicable, unscrew the adapter from
bottom of the compression tool.
Insert the connector into the plunger.
Compress the connector until you feel firm
resistance or the tool’s handle reaches the body.
If applicable, insert the adapter
into the plunger.
Two adapters, one gold and one
silver, are shipped with the
universal compression tool.
These adapters are required only
for RCA and F-type connectors.
See Part Numbers on
the rear page for proper
applications. Opened
For Mini HR or Mini 59 cable, use your fre
e
hand to push the cable into the toolfirmly
as you close the tool.
Ensure that the cable and connector
are centered over the plunger and go
straight into the plunger and not at an
angle.
Using the wrong adapter can damage the tool and/or connector.
Use no adapter for BNC connectors.
Use the gold adapter for gold RCA and F connectors only.
Use the silver adaper for nickel RCA and F connectors only.
Closed
CAUTION
1 2
3
4
Top View
Centered
Side View
Plastic
Dielectric
Sleeve
Compression
Sleeve
Center
Pin
Mini HR/
Mini 59
SuperFlex
Cable
1
2
3
5
5
4
Optional
Color
Ring
Compression
Connector
BNC Front
Ring
RG59 HR
Plenum
Cable
Center
Conductor
Optional
Color
Ring
5
RG59 HR
(Non-plenum)
/
RG6 SHR
Plenum or
Non-plenum
Cable
Center
Conductor
Optional
Color
Ring
Compression
Connector
Inner Sleeve
Inner Sleeve goes
over the dielectric and
under the braid.
Use compression
tool for leverage
Plastic
Slug
(discard)
RG59/RG6
Cable
Center Pin
Dielectric
Dielectric is
flush with inner
sleeve top.
Optional
Color
Ring
1
Terminating the Cable with BNC connectors
1.Mini HR and Mini 59 cable only — Slide
the center conductor pin onto the center
conductor.
2.Mini HR and Mini 59 cable only — Place
the plastic dielectric sleeve over the center
conductor pin.
3.Mini HR and Mini 59 cable only — Slide
the compression sleeve over the dielectric
sleeve as far as possible.
4.RG 59 HR plenum cable only — Slide the
barrel over the braid and outer insulation.
CAUTION
For RG 59 HR plenum cable,
ensure that the foil slides
cleanly into the ferrule and
does not bunch up. If the foil
does bunch up, you must cut
and restrip the cable and start
over.
5. Push the compression connector onto the
cable, gently twisting the cable in the
compression connector, until the center pin is flush with the BNC
front ring.
6. Place the cable and connector in the opened compression tool (no
adapter is necessary).
7. Compress the cable and connector together, as shown on page 2.
Terminating the Cable with F-type connectors
1. Push the compression connector onto the cable until
the dielectric is flush with the inner sleeve top of the
connector. Use the compression tool to provide
leverage as shown. The center conductor should
protrude slightly from the front ring. Discard the
plastic slug.
2. Select and place the correct adapter into the
compression tool. Use the
gold adapter for gold
connectors and the silver adapter for nickel
connectors.
CAUTION
Using the wrong adapter can damage the
tool and/or the connector.
3. Place the cable and connector in the opened
compression tool.
4. Compress the cable and connector together, as shown
on page 2.
RG59
Plenum
Cable
Coax Foil
Foil must go inside
compression sleve.
Compression
Sleve
3CTU 100 Universal Termination Compression Tool
Product specificaties
Merk: | Extron |
Categorie: | Kabelstripper |
Model: | CTU 100 |
Heb je hulp nodig?
Als je hulp nodig hebt met Extron CTU 100 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Kabelstripper Extron
14 Augustus 2024
Handleiding Kabelstripper
- Kabelstripper Ideal
- Kabelstripper Milwaukee
- Kabelstripper Ryobi
- Kabelstripper Velleman
- Kabelstripper Steren
- Kabelstripper Televés
- Kabelstripper Panduit
- Kabelstripper Jokari
- Kabelstripper Knipex
Nieuwste handleidingen voor Kabelstripper
16 November 2024
16 November 2024
26 Juli 2023
26 Juli 2023
5 Juli 2023
4 Juli 2023
28 Juni 2023
28 Juni 2023
27 Juni 2023
6 Juni 2023