Extralife Instruments Super Sixteen Handleiding


Lees hieronder de đź“– handleiding in het Nederlandse voor Extralife Instruments Super Sixteen (15 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 31 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/15
extralife instruments
Owner’s manual v1.1
Documents available at:
http://extralifeinstruments.com/
PITCH Adjusts
pitch output for
selected step.
Range +/- 12
semitones
DATA this stepped
encoder adjusts the
selected sequence
parameter, like patch
number or tempo.
CLOCK input accepts
a 1-pulse-per-step clock
signal and advances the
sequencer in sync to
external gear.
RESET input
accepts a pulse to
restart the sequence
at the beginning, for
synchronized looping.
CV output sends
out an unquantized
control voltage
controlled by the CV
parameter for each
step (0-8v)
PITCH output sends
quantized control
voltage set by the
PITCH and OCTAVE
parameters for each
step (0-8v)
GATE output sends
5V gate signals for
each active step, the
duration of which is
set by each step’s
LENGTH parameter
STEP BUTTONS
select and toggle steps
on and o󰀨. Press once
to select and again to
toggle. Inactive steps are
activated automatically
when selected.
RECORD enables
motion recording. Press
and hold while adjusting
PITCH, OCTAVE,
LENGTH, or CV to
record changes to the
currently playing steps in
realtime.
MUTATE activates
the selected “mutation”
e󰀨ect. Adjust DATA while
holding MUTATE to
change the e󰀨ect depth.
OCTAVE Adjusts
pitch output for
selected step in
increments of 12
steps. Range +/- 4.
LENGTH Adjusts
the duration of the
selected step, as
a percentage of a
single step’s length.
Range 0-400%.
CV Adjusts the
value of the
secondary CV
output for the
selected step.
Range 0-100%
GLIDE Activates
portamento, or
a “slide” to the
selected note over
its duration.
SUPER SIXTEEN
SHIFT Press [SHIFT] plus another
button simultaneously to access its
secondary or “shift” function (these
are outlined in black labels on the
panel). Buttons that have shift
functions include Steps 9-16, Record,
Mutate, Glide, and Play. When
you are editing a parameter, press
[SHIFT] again to exit back to the
main note data display.
PLAY Start or stop the internal
sequencer playback. [SHIFT]+Play
resets to the start, the same as a
pulse to the RESET input. A pulse to
the CLOCK input will stop the internal
sequencer.
Note: Pressing play while the
CLOCK input is receiving a signal
generally has no e󰀨ect - if the internal
tempo is set much faster than the
external clock, however, pressing
play may cause the sequencer to
gain a step relative to the external
clock before it syncs again.
LOAD/SAVE enables you to save the active
sequence or load a new one. To save a
sequence to memory, press once, and SAVE
then use the knob to choose the PATCH DATA
NUMBER (1-99) [0-99] where this sequence
will be saved. To conîšżrm it, press SAVE
again. Press [SHIFT] to cancel saving. Once
saved, the sequence can be recalled at any
time. It’s a good idea to save your sequences
frequently, since it’s easy to radically alter the
patch memory.
Note: While selecting a patch number, the
decimal point after the number indicates
that there is already a sequence saved at that
patch number.
Once you’ve chosen a PATCH NUMBER
to save your sequence, you can double-tap
SAVE to overwrite it with the active sequence.
Get in the habit of doing this whenever you
make a change you like! You can likewise
double-tap to reload the last-saved LOAD
sequence if you make a change you dislike.
To load a sequence, press once, and LOAD
then use the knob to choose a PATCH DATA
NUMBER to load. Press again to LOAD
conîšżrm and load the sequence
Note:If there is no sequence in that patch
number, a blank sequence will be loaded.
When a new sequence is loaded, the
sequence will “pick up” playback in real-time at
the same place in the last bar of the sequence,
making synchronized songs and pickup
phrasing dead simple.
1. Sequence controls
2. Step editing
Step editing is accomplished by pressing the the 16 step
buttons in the center of the panel. The LEDs adjacent
to each button indicate whether that step is active or
inactive. This display indicates the 16-step rhythm of the
sequence.When selected for editing, its LED will on blink
and o󰀨. If the selective step is active, it will be mostly on
and blink o󰀨 briey. If it’s inactive, it will be mostly o󰀨 and
blink on briey.
To select a step, press the corresponding
button .once
If inactive, that step will be automatically
activated when selected. To deactivate a
step, press it again.
Once a step is selected, you can edit its
PITCH, OCTAVE, DURATION, CV, and
GLIDE values with the corresponding
knobs and button on the right side of the
panel. These values only change when the
knobs are moved and the display updates
to reect the new value. When a step is
selected, the display will update to show its
value for the last edited parameter.
Only active steps will trigger the gate
output and change the PITCH/CV outputs.
Inactive steps do not have any e󰀨ect on
the seqeuncer, but their values are saved
with the sequence.
While the sequencer is playing, the LEDS
will blink as each step is played to show a
“Running light” indicating the current step.
Tap once to select/activate a step
Tap again to deactivate
Press a button to select a
step then edit it by turning
the knobs.
PITCH & OCTAVE
together control the Pitch
output voltage.
CV controls the CV
output voltage.
DURATION controls the
length of the pulse sent
to the GATE output.


Product specificaties

Merk: Extralife Instruments
Categorie: Niet gecategoriseerd
Model: Super Sixteen

Heb je hulp nodig?

Als je hulp nodig hebt met Extralife Instruments Super Sixteen stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Extralife Instruments

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd