Etekcity MSR-500 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Etekcity MSR-500 (20 pagina's) in de categorie Multimeter. Deze handleiding was nuttig voor 9 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/20
Digital Multimeter
Model No.: MSR-R500
Questions or Concerns?
(855) 686-3835 • support@etekcity.com
Thank you for purchasing the Etekcity® MSR-R500
Digital Multimeter. Measure DC and AC voltage, current,
diode and audible continuity, and resistance with the
convenience of one single tool with built-in overload
protection.
Safe and Proper Usage
WARNING: TO AVOID THE RISK OF ELECTRIC
SHOCK OR THE DAMAGE OF THE MULTIMETER OR
OTHER EQUIPMENT, DO NOT CONNECT TO ANY
INPUT TERMINALS OF THE MULTIMETER THAT
MAY EXCEED 500V.
Read all the instructions provided in this manual.
Failure to comply with the instructions in the manual
and/or use of the device in ways other than the ones
mentioned in the manual may result in serious injury,
fire, and/or electrical shock. The person responsible for
this equipment must ensure that all users understand
the directions and adhere to them.
This meter complies with standard IEC61010: in
pollution degree 2, overvoltage category (CAT I 600V,
CAT II 300V) and double insulation.
CAT I: Signal level, special equipment or parts of
equipment, telecommunications, electronic, etc.
CAT II: Local level, appliance, PORTABLE EQUIPMENT
etc., with smaller transient overvoltages than CAT III.
Safety Operating Procedures
• Be sure to read, understand and comply with all the
instructions in this manual.
• Make sure the test leads are in a safe state. Keep
- 1 -
equipment out of humidity or moist environments.
• DO NOT use the meter if it is damaged or the case (or
part of the case) is removed. Look for cracks or
missing plastic. Check the insulation around the
connectors before use.
• DO NOT use the equipment in wet environments.
• Remove the test probes from the item of
measurement before changing the settings or
measurement functions on the multimeter.
• DO NOT apply the multimeter to voltages that may
exceed 500V.
• DO NOT measure voltages when the meter is set to
measure resistance ( ).Ω
• Always use the fuses of the correct type as specified
within the instructions to avoid any injury, electrical
shock, or risk of fire.
• DO NOT operate the meter around explosive gas,
vapor, or dust.
• When operating the test probes, keep your fingers
behind the finger guards.
• When making electrical connections, connect the
common test lead (black) before connecting the live
test lead (red). When disconnecting, disconnect the
live test lead (red) before disconnecting the common
test lead (black).
• Always remove the test leads before replacing the
battery within the multimeter or opening the battery
compartment.
• Inspect the condition of the test leads and the
multimeter for any damage before operating the
meter. Repair or replace any damage before use.
• Verify the meter’s operation by measuring a known
voltage before and after using the meter.
• DO NOT change the settings on the rotary switch
while the test leads are measuring a source of power.
• Use great care when making measurements if the
- 2 -


Product specificaties

Merk: Etekcity
Categorie: Multimeter
Model: MSR-500

Heb je hulp nodig?

Als je hulp nodig hebt met Etekcity MSR-500 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Multimeter Etekcity

Etekcity

Etekcity MSR-500 Handleiding

20 Februari 2024

Handleiding Multimeter

Nieuwste handleidingen voor Multimeter