TECHNICAL SPECIFICATIONS
ENDA EPA242 PROGRAMMABLE AC/DC AMMETER
Read this document carefully before using this device. The guarantee will be expired by damaging of the device if you don't
attend to the directions in the user manual. Also we don't accept any compensations for personal injury, material damage or
capital disadvantages.
77 x 35mm sized
4 digits display
Easy to use with front panel keypad
Programmable scale between 5A and 9999A
Multifunctional alarm output (NO+NC) for upper and lower limits
Communication feature over isolated RS485, using ModBus RTU protocol ( )
Measuring type can be selected as AC, DC or true RMS
Key lock feature
0-20mA, 4-20mA, 0-10V or 1-5V Output selection (For only “A” type output devices)
CE marked according to European Norms
5A or 60mV, CT20/30 Current Transformer or 60mV input (Specify at Order)
(Optional)
Optional
Thank you for choosing rogrammable AC/DC mmeterENDA EPA242 P A
ENVIRONMENTAL CONDITIONS
Height Max. 2000m
80 up to 31Relative humidity for temperatures% °C decreasing linearly 50% at 40°C., to
Ambient/stroge temperature
Max. Relative humidity
0 ... +50°C/-25 ... 70°C
Rated pollution degree According to EN 60529 Front panel : IP6 , Rear5 panel : IP20
Do not use the device in locations subject to corrosive and ammable gases.
Order Code : EPA242 - - - -
1 3 4
2 - Output
R..........Relay
A...........Analog Output
Blank....No Output
4 Isolated ModBus -
RS ...... ModBus
( )
I Isolated
Specify at Order .
3 - Supply Voltage
230VAC...230V AC
110VAC...110V AC
24VAC.....24V AC
SM...........9-30V DC / 7-24V AC
2
1 - Input
CT.......CT20/30 Current
Transformer Input or 60mV
Blank....5A or 60mV
While input type in 5A / 60mv ; = 0A...5A 0A...9999A ( Determined by parameter. e.g ; If , scale is )c.tr.r c.tr.r 5
0.002A x ( e.g ; For , sensitivity is )c.tr.r 5 = 0.01A
c.tr.r
AC
RMS
DC
1
40k
2mΩ
Ω
AC and RMS
DC
%1
±
and
and
129
1110
%1
±
%1
±
and
and
129
1110
While input type in CT20/30 / 60mV ;
= 0A...300A = 0A...300A
= 0A...120A = 0A...120A
= 0A..9999A = 0A...5A
If , input range is ( Determined by parameter. e.g ; If , scale is )
If , input range is ( Determined by parameter. e.g ; If , scale is )
If , input range is (Determined by parameter. e.g ; If , scale is )
ityp Ct20 turn turn 1
ityp Ct30 turn turn 1
ityp 5Hnt c.tr.r c.tr.r 5
ELECTRICAL CHARACTERISTICS
Supply
Power consumption
Wiring
Scale
EMC
Safety equirementsR
Input Impedance
Frequency Range
Input Range
Sensitivity
Accuracy
230V AC +10% -20%, 50/60Hz or 24V AC 10% , 50/60Hz or optional 9-30V DC / 7-24V AC 10% SMPS
± ±
Max. VA5
2.5mm² screw-terminal connections
While input type in 5A / 60mv ; = -5A...5A -999A...9999A ( Determined by parameter. e.g ; If , scale is )c.tr.r c.tr.r 5
While input type in CT20/30 / 60mV ;
= 0A..9999A = -5A...5A
DC Measurement can not be performed by using current transformer.
If , input range is (Determined by parameter. e.g ; If , scale is )ityp 5Hnt c.tr.r c.tr.r 5
(full scale) ( For square wave form)± 2%
(full scale)
(full scale) ( For square wave form)± 2%
or CT20/30 input devices 0....150mA-5A...5A
-60mV...60mV
( Device 10A current )
( Device 50V voltage )
may be damaged at and above s
may be damaged at and above s
EN 61326-1: 2013
EN 61010-1: 20 (Pollution degree 2, overvoltage category II)10
DC , 10Hz - 200Hz ( For square wave form)10Hz - 70Hz
Mechanical 30.000.000 ; Electrical 100.000 operation.
OUTPUTS
Alarm output Relay: 250V AC, 8A (for resistive load), NO+NC
Life expectancy for relay
outputAnalog 0-20mA DC, 4-20mA DC, 0-10V DC 1-5V DC . ( Ω)or selection Load resistance for current outputs are max. 500
HOUSING
Housing type Suitable for flush-panel mounting. (According to DIN 43 700)
Dimensions W7 xH xD mm7 35 61
Weight
Enclosure material Self extinguishing plastics.
Approx. 50g (after packing)2
While cleaning the device, solvents (thinner, , acid etc.) or corrosive materials must not be used.gasoline
CT20/30 Current Transformer must be ordered separately.
SET
EPA242
ENDA
OUT AC DC ACDC
A
0.000
english
EPA242-E-290319
1. / 4
E-mail : info@suran-elektronik.de
Internet : www.suran-elektronik.de
Tel.: +49 (0)7451 / 625 617
Fax: +49 (0)7451 / 625 0650
SURAN Industrieelektronik
Dettinger Str. 9 / D-72160 Horb a.N
:Note
1)
2)
Panel thickness should be maximum mm.
mm free space
, it would be dicult
to remove it from the panel.
7
There must be at least 60
behind the device otherwise
71,5mm
2
61mm 5mm
1
Panel cut-out
Equipment is protected throughout by DOUBLE
INSULATION Holding screw 0.4-0.5Nm.
Depth Push the ush-mounting
clamp in direction as
shown in the gure left.
Then, pull out the clamp in
direction
-
1
-
2.
For removing mounting clamps :
Rubber packing
Flush mounting
clamp Panel
DIMENSIONS
CONNECTION DIAGRAM
ENDA EPA242 is intended for installation in control panels. Make sure that the device is used only for intended purpose.The electrical
connections must be carried on by a qualied sta and must be according to the relevant locally applicable regulations. During an
installation, all of the cables that are connected to the device must be free of electrical power. The device must be protected against
inadmissible humidity, vibrations and severe soiling. Make sure that the operation temperature is not exceeded. The cables should not
be close to the power cables or components.
SUPPLY:
NOTE :
4
5
184-253V AC
50/60Hz 7VA
Line
Neutral
230V AC
Supply
Switch
Cable size: 1,5mm²
Fuse
F 100mA
250V AC
Fuse should be connected.
1) Mains supply cords shall meet the requirements of IEC 60227
or IEC 60245.
2) In accordance with the safety regulations, the power supply
switch shall bring the identication of the relevant instrument
and it should be easily accessible by the operator.
CAUTION :
If 5A / CT20-30 and 60mV inputs are connected at the same time, the measurement will be incorrect.
77mm
SETSET
EPA242
ENDA
OUT AC DC ACDC
A
0.000
CAT II
+
5AMax.
AC / DC
1 2 3 4 5 6 7 8 9 10
ENDA INDUSTRIAL ELECTRONICS
SN: XXXXXXXXX
EPA242-230VAC
PROGRAMMAB LE
AC/DC AMMETE R
11 12
680407704309
230V AC +1 0% -20%
50/60Hz 5VA
Made in Turkey
+Max.
AC / DC
60mV
CAT II
+
Max.
AC / DC
5A
1 2 3 4 5 6 7 8 9 10
ENDA INDUSTRIAL ELECTRONICS
SN: XXXXXXXXX
EPA242-230VAC
PROGRAMMABLE
AC/DC AMMETER
11 12
8 680407 704 3 09
230V AC +10% -20%
50/60Hz 5VA
Made in Turkey
+Max.
AC / DC
60mV
CAT II
+
Max. 5A
AC / DC
1 2 3 4 5 6 7 8 9 10
ENDA INDUSTRIAL ELECTRONICS
SN: XXXXXXXXX
EPA242-230VAC-RSI
PROGRAMMABLE
AC/DC AMMETER
11 12
COM.
B
A
8 680407 704 3 16
230V AC +10% -20%
50/60Hz 5VA
Made in Turkey
+Max.
AC / DC
60mV
CAT II
+
CT20/30
AC / DC
1 2 3 4 5 6 7 8 9 10
ENDA INDUSTRIAL ELECTRONICS
SN: XXXXXXXXX
EPA242-CT-R-230VAC-RSI
PROGRAMMABLE
AC/DC AMMETER
11 12
OUTPUT
250V AC 8A
RESISTIVE LOAD
8 680407 704 3 23
230V AC +10% -20%
50/60Hz 5VA
Made in Turkey
+Max.
AC / DC
60mV
CAT II
+
Max. 5A
AC / DC
1 2 3 4 5 6 7 8 9 10
ENDA INDUSTRIAL ELECTRONICS
SN: XXXXXXXXX
11 12
OUTPUT
250V AC 8A
RESISTIVE LOAD
COM. B
A
8 680407 704 3 30
230V AC +10% -20%
50/60Hz 5VA
Made in Turkey
+Max.
AC / DC
60mV
EPA242-R-230VAC-RSI
PROGRAMMABLE
AC/DC AMMETER
CAT II
+
CT20/30
AC / DC
1 2 3 4 5 6 7 8 9 10
ENDA INDUSTRIAL ELECTRONICS
SN: XXXXXXXXX
EPA242-CT-A-230VAC
PROGRAMMABLE
AC/DC AMMETER
11 12
8 680407 704 3 23
230V AC +10% -20%
50/60Hz 5VA
Made in Turkey
+Max.
AC / DC
60mV
CAT II
+
Max. 5A
AC / DC
1 2 3 4 5 6 7 8 9 10
ENDA INDUSTRIAL ELECTRONICS
SN: XXXXXXXXX
11 12
COM.
B A
8 680407 704 3 30
230V AC +10% -20%
50/60Hz 5VA
Made in Turkey
+Max.
AC / DC
60mV
EPA242-A-230VAC-RSI
PROGRAMMABLE
AC/DC AMMETER
COM.
B
B A
Measurement input 0-300A Measurement input 0-120A
TC 20 TC 30
CT20 CT30
A
-A
0
A
0
A
0
A
-A
A
0
T3T/2T/2 2T
T 3T/2T/2 2T
T 3T/2T/2 2T
T3T/2T/2
0
T 3T/2T/2 2T
0.308 A
0.386 A
A
0.000
A
0.000
1
2
A1
2
A
2
A1
2
Aπ
1
2
A
1
Aπ
2
A1
2
A1
2
A1
ac Ac.dcdc (rms)
A
0
A
-A
0
T
3T/2T/2
2T
d d
T 2T 0.000
d
T
d
T
AA
d
T
Ad
T2
2
3
A1
3
A1
E-mail : info@suran-elektronik.de
Internet : www.suran-elektronik.de
Tel.: +49 (0)7451 / 625 617
Fax: +49 (0)7451 / 625 0650
SURAN Industrieelektronik
Dettinger Str. 9 / D-72160 Horb a.N
E-mail : info@suran-elektronik.de
Internet : www.suran-elektronik.de
Tel.: +49 (0)7451 / 625 617
Fax: +49 (0)7451 / 625 0650
SURAN Industrieelektronik
Dettinger Str. 9 / D-72160 Horb a.N
EPA242-E-290319
2. / 4
UP.l1
UP.l1 HYS.U +
LO.l1
LO.l1 HYS.L
+
OUT1
OUT1
dly.U
A.out n.c.
=
A.out n.o. =
dly.U dly.ldly.l
Input
t
t
t
OUTPUT CHART
ConF Out1
tYpE
d.pnt
Opnt
Adr5
bAUd
UPLL
HYSU
dLYU
LOLL
HYSL
Samping Time
If 1 ( ) is selected ; sampling time of the measurement is 250ms,
If 2 ( ) is selected, it is 500ms. If 3 ( ) is selected, it is 750ms.
If 4 ( ) is selected, it is 1 second.
1
2 3
4
Device Address
It can be adjusted between - .1 247
B Rateaud
It can be adjusted as , , , , , ,
, and
OFF 1200 2400 4800 9600 19200
38400 57600 115200 .
OtYp
dLyL
Out1 Output
It can be adjusted as or If is selected, incase of
alarm, out relay is activated.
n.o. N.c. n.o
Upper Limit Value
It can be adjusted between minimum and maximum scale that is
specied with parameter. This parameter can’t be lower than
( )
c.tr.r
l0ll - HY5U - HY5L
Hysteresis Value for Upper Limit
It can be adjusted between and parameter. This
parameter can’t be higher than ( ).
When changed, gets the value of .
0 ctrr /5
- - HY5L
ctrr HY5U 0.1
Upll l0ll
Delay Time for Upper Limit Alarm
It can be adjusted between and .0 900
Lower Limit Value
It can be adjusted between lower scale and upper scale that is specied with
parameter.
This parameter can’t be higher than ( ) value.
c.tr.r
UPLL - HY5U - HY5L
Hysteresis Value for Lower Limit
It can be adjusted between and . This parameter can’t be
higher than ( ) value. When is
changed, gets the value of .
0 Ctrr /5
- - ctrr
HY5U 0.1
UPLL L0LL HY5U
Delay Time for Lower Limit Alarm
It can be adjusted between and seconds.0 900
iIncludes in R extension devices.
SETSET
EPA242
ENDA
OUT AC DC ACDC
A
0.000
& &
SET
SET
&
Used for displaying and conguring the selected parameter value.
Programming
key
Used for increasing the setpoint value and changing parameters.
When held down for a few seconds, congured numeric value increases faster.
Used for decreasing the setpoint value and changing parameters.
When held down for a few seconds, congured numeric value increases faster.
Increment
key
Decrement
key
SET
If these keys are pressed and held for 3 seconds, “Programming Mode” is entered or it returns to “Running Mode”. If and keys are pressed
while parameter names are displayed, than it returns to measured value.
PROGRAMMING MODE
Current Conversion Ratio
It can be adjusted between and (/5). If this parameter
changes, upper limit value is set to maximum scale ,minimum limit value is
set to minimum scale and hysteresis values are set to .
5.00(/5)
0.1
9999
Measuring Method
It can be adjusted , orto ac dc acdc. LEDs on the top of the display
indicates the adjusted measurement method.
Decimal Indicator
Decimal point moves automatically according to displayed value on
the screen.
0
If measured value is lower than 10, it can be shown
( ) , ( ) , ( ) or ( ).
measured value between 10 and 100 it can be shown as
( ) ,( ) or ( ).
If measured value between 100 and 1000, it can be shown as
( ) or ( ) .
as
If ,
0.0 0 0.00 0.0 0
0.00 0.0 0
0.0 0
Delay Time for Initial Upper Limit Alarm
It can be adjusted between and seconds.0 900
5dly
ityP
turn
AtyP
Input Type ( In devices with input type "CT" )
Can be adjusted to , and values.Ct20 CT30 5HNt
5HntIf is selected, 60mV input terminal must be used.
Number of Windings ( In devices with input type "CT" )
Number of windings of the current cable getting through the CT20/30
current transformer.
Please see "CT20/30 Current Transformer & Windings" chart on
the right of this page.
Analog Output Status ( In devices with output type "Analog" )
Can be adjusted to , , and values.0 - 20 4 -20 0 -10 1 - 5
PROGRAMMING DIAGRAM
Measured Value
L0C UL0C0.00
LOCKING & UNLOCKING KEYPAD
SET
UPLL LOLL 0.00
0.00
+
By pressing to key for 3 seconds, quick menu is entered.
QUICK MENU
& & 01.01 2015
Year
Day.Month
If these keys are pressed and held together, revision
date appears as day, month and year.
SET
0.00
REVISION NUMBER
& &
SET
While revision information displayed and if one of the pressed key
is released, measured value is displayed again.
Measured Value
Measured Value
Measured Value
In “Running Mode” , by pressing to key for 3 seconds, keypad locked or unlocked.
SET
Powered on device by pressing key. message appears
on display and device reset to default settings.
dPAr
DEFAULT SETTINGS
CT20/30 Current Transformer & Windings Chart
Note :
If = , parameter is not appears.
If = or , parameter is not appears.
ityp 5hnt turn
ityp Ct20 Ct30 ctrr
Note :
Before setting the relay parameters, the operating scale must be
determined from parameter.
If , and parameters are changed, ,
, and values must be checked.
dpnt
dpnt typE Ityp Upll
loll Hy5U Hy5l
Measured current value is
higher than maximum scale.
Measured current value is
lower than minimum scale.
ERROR MESSAGES
SET
SETTING UP THE PARAMETERS
tYPE dC ACdC
If key is pressed, the current value of the parameter appears by ashing on the display.
SET
After the setting up the parameters, if set key is pressed again, adjusted parameter
name appears on display.
By using “UP” or “DOWN” navigation keys, selected parameter can be adjusted to
the desired value.
SET
SET
E-mail : info@suran-elektronik.de
Internet : www.suran-elektronik.de
Tel.: +49 (0)7451 / 625 617
Fax: +49 (0)7451 / 625 0650
SURAN Industrieelektronik
Dettinger Str. 9 / D-72160 Horb a.N
E-mail : info@suran-elektronik.de
Internet : www.suran-elektronik.de
Tel.: +49 (0)7451 / 625 617
Fax: +49 (0)7451 / 625 0650
SURAN Industrieelektronik
Dettinger Str. 9 / D-72160 Horb a.N
EPA242-E-290319
3. / 4
turn
I max(A)in
1 2 3 4 5 6
C 20T
CT30
300
I max(A)in 150 100 75 60 50
120 60 40 30 24 20
7 8 9 10
42,8 37,5 33,3 30
17,1 15 13,3 12


Product specificaties

Merk: Enda
Categorie: Meetapparatuur
Model: EPA133

Heb je hulp nodig?

Als je hulp nodig hebt met Enda EPA133 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Meetapparatuur Enda

Handleiding Meetapparatuur

Nieuwste handleidingen voor Meetapparatuur