M0014A | VT-310
GB Voltage Tester
CZ Zkoušečka napětí
SK Skúšačka napätia
PL Tester napięcia
HU Feszültségmérő
SI Preizkuševalec napetosti
RS|HR|BA|ME Ispitivač napona
DE Spannungsprüfer
UA Тестер напруги
RO Tester de tensiune
LT Įtampos testeris
LV Sprieguma testeris
EE Pingetester
BG Тестер за напрежение
2
B
AC110V~400V
AC110V~400V
L
C
N
AC230V
L N
D
EAC230V
L N
F
G
+
-
H
+-
I
1
2
8
3
49
6
5
7
A
GB | Voltage Tester
The VT-310 tester is designed for two-pole measurement of voltage in DC and AC circuits
between 110 and 400 V with a frequency of 0–60 Hz, in order to identify the phase
conductor, the phase sequence in a three-phase system with neutral conductor and to
determine the polarity of DC voltage.
The tester meets the requirements of standard EN 61243-3:2014, in range 110–400 V/
CAT III 400 V, with protection rating of IP54.
Its range of working temperatures is -10 °C to +50 °C, humidity 20–96 %.
The tester can be used for making measurements in electrical wiring and devices falling
within overvoltage category CAT III 400 V.
Overvoltage category CAT III also includes category CAT II for electrical devices and
equipment with special requirements on their safety and usability.
These are, for instance, domestic wiring, protective installations, power outlets, switches,
circuit breakers etc.
Description of Tester
1. Mobile measuring tip
2. Slider
3. Measuring tip of the tester
4. Glow lamp
5. Tester guard
6. Polarity LEDs
7. AC voltage gauge
3
8. Metal pin
9. Tester lug
When measuring with the mobile measuring tip, you must move the slider down to
expose the metal tip; .see gure B
Voltage Indication
The amount of voltage in the circuit is indicated by an electromagnet which pulls in
a sprung iron core. The indicator will show the voltage values on a scale (both LEDs
glow). .See gure C
Identifying the Phase Conductor
The identication of the phase conductor is performed using the glow lamp in the left-
side window of the tester. Hold the tester so that your hand is touching the metal pin
on the rear of the cover and place the measuring tip onto the phase conductor. If phase
voltage is detected on the conductor, the glow lamp will turn on. The current passing
through the body is below 0.25 mA. See gure D, E.
Determining the Phase Sequence
Phase sequence is determined using the glow lamp and a circuit consisting of resistors
and capacitors which creates voltage depending on the direction of the phase rotation.
The hand touches the metal protrusion on the rear of the tester. Placing the xed tip
on the preceding phase and the mobile tip onto the following phase turns on the glow
lamp. In the reverse phase sequence, the glow lamp will be o (LEDs on). See gure F, G.
Determining the Polarity of DC Voltage
The polarity of DC voltage is indicated by two LEDs. If the positive pole is located on the
mobile measuring tip, the red "+" diode will light up; see gure H.
If the negative pole is located on the mobile measuring tip, the green "–" diode will
light up; .see gure I
WARNING
Do not use the device if the leads or cover are damaged.
The device may only be operated by a responsible and trained person.
Do not test voltage through contact if you do not know the exact voltage in the
circuit!
ATTENTION! The measurement time must not be longer than 10 seconds, especially
in higher voltages.
The maximum measurement time must not exceed 30 seconds or the device will
be damaged.
A pause of 240 seconds must follow after each measurement.
When measuring, hold the probe by the mechanical guard on the tester body. This
will prevent accidental contact with the metal portion of the probe, which could
otherwise cause injury by electric current during measurement.
The voltage listed on the tester is nominal voltage. The tester may only be used in
installations with the listed nominal voltage.
The tester can only be used for testing voltages above the ELV threshold (Extra
low voltage).
The tester must be checked before and after testing. If the indicators on the tester
are failing, the tester must not be used.
In case of usage on higher voltage than prescribed, the electromagnetic coil may
become damaged and the tester would become unusable.
Do not modify the measuring tips or any other parts of the tester. If the tester is
malfunctioning or otherwise damaged, have it repaired in a professional repair shop.
Do not use the tester if its components are wet.
Maintenance
The tester is designed to require no service on any of its components and is mainte-
nance-free.
Cleaning:
-Occasionally wipe the tester with a soft moistened cloth and common home deter
gent. Do not use aggressive solvents.
Prevent ingress of water into the interior of the device to protect the device against
short circuits and other types of damage.
This device is not intended for use by persons (including children) whose physical, sensory
or mental disability or lack of experience and knowledge prevents safe use, unless they
are supervised or instructed regarding use of the appliance by a person responsible for
their safety. Children must always be supervised and must never play with the device.
Do not dispose with domestic waste. Use special collection points for sorted waste.
Contact local authorities for information about collection points. If the electronic
devices would be disposed on landll, dangerous substances may reach ground-
water and subsequently food chain, where it could aect human health.
Emos spol s.r.o. declares that the VT-310 is in compliance with the essential requirements
and other relevant provisions of Directive. The device can be freely operated in the EU. The
Declaration of Conformity can be found at http://www.emos.eu/download.
CZ | Zkoušečka napětí
Zkoušečka VT-310 je určeke dvojpólovému ření velikosti stejnosměrného a stří-
davého napětí od 110 do 400 V s frekvencí 0–60 Hz, k určení fázového vodiče, pořadí
fází trojfázové soustavy s nulovým vodičem a určení polarity stejnosměrného napětí.
Zkoušečka vyhovuje normě EN 61243-3:2014, v rozsahu 110–400 V/CAT III 400 V, se
stupněm ochrany IP54.


Product specificaties

Merk: EMOS
Categorie: Niet gecategoriseerd
Model: M0014A

Heb je hulp nodig?

Als je hulp nodig hebt met EMOS M0014A stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd EMOS

EMOS

EMOS DCAZ10 Handleiding

16 November 2024
EMOS

EMOS ZV1161 Handleiding

14 November 2024
EMOS

EMOS DCTW14 Handleiding

24 September 2024

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd