Emko EDA-3700 Handleiding

Emko Meetapparatuur EDA-3700

Lees hieronder de 📖 handleiding in het Nederlandse voor Emko EDA-3700 (3 pagina's) in de categorie Meetapparatuur. Deze handleiding was nuttig voor 62 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/3
2.2 Panel Cut-Out
2. General Description
2.1 Front View and Dimensions of EDA-3700 AC/DC Ammeter
76 mm / 3 inch
Mounting Clamp
Panel Surface
(maximum thickness 15 mm / 0.59 inch)
Front Panel
IP65 protection
NEMA 4X
EDA-3700 77x35 DIN SIZE
2
3 41615
13 14
1.2 Installation
1.4 Maintenance
Manufacturer Company Name:
Emko Elektronik A.S. DOSAB Karanfil Sk.No:6 16369 BURSA/TURKEY
Repair and maintenance service information:
Emko Elektronik Sanayi ve Ticaret A. .Ş
Demirta Organize Sanayi Bölgesi Karanfil Sk.No:6 16369 BURSA/TURKEYş
6 mm / 0.24 inch
34,5 mm / 1.36 inch
65 mm / 2.56 inch
Maksimum 15 mm / 0.59 inch
110 mm / 4.33 inch (min)
71 mm / 2.79 inch
29 mm / 1.14 inch
50 mm / 1.97 inch (min)
P
EDA-3700
EDA-3700
x 35 DIN Size
Programmable AC / DC Ammeter
AC / DC Ammeter
Operating Temperature : 0 to 50 °C
Max. Operating Humidity : %90 Rh (Yo unla ma olmaks z n)ğ ş ı ı
: Up to 2000 m.
Forbidden Conditions:
Corrosive atmosphere
Explosive atmosphere
Homeapplications (The unit is only for industrial applications)
EDA-3700
Alarm Output
Current and mV input
1. Environmental Ratings
Power Supply
Input
Sensor Input
230VV ( %15) 50/60Hz±
ON/OFF Operation
Standard
- 4 digits display
- Easily changeable from front panel
- 5A or 60 mV AC, DC, AC/DC input
- Programmable scale from 5A to 9999A
- Alarm parameters
- Password protection for programming mode
- Remote access,data collecting and controlling with Modbus RTU
- AC, DC or True RMS measuring feature
- Having CE mark according to European Norms
A visual inspection of this product for possible damage occurred during shipment is
recommended before installation. It is your responsibility to ensure that qualified mechanical
and electrical technicians install this product.
If there is danger of serious accident resulting from a failure or defect in this unit, power off
the system and separate the electrical connection of the device from the system.
The unit is normally supplied without a power supply switch or a fuse. Use power switch and
fuse as required.
Be sure to use the rated power supply voltage to protect the unit against damage and to
prevent failure.
Keep the power off until all of the wiring is completed so that electric shock and trouble with
the unit can be prevented.
Never attempt to disassemble, modify or repair this unit. Tampering with the unit may results
in malfunction, electric shock or fire.
Do not use the unit in combustible or explosive gaseous atmospheres.
During putting equipment in hole on the metal panel while mechanical installation some metal
burrs can cause injury on hands, you must be careful.
Montage of the product on a system must be done with it’s fixing clamps. Do not do the
montage of the device with inappropriate fixing clamp. Be sure that device will not fall while
doing the montage.
It is your responsibility if this equipment is used in a manner not specified in this instruction
manual.
Repairs should only be performed by trained and specialized personnel. Cut power to the
device before accessing internal parts.
Do not clean the case with hydrocarbon-based solvents (Petrol, Trichlorethylene etc.). Use
of these solvents can reduce the mechanical reliability of the device. Use a cloth dampened
in ethyl alcohol or water to clean the external plastic case.
P
EDA-3700
AC
DC
AC
DC
Housing & Mounting :76mm x 34.5mm x 71mm plastic housing for panel
Mounting. Panel cut-out is 71x29mm.
Protection Class : NEMA 4X(IP65 at front, IP20 at rear).
Weight : Approximately 0.20 Kg.
Environmental Ratings : Standard, indoor at an altitude of less than 2000 meters
with none condensing humidity.
Storage / Operating Humidity : 90 % max. (None condensing)
Installation : Fixed installation
Overvoltage Category : II.
Pollution Degree : II,office or workplace, none conductive pollution
Operating Conditions : Continuous
: ON / OFF
Display : 14 mm Red 4 digits LED Display
LED : AC(Red), DC(Red),Alarm (Red),Program(Green)
7. Speci cations
Device Type :AC/DC Ammeter
Relay Outputs : 8A@250V for Resistive load (Alarm output)V
(Electrical life : 100.000 switching at full load)
Supply Voltage and Power : 230V ( %15) 50/60Hz - 1.5VA,
V ( %15) 50/60Hz - 1.5VA,
V ( %15) 50/60Hz - 1.5VA, V 1.5W
±
±
±
115
24 10...30V
Sampling Cycle : According to parameter value
Storage / Operating Temperature
Accuracy : %1±
Scale : AC and RMS 0 - 9999
DC (-1999) - 9999
A BC D E FG HI /
/
U V W Z/
/ 0 0 0
Alarm Output
Supply VoltageA
EDA-3700
4115V ( %15) 50/60Hz - 1.5VA±
5 230V ( %15) 50/60Hz - 1.5VA±
00 00
810 - 30 V
(77x35 DIN Size)
Your Technology Partner
Thank you very much for your preference to
use Emko Elektronik products, please visit our
web page to download detailed user manual.
www.emkoelektronik.com.tr
324VVV ( %15) 50/60Hz - 1.5VA±
Before commissioning the device, parameters must be set in accordance with desired use.
Incomplete or incorrect configurations can cause dangerous situations.
All order information of EDA-3700 AC/DC Ammetre are given on the table at left. User may form
appropriate device configuration from information and codes that at the table and convert it to the
ordering codes. Firstly, supply voltage then other specifications must be determined. Please fill the order
code blanks according to your needs.
Please contact us, if your needs are out of the standards.
E
90
1
0
None
CommunicationD
1
0
None
RS485
0
Input impedance : 20mΩ
1K2Ω
Approvals ,
:
Relay Output 8A@250V at resistive load ,NO+NC)
1.1 General Specifications
1.3 Warranty
1.5 Manufacturer Company
Instruction Manual. ENG EDA-3700 01 V00 09/17
Phone:+90 224 261 19 00
Fax :+90 224 261 19 12
Phone:+90 224 261 19 00
Fax :+90 224 261 19 12
EMKO Elektronik warrants that the equipment delivered is free from defects in material and
workmanship. This warranty is provided for a period of two years. The warranty period starts
from the delivery date. This warranty is in force if duty and responsibilities which are
determined in warranty document and instruction manual performs by the customer
completely.
Altitude
Control Form
: -30 °C to +80 °C / -20 °C to + 70 °C
V
V
V
V
V
V
V
V
8. Ordering Information
115V ( %15)50/60Hz,V
24V ( %15)50/60Hz,V
±
±
Optional Supply Voltage
10 - 30V Z
V
Z
W
Vac
Vdc
Vdc or Vac can be applied
4.Front Panel Definition and Accessing to the Menus
BUTTON DEFINITIONS1.
1. Increment Button :
** It is used to increase the value in the Programming mode.
2. Decrement Button :
** It is used to decrease the value in the Programming mode.
** To access the programming screen; in the main operation screen, press this button for 5
seconds.
LED DEFINITIONS
5. Alarm Output Led :
** The led is active when the measurement method AC is selected.
** Blinks in programming mode .
5 6 9 10
121187
1-Before mounting the device in your panel,
make sure that the cut-out is of the right size.
2-Insert the device through the cut-out. If the
mounting clamps are on the unit, put out them
before inserting the unit to the panel.
3- Insert the mounting clamps to the fixing sockets
that located left and right sides of device and make
the unit completely immobile within the panel
Before starting to remove the unit from
panel, power off the unit and the related
system.
2.3 Panel Mounting
2.4 Removing from the Panel
3. PROKEY ANAHTARININ KULLANIMI
3
2
1
5 6 7 8
1
2
3
4
P
EDA-3700
3
1
3
2
1-Pull mounting clamps from left and right fixing
sockets.
2-Pull the unit through the front side of the panel
** The led is active when the alarm relay is active.
3.1 Supply Voltage Input Connection of the Device
Power Supply Connection
EXTERNAL
Note-1
Supply
Switch
SupplyVoltage
4 5
L N
230V ( %15) 50/60Hz ,
115V ( %15) 50/60Hz,
24V ( %15) 50/60Hz,
±
±
±
10...30 V - 1.5 W
Must be determined in order.
Make sure that the power supply voltage is the same
indicated on the instrument.
Switch on the power supply only after that all the
electrical connections have been completed.
Supply voltage range must be determined in order.
While installing the unit, supply voltage range must be
controlledand appropriate supply voltage must be
applied to the unit.
There is no power supply switch on the device. So a power
supply switch must be added to the supply voltage input.
Power switch must be two poled for seperating phase and
neutral, On/Off condition of power supply switch is very
important in electrical connection.
3.2 Device Label and Connection Diagram
230VVCONNECTION
P/N:EDA-3700.5.09.1.1/00.00/0.0.0.0
230 V ± 15%
50/60Hz - 1.5VA
7 8
9 10 11 12
+
Max.
/ /
Max. 60mV
/ /
+
- -
5A
OUTPUT
8A@250V
BACOM.
230 V ± 15%
50/60Hz - 1.5VA
7 8
9 10 11 12
+
Max.
/ /
Max. 60mV
/ /
+
- -
5A
OUTPUT
8A@250V
BACOM.
AC
DC
AC
DC
EDA-37 00
AC
DC
EDA-37 00
EDA-37 00
P
AC
DC
3. Program Button:
4. Enter Button:
It is used to saving value in the programming screen.
6. AC Measurement Led :
7. DC Measurement Led:
** The led is active when the measurement method DC is selected.
8. Program led:
** If AC / DC is selected, AC and DC will be active at the same time.
3. Electrical Wiring Diagram
21 5 7 8
P/N : EDA-3700
3
Relay
L
N
Supply Voltage Input
230V ( %15) 50/60Hz±V
115V ( %15) 50/60Hz±V
24V ( %15) 50/60Hz±V
24V ( %15) 50/60Hz±W
1094 6 1112
Ak mı
AC
DC
AC/DC
+
-
+
-
mV
AC
DC
AC/DC
COM.
A
B
5. Programming Mode Parameter List
Measurement Metod Parameter( Default = AC/dC)
Current conversion ratio parameter (Default = 5)
It can be set from 5 to 9999. If this parameter is changed, these parameters
Can be set to AC, DC, AC/DC.
Measurement method is AC.
Measurement method is DC.
Measurement method is AC/DC.
Sampling Time Parameter ( Default = 4)
Sampling time : 250ms
Sampling time : 500ms
Sampling time : 750ms
Sampling time: 1sn
Sampling time is set with this parameter. It can be adjusted from 0 to 3.
Up Limit Alarm Set Parameter( Default = 5.000)
Up Limit Alarm Hysteresis Parameter ( Default = 0.100)
/ 5
Up Limit Alarm On Delay Time Parameter ( Default = 0)
It can be adjusted from 0 to 999.
Low Limit Alarm Set Parameter( Default = 0.000)
It can be adjusted between lower scale and upper scale that is specified with
parameter. This parameter can't be higher than
Low Limit Alarm Hysteresis Parameter( Default = 0.100)
Low Limit Alarm On Delay Time Parameter ( Default = 0)
Decimal Point Position Parameter ( Default = 0.000 )
Decimal Point Position is determined by this parameter. It can be adjusted from 0 to 3.
Up Limit Alarm Delay Parameter After Power On
It can set from 0 to 999 seconds.
Device communication address parameter (1 to 247).
Programming SectionAccessing Password ( Default = 0 )
It is used for accessing to the programming section. It can be adjusted from 0 to 9999.
If it is selected 0, password will not be asked.
A
-A
0T/2 T 3T/2 2T
DCAC
AC/DC(rms)
3
1
A3
1
A 0.000
A
-A
0T/2 T3T/2 2T
A A 0.000
A
0T/2 T 3T/2 2T
2
1
A2
1
A2
1
A
A
0d d
T 2T
T
d
AAT
d
T
d
-
2
2
T
d
A
0
A
-A
T/2 T 3T/2 2T
2
1
A2
1
A0.000
0
A
T/2 T 3T/2 2T
2
1
A
π
2
A0.308A
0
A
T/2 T 3T/2
2
1
A 0.386A
π
1
A
5.1 Operations Graphics of EDA-3700 AC/DC Ammetre 5.2 EDA-3700 AC/dC Ampermetre Cihaz Alarm Çal ma Grafikleriı ış
Input
cUH
cUH - HSU
cUL + HSL
cUL
dLU dLL dLLdLU
Low Limit Alarm On Delay Time Parameter 1
Low Limit Alarm On Delay Time Parameter 1
Alarm Set Value Low Limit Parameter
Alarm Set Value Up Limit Parameter
Press enter button for saving the
parameter.
Press increment button for accessing to the
next parameter, press decrement button for
accessing to the previous parameter
When PROG button is pressed for 5
seconds, “P” led starts to blink. If
programming mode entering
password is different from 0,
programming mode entering screen
will be observed.
Main Operation Screen
Programming Screen
Change the value with increment
and decrement buttons.
Current Conversion Ratio
Parameter Value
Press enter button for accessing to the parameter
value. Press increment button for accessing to the
next parameter, press decrement button for
accessing to the previous parameter.
Press ENTER button for
accessing to the
password entering
screen.
Enter programming mode accessing password
with increment and decrement buttons.
Note-2:If programming mode accessing password is 0,only three parameters
area ccessible,and the parameter values can be changed.
Press ENTER button for
entering the password.
Current Conversion Ratio
Parameter Value
If no operation is performed in programming mode for 20 seconds, device turns to main
ioperation screen automatically..
i
Measurement Method Parameter
5. 3 Entering to the Programming Mode, Changing and Saving Parameters
OF PS
EDA-3700
SP
EDA-3700
F S P
EDA-3700
OF S P
EDA-3700
OFSP
EDA-3700
O
FSP
EDA-3700
O
F S P
EDA-3700
F S P
EDA-3700
Password Entering Screen
Note1: If programming
mode accessing password
is 0, Current conversion
ratio parameter is
observed instead of
programming screen
P
P
P
P P
P
P
P
6. Monitoring of Software Revision of EDA-3700 Devices
OF PS
EDA-3700
P
AC
DC
6.1 Error Messages on EDA-3700 AC / DC Ammeter
O
F PS
EDA-3700
P
AC
DC
O
F PS
EDA-3700
P
AC
DC
When the measured current value exceeds the upper scale,
"nnnn" and "9999" are alternately displayed on the screen.
When the measured current value exceeds the subscale,
"uuuu" and "-1999" are alternately displayed on the screen.
When the AC / DC ammeter is energized, firstly the revision number of the software is displayed to
the user.
Software revision number
'' rU " Revision letter
, , , ) must be updated again.
NC
NO
C
InputInput
Must be determined in order.
Output
DIAGRAM
External fuse that on power supply inputs must be on
phase connection.
External fuse that on power supply inputs must be on
(+) connection.
External fuse is recommended.Note-1:
FUSE
1A T
(Slave ID Parameter
It can set from 0 to 999 seconds.
No point “0”
Between first and second digits “0.0”
Between first and second digits “0.00”
Between first and second digits “0.000”
This parameter can not be greater than
It can be adjusted from 0 to .
/ 5
This parameter can not be greater than
It can be adjusted from 0 to .
Password Entering Screen
Password Entering Screen
It can be adjusted between minimum and maximum scale that is specified with
parameter. This parameter can't be lower than
(This output is available on alarm
output devices)
V
Z
W
V
Z
W
V
V
V
V


Product specificaties

Merk: Emko
Categorie: Meetapparatuur
Model: EDA-3700

Heb je hulp nodig?