EN AIR CONDITIONER
FR CLIMATISEUR
IT CONDIZIONATORE
NL AIR CONDITIONER
DE KLIMAGERÄT
PL KLIMATYZACJA
CZ KLIMATIZAČNÍ ZAŘÍZENÍ
EXP09CKEWI
EXP11CKEWI
USER MANUAL
MODE D'EMPLOI
MANUALE DELL’UTENTE
GEBRUIKSAANWIJZING
BEDIENUNGSANLEITUNG
INSTRUKCJA OBSŁUGI
UŽIVATELSKÁ PŘÍRUČKA
2
24
46
68
90
112
134

2www.electrolux.com
WE’RE THINKING OF YOU
CUSTOMER CARE AND SERVICE
Thank you for purchasing an Electrolux appliance. You’ve chosen a product that brings with
it decades of professional experience and innovation. Ingenious and stylish, it has been
designed with you in mind. So whenever you use it, you can be safe in the knowledge that
you’ll get great results every time.
Welcome to Electrolux.
Always use original spare parts.
When contacting our Authorised Service Centre, ensure that you have the following data
available: Model, PNC, Serial Number.
The information can be found on the rating plate.
Subject to change without notice.
Warning / Caution-Safety information.
General information and tips.
Environmental information.
Get usage advice, brochures, trouble shooter, service information:
www.electrolux.com/webselfservice
Visit our website to:
Register your product for better service:
www.registerelectrolux.com
Buy Accessories, Consumables and Original spare parts for your appliance:
www.electrolux.com/shop
CONTENTS
1. SAFETY INFORMATION ������������������������������������������������������������������������������������� 3
2. 6SAFETY INSTRUCTION �������������������������������������������������������������������������������������
3. 10UNIT DESCRIPTION �����������������������������������������������������������������������������������
4. 10ACCESSORIES INCLUDED ���������������������������������������������������������������������
5. INSTALLATION INSTRUCTIONS ��������������������������������������������������������������������� 11
6. AIR CONDITIONER FEATURES ��������������������������������������������������������������������� 14
7. OPERATING INSTRUCTIONS ��������������������������������������������������������������������� 14
8. CARE & CLEANING ������������������������������������������������������������������������������������������� 20
9. 21TROUBLE SHOOTING �����������������������������������������������������������������������������������
10. ENVIRONMENTAL CONCERNS ��������������������������������������������������������������������� 23

3ENGLISH
1. SAFETY INFORMATION
WARNING!
•This appliance can be used by children aged from 8
years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe way
and understand the hazards involved�
•Children shall not play with the appliance�
•If the supply cord is damaged, it must bereplaced by
the manufacturer, its service agent or similarly qualied
persons in order to avoid a hazard�
CAUTION!
•Contact authorised service technician for repair or
maintenance of this unit�
•Contact the installer for installation of this unit�
•The air conditioner is not intended for use by young
children of inrmed persons without supervision�
•Young children should be supervised to ensure that they
do not play with the air conditioner�
•There are local council rules regarding maximum
allowable noise levels emitted by air conditioners�
•If the power cord is to be replaced, replacement work
shall be performed by authorised personnel only�
•Installation work must be performed in accordance with
the national wiring standards by authorised personnel
only(if applicable)� Incorrect connection can cause
overheating and re�
•Take care not to catch ngers on fan when adjusting
horizontal louvres�
•The fuse is 250V 3�15A�
•Cleaning and user maintenance shall not be made by
children without supervision�Be aware that refrigerants
may not contain an odour�
This manual explains the proper use of your new air
conditioner� Please read this manual carefully before using the
product� This manual should be kept in a safe place for handy
reference�

4www.electrolux.com
1.2 Point to Keep in Mind When Using Your Air Conditioner
CAUTION!
Warnings for use
CAUTION!
Warning for power supply cord
•This power plug must only be plugged into an
appropriate wall socket� Do not use in conjunction with
any extension cords�
•Push the power plug securely into the socket and make
sure it is not loose�
•Do not pull, deform� or modify the power supply cord,
or immerse it in water� Pulling or misuse of the power
supply cord can result in damage to the unit and cause
electrical shock�
•If the supply cord is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualied
•Do not modify any part of this product�
•Do not insert anything into any part of the unit�
•Ensure the power supply used has an appropriate
voltage rating� Only use a 220V - 240V, 50Hz, 10A
mains electricity supply� Use of a power supply with an
improper voltage rating can result in damage to the unit
an possibly re�
•Always use a circuit breaker or fuse with the proper amp
rating� Do not, under any circumstances, use wire, pins
or other objects in place of a proper fuse�
•In the event of any abnormality with the air conditioner
(eg� a burning smell), turn it off immediately and
disconnect the power supply�
1.1 Important notes
1� Do not operate unit without the air lter�
2� Do not operate unit near any heat source or open re�
3� Do not expose the unit to direct sunlight�
4� Always store or move the unit in an upright position�
5� Do not cover the appliance when in operation or
immediately after use�
6� Always drain condensate before storing unit�

5ENGLISH
1.3 Usage cautions
(only for UK)
•This appliance is equipped with a cord that has a earthed
wire connected to an earthed pin� The plug must be plugged
into a socket that is properly installed and earthed� Do not
under any circumstances cut or remove the square earthed
pin from this plug�
•Be sure to turn the unit off and disconnect the power supply
cord before performing any maintenance or cleaning�
•Do not splash or pour water directly onto the unit�Water can
cause electrical shock or equipment damage�
•Drainage should be performed whenever moving the air
conditioner (see page 14)� If any water remains in the tank, it
may spill out while being moved�
•To ensure proper drainage, the drainage hose must have
no kinks and must not be elevated during dehumidicatioin
mode� If not, the drained water may spill out into the room�
•The temperature around the drainage hose must not be
below freezing point when used� Drained water may freeze
inside the hose, causing water inside the unit to overow into
the room�
•Do not block the exhaust air outlet with obstacles� Cooling
Plug
Grounding tab
Plug
Square earthed pin
person in order to avoid a hazard� Use only the manufacturer
specied power cord for replacement�
•This appliance must be earthed� This appliance is equipped
with a cord having an earth wire� The plug must be plugged
into an outlet that is properly installed and earthed�

9ENGLISH
CAUTION!
caution meaning
When the air lter is to be removed, do not
touch the metal parts of the unit
It may cause an injury
Do not clean the air conditioner with water Water may enter the unit and degrade the
insulation� It may cause an electric shock
Ventilate the room well when used
together with a stove, etc�
An oxygen shortage may occur
When the unit is to be cleaned, switch off,
and turn off the circuit breaker
Do not clean unit when power is on as it
may cause re and electric shock, it may
cause an injury
Do not place a pet or house plant where it
will be exposed to direct air ow
This could injure the pet or plant
Do not use for special purposes Do not use this air conditioner to
preserve precision devices, food, pets,
plants, and art objects� It may cause
deterioration of quality, etc�
Stop operation and close the window in
storm or cyclone
Operation with windows opened may
cause wetting of indoor and soaking of
household furniture
Hold the plug by the head of the power
plug when taking it out
It may cause electric shock and damage
Turn off the main power switch when not
using the unit for a long time
It may cause failure of product or re
Do not place obstacles around air-inlets or
inside of air-outlet
It may cause failure of appliance or
accident
Always insert the lters securely� Clean
lter once every two weeks
Operation without lters may cause failure
Do not use strong detergent such as wax
or thinner - use a soft cloth
Appearance may be deteriorated due to
change of product colour or scratching of
its surface
Do not place heavy object on the power
cord and ensure that the cord is not
compressed
There is danger of re or electric shock
Do not drink water drained from air
conditioner
It contains contaminants and could make
you sick
Use caution when unpacking and installing Sharp edges could cause injury
If water enters the unit, turn the unit off
at the power outlet and switch off the
circuit breaker� Isolate supply by taking the
power-plug out and contact a qualied
service technician
It could cause electric shock and damage

10 www.electrolux.com
3
6
7
8
10
11
4 5
9
1
2
3. UNIT DESCRIPTION
• Check all the accessories are included in the package and please refer to the
installation instructions for their usage�
1
2
5
3
9
10
11
8
4
6
7
Remote control
Signal receiver
Carrying handle(both sides)
Room air outlet Bottom drain outlet
Air exhaust
Castor
Control panel
Power cable
Air intake
Continuous drain outlet
4. ACCESSORIES INCLUDED
1
2
3
4
8
5
9
6
10
7
11
PARTS PARTS NAME: QUANTITY:
Window kit connector A
Exhaust connector B
Window sliding kit
Exhaust hose
Foam seal A
Screws
Foam seal B
Safety lock
Remote control
1 pc
1 pc
1 set
1 pc
2 pcs
4 pcs 12�7 screws
2 pcs 19 screws
1 pc
1 pc
1 set
Bolts
Bettery
2 pcs
2 pcs

11ENGLISH
5. INSTALLATION INSTRUCTIONS
5.1 Exhausting hot air
In the Cool Mode the appliance must be
placed close to a window or opening so
that the warm exhaust air can be ducted
outside� First position unit on a at oor
and make sure there’s a minimum of
30mm clearance around the unit, and is
within the vicinity of a single circuit outlet
power source�
1. Extend either side of the hose(Fig�1) and
screw the hose to connector A (Fig�2)�
3. Install the connector B into the unit
(Fig�4)�
3. Afx the connector A into the window
slider kit and seal� (Fig�5&6)
Fig. 4
2. Extend the other side of the hose and
screw it to connector B (Fig� 3)�
Fig.1
Lock
2
Slide onto
1
The hose can be extended from
its original length of 38cm up to
150cm, but it is the best to keep
the length to minimum required�
Also make sure that the hose does
not have any sharp bends or sags�
(Fig� 7)
Fig.7
1. Cut the foam seals A(adhesive type) to
the proper lengths and attach them to
the window and stool�(Fig�8)
5.2 Installation in a double-hung
sash window

12 www.electrolux.com
Fig.10
Cut t his to fit your window
Fig.11
s12.7mm crews
19mm screws or 12.7mm
hex head ca screwp s
Window stool
Window slider tki
Fig.12
Fig.13
F oam seal B
Fig.14
Foam seal A
(adhesive type)
2. Open the window sash and place the
window slider kit on the window stool
(Fig�9)� Attach the window slider kit to
the window stool� Adjust the length of
the window slider kit according to the
width of window� Screw down the two
screws on the window slider kit� See
Fig�9�
1. Cut the foam seals A(adhesive type) to
the proper lengths and attach them to
the window frame� See Fig�14�
4. Drive two 12�7mm screws to secure the
window slider kit to the window sash�
(Fig�11)
5. Secure the window slider kit to the
window stool(Fig�11):
A: For wooden window: Use 19mm
screws for securing�
B: For Vinyl-Clad windows: Use 12�7 hex
head cap screws for securing�
7. Cut the foam seal B to an appropriate
length and seal the open gap between
the top window sash and outer window
sash, as shown in Fig�13�
6. To secure lower sash in place, attach
right angle sash lock with 12�7mm
screw as shown(Fig�12)�
3. Close the window sash securely against
the window slider kit�(Fig�11)
Cut the adjustable window slider kit
if the width of window is less than
67�5 cm (Fig�10)�
It is difcult to lock the windows
with the safety lock for Vinyl-Clad
windows, so you can use lock by
window itself�
Fig.9
screws
Window slider kit
Window stool
67.5cm~123cm
Fig.8
Foam eal s A
(adhesive t )ype
5.2 Installation in a sliding sash
window

14 www.electrolux.com
7. OPERATING INSTRUCTIONS
Some of the following instructions
can only be used by using the
Control Panel�
It is not necessary to use the
drainage hose in the "cool" mode�
Cooling mode
Fan mode
Heating mode (on some models)
In this mode the exhaust adaptor hose
MUST be used�In this mode, there is no need to use the
exhaust hose or drainage hose�
In this mode the exhaust adaptor hose
MUST be used�
In this mode, fan speed cannot be
selected�
7.1 Usage of the Control Panel
1. Press the “mode” button until the Cool
mode indicator is lit�
2. Press the "fan speed" button to
choose the fan speed according to the
illumination of the fan speed indicator�
You can choose the “hi”, “med”, “low”,
or “auto” fan speed setting�
3. Press the “ ” or “ ”button to choose
the temperature you want�
1. Press the "mode" button until the "Heat"
indicator is lit�
2. Press the " " & " " Temp buttons for
desired setting�
3. Connected drain hose� See 7�3
Drainage section�
6. AIR CONDITIONER FEATURES
6.1 CONTROL PANEL
1
23456
cool dry fan autotimer hi med low au l rto te
hold 5s
l setter re
temp imer/t on ff/ofan speedmodetimer
1
25
3
4
6
Displays temperature/time
Power ON/OFF Mode Selection
Fan Speed / Filter Reset
Adjust Temperature or Timer
Timer
Dry mode
Press the “mode” button until the Dry
mode indicator is lit� The screen displays
the room temperature�
At the same time, the “low” fan indicator
lights�
Note: In this mode, fan speed cannot be
selected�

15ENGLISH
1. Press the "mode" button until the Fan
mode indicator is lit�
2. Press the "Fan speed" button to choose
the desired fan speed�
3. The fan will run at the selected speed
and the display will show the room
temperature�
Filter reset
Auto mode
Timer mode
How to delay startup
How to delay shutdown
Always have the exhaust hose attached in
this mode�
When you set the air conditioner in Auto
mode, it will automatically select cooling,
heating (inapplicable for cooling only
models), or fan only operation depending
on what temperature you have selected
and the room temperature� The air
conditioner will control room temperature
automatically round the temperature point
set by you�
Under AUTO mode, you can not select the
fan speed�
1� Press the "mode" button until the "Auto
mode" indicator lights�
After the "Auto mode" is selected the unit
will run automatically according to the
actual room air temperature�
The timer facilitates the user to delay the
unit startup or shutdown�
Plug in the unit, so the unit turns to
standby�
Press the “timer” button, then the Timer
indicator and number of hours on the
screen will ash�
Tap or hold the UP arrow " " or the
DOWN arrow " " to change delay start
timer at 0�5 hour increments up to 10
You can delay shutdown when the unit is
on�
Press the “timer” button, then the Timer
indicator and number of hours on the
screen will ash�
Tap or hold the UP arrow " " or the
DOWN arrow " " to change delay stop
timer at 0�5 hour increments up to 10
hours, then at 1 hour increments up to 24
hours�
After 5 seconds, the Timer indicator and
the display stop ashing, and the display
shows the time remaining until the unit
shuts down�
To cancel the setting, press the “timer”
button again� The timer indicator will
switch off�
This feature is a reminder to clean the Air
Filter (See Care and Cleaning) for more
efcient operation�
The lter indicator will illuminate after 250
hours of operation� To reset after cleaning
the lter, hold the “fan speed” button for 5
seconds, then the “lter” indicator will go
off�
hours, then at 1 hour increments up to 24
hours�
After 5 seconds, the Timer indicator and
the display stop ashing� The control
will count down the time remaining until
startup�
The unit will start up in the mode as
previously set�
To cancel the setting, press the “timer”
button again� The timer indicator will
switch off�

16 www.electrolux.com
User
Max. 5 m
Remote control
Portable AC
TURNING THE UNIT ON
Remove the cover at the back of the
remote control�
Insert the provided batteries correctly(see
the instructions inside the battery
compartment)�
Close up the cover�
To replace the old batteries(which have
been used up)
Battery Installation and Important
Instructions
How to Use the Remote Control
7.2 Remote Control
1
2
5
9
3
7
4
8
6
10
Remote Control screen
Timer on button
Mode button
Fan Speed button
Timer off button
°F/°C button
Sleep button
Swing button
Temp/Timer setting button
On/Off button
with two new R03P “AAA” 1�5V batteries,
repeat the steps above�
If the remote control unit is replaced or
discarded, the batteries must be removed
and disposed of in accordance with
local legislation as they do harm to the
environment�
Do not mix old and new batteries�
Do not mix alkaline, standard (carbon-
zinc) or rechargeable (nickel-cadmium)
batteries�
Do not dispose of batteries in re� Batteries
may explode or leak� If the remote control
is not used for a long time, remove the
batteries from the remote control�
The remote control must be handled with
extreme care� Do not drop it or expose it
to direct sunlight or sources of heat�
This device complies with Part 15 of the
FCC Rules� Operation is subject to the
following two conditions:
(1) This device may not cause harmful
interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation�
Point the remote control at the location
of the signal receiver� The remote control
must be no more than 16 ft(5 meters)
away from the unit (without obstacles
between the remote control and the unit)�

17ENGLISH
Plug in the unit, then press the “on/
off” button (when turned on, the unit
will operate as the last setting before
shutdown�
To switch the unit off, press “on/off” button
again, then remove the plug�
Do NOT switch the unit off by removing
the plug�
Always switch the unit off by pressing the
“on/off” button and wait for few minutes
before removing the plug�
Press the “mode” button until the left side
of LCD screen displays “ ”�
Press the “fan speed” button to choose
the fan speed “Hi”, “Med”, “Low”, and
“Auto”�
Press the “ ” and “ ”button to choose
the temperature you want
Press the “mode” button until the left side
of LCD screen displays “ ”�
At the same time, the “low” fan symbol
appears on the screen�
Note: In this mode, fan speed cannot be
selected�
Press the “mode” button until the left side
of LCD screen displays “ ”�
Press the “ ” and “ ” button to choose
the temperature you want� At the same
time, the “low” fan indicator lights�
Note: In this mode, fan speed cannot be
selected�
Press the “mode” button until the upper
side of LCD screen displays “ auto ”�
Under AUTO mode, you can not select the
fan speed�
Press the “ ” and “ ” button to choose
the temperature you want�
When the unit is in Cool, Heat or auto
mode, you can press the “sleep” button
to make the unit run in Sleep mode� In this
mode, the fan speed will be set as “low”
automatically, which cannot be changed�
In Cool mode the selected temperature
will increase by 1 °C 30 minutes after
Press the “mode” button until the left side
of LCD screen displays “ ”�
In this mode, you can select fan speed
“Hi”, “Med”, “Low” or “Auto” by pressing
the Fan speed button and referring to the
diagram�
Cool mode
Dry mode
Heat mode(For Heat & Cool models only)
AUTO mode
Sleep mode
Fan mode
High Medium Low Auto
Note: In this mode, the air exhaust hose
does not need to be connected�

18 www.electrolux.com
the mode is selected� The temperature
will then increase by another 1 °C after
an additional 30 minutes� This new
temperature will be maintained for 7 hours
before it returns to the originally selected
temperature� This ends the "Sleep" mode
and the unit will shut down automatically�
The "Sleep" mode program can be
cancelled at any time during operation
by pressing the "Sleep", “mode” or “fan
speed” button�
Note: In Fan or Dry mode, Sleep mode
cannot be set�
Press the “swing” button to enable louver
swing function, and the upper side of
screen will display “ ”� The louver on the
top panel will swing up and down�
Press this button again to disable the
louver swing function�
Louver Swing Function
°F/°C function
Timer mode
Press the “°F/°C” button to switch
between degree Fahrenheit and degrees
Celsius� Under Dry/Fan mode, you can not
select °F/°C�
How to delay startup
Plug in the unit, so the unit turns to
standby�
Press the “timer on” button, the screen will
display “ ”and “H”�
Tap or hold the UP arrow " " or the
DOWN arrow " " to change delay start
timer at 0�5 hour increments up to 10
hours, then at 1 hour increments up to 24
hours� After 2 seconds, the setting will be
memorized� The control will count down
the time remaining until startup� The unit
will start up in the mode as previously set�
To cancel the setting, press the “timer on”
button again�

27ANGLAIS
1.3 Précautions à prendre pendant l'utilisation
•Assurez-vous que l'appareil est éteint et débranchez le
cordon d'alimentation électrique avant de procéder à la
maintenance ou le nettoyage.
•N'éclaboussez ou ne versez pas l'eau directement sur
l'appareil. L'eau peut causer un choc électrique ou un
dommage sur l'équipement.
•La vidange doit être réalisée à chaque déplacement du
climatiseur (voir page 14). Si de l'eau reste dans le réservoir,
elle peut se déverser pendant le déplacement.
•Pour assurer la vidange, le tuyau de vidange ne doit pas avoir
des frisottis et ne doit pas être élevé pendant le mode de
déshumidification. Si non, l'eau vidangée peut se déverser
dans la pièce.
•La température autour du tuyau de vidange ne pas être en
dessous du point de congélation pendant l'utilisation. L'eau
vidangée peut se congeler à l'intérieur du tuyau, ce qui peut
causer le déversement de l'eau dans la pièce.
•Si le cordon d'alimentation est endommagé, il doit être remplacé
par le fabricant, son agent de service ou une personne tout aussi
qualifiée pour éviter tout danger. Utilisez uniquement le cordon
d'alimentation spécifié par le fabricant pour le remplacement.
•Cet appareil doit être mis à la terre. Cet appareil est équipé d'un
cordon muni d'un fil de terre. La fiche peut être branchée à
une sortie correctement installée et mise à la terre.
Fiche
Patte de mise
à la masse
•Cet appareil est équipé d'un cordon muni d'un fil de terre
raccordé à une broche mise à la terre. La fiche peut être
branchée dans une prise secteur correctement installée et
mise à la terre. Ne coupez et ne retirez la broche carré mise à
la terre de cette fiche en aucune circonstance.
(uniquement pour
le Royaume-Uni)
Fiche
Broche carrée mise
à la terre

32 www.electrolux.com
3
6
7
8
10
11
4 5
9
1
2
3. DESCRIPTION DE LA MACHINE
1
2
5
3
9
10
11
8
4
6
7
Télécommande
Récepteur de signal
Poignée de transport (deux côtés)
Sortie d'air ambiant Sortie du drain inférieur
Évacuation d'air
Castor
Panneau de commande
Câble d’alimentation
Admission d'air
Sortie de vidange continue
4. ACCESSOIRES INCLUS
PIÈCES NOM DES PIÈCES : QUANTITÉ :
1Connecteur du kit de fenêtre A 1 pc
2Connecteur d'évacuation B 1 pc
3Kit de curseur de fenêtre 1 ensemble
4Tuyau d'évacuation 1 pc
5Vis Vis de 12,7 mm à 4 pcs
Vis de 19 mm à 2 pcs
6Verrou de sécurité 1 pc
7Boulons 2 pcs
8Joint mousse A 2 pcs
9Joint mousse B 1 pc
10 Télécommande 1 ensemble
11 Pile 2 pcs
• Vérifiez tous les accessoires inclus dans le package et reportez-vous aux instructions
d'installation pour leur utilisation.
Product specificaties
Merk: | Electrolux |
Categorie: | Airco |
Model: | EXP09CKEWI |
Kleur van het product: | Wit |
Ingebouwd display: | Ja |
Timer: | Ja |
Gewicht: | 30100 g |
Breedte: | 440 mm |
Diepte: | 325 mm |
Hoogte: | 695 mm |
Geluidsniveau: | 49 dB |
Soort: | Mobiele airconditioner uit één stuk |
Geschikt voor ruimtes tot: | 18 m² |
Koelend medium: | R290 |
Type timer: | Digitaal |
Air conditioner functies: | Cooling, Dehumidifying, Ventilating |
Jaarlijks energieverbruik (koelen): | - kWu |
Energie-efficiëntieklasse (koeling): | A |
Op afstand bedienbaar: | Ja |
Koelcapaciteit in watt (opgegeven): | 2600 W |
Energieverbruik per uur (koeling): | 0.9 kWu |
Energieverbruik per uur (verwarming): | - kWu |
Slaapstand: | Ja |
Ontvochtiging capaciteit: | 1.2 L/u |
Koelcapaciteit (max): | 9000 BTU/h |
Koel capaciteit in watt (max): | - W |
Verwarmingscapaciteit in watt (max): | - W |
Koeling energie efficientie: | 3 |
Verwarmingscapaciteit in watt (opgegeven): | - W |
Type beeldscherm: | LED |
Timerduur (maximum): | 24 uur |
Heb je hulp nodig?
Als je hulp nodig hebt met Electrolux EXP09CKEWI stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Airco Electrolux

29 Juli 2023

22 Juni 2023

11 Juni 2023

10 Juni 2023

1 Juni 2023

25 April 2023

18 April 2023

7 April 2023

1 September 2022

31 Augustus 2022
Handleiding Airco
- Airco Bosch
- Airco Candy
- Airco Samsung
- Airco Delonghi
- Airco Panasonic
- Airco LG
- Airco AEG
- Airco Bauknecht
- Airco BEKO
- Airco Daewoo
- Airco Grundig
- Airco Honeywell
- Airco Inventum
- Airco Karcher
- Airco Medion
- Airco Remeha
- Airco Siemens
- Airco Toshiba
- Airco Unold
- Airco Vaillant
- Airco Whirlpool
- Airco Zanussi
- Airco Zibro
- Airco Adler
- Airco Airwell
- Airco Akai
- Airco Amana
- Airco Amcor
- Airco Apc
- Airco Arcelik
- Airco Argo
- Airco Balay
- Airco Bartscher
- Airco Bavaria
- Airco Be Cool
- Airco Bestron
- Airco Blaupunkt
- Airco Blumfeldt
- Airco Bodin
- Airco Bomann
- Airco Brandt
- Airco D-Let
- Airco Daikin
- Airco Daitsu
- Airco Defy
- Airco Dimplex
- Airco Dometic
- Airco Domo
- Airco Duracraft
- Airco Duux
- Airco Easy Home
- Airco Eco-De
- Airco Eden
- Airco Edgestar
- Airco Edy
- Airco Einhell
- Airco Emerio
- Airco Emerson
- Airco Eurom
- Airco Everglades
- Airco Evolar
- Airco Exquisit
- Airco Fairland
- Airco Ferroli
- Airco Finlux
- Airco Firstline
- Airco Fral
- Airco Frigidaire
- Airco Frilec
- Airco Fronius
- Airco Fuave
- Airco Fuji Electric
- Airco Fujitsu
- Airco G3 Ferrari
- Airco GE
- Airco General Electric
- Airco GlobalTronics
- Airco Gorenje
- Airco Gree
- Airco Gutfels
- Airco H.Koenig
- Airco Haier
- Airco Hisense
- Airco Hitachi
- Airco Holland Electro
- Airco Home Electric
- Airco Hotpoint
- Airco Hotpoint-Ariston
- Airco HQ
- Airco Hyundai
- Airco Iceberg
- Airco Innoliving
- Airco Insignia
- Airco Itho
- Airco Kalorik
- Airco Kelvinator
- Airco Kenmore
- Airco Klarstein
- Airco Koenic
- Airco Kogan
- Airco Korona
- Airco Lanaform
- Airco Lavorwash
- Airco Livington
- Airco Livoo
- Airco Logik
- Airco Magnavox
- Airco Maiko
- Airco Manta
- Airco Master
- Airco Maxicool
- Airco Meaco
- Airco Meireles
- Airco Melissa
- Airco Mesko
- Airco Mestic
- Airco Midea
- Airco Mistral
- Airco Mitsubishi
- Airco Moa
- Airco MPM
- Airco MundoClima
- Airco Nabo
- Airco Nedis
- Airco Philco
- Airco Prem-i-air
- Airco Primo
- Airco Princess
- Airco Profile
- Airco Progress
- Airco Proklima
- Airco Proline
- Airco Protector
- Airco Qlima
- Airco RCA
- Airco REMKO
- Airco Rotel
- Airco Rowenta
- Airco Royal Sovereign
- Airco Russell Hobbs
- Airco Sanyo
- Airco Sauber
- Airco Saunier Duval
- Airco Sencor
- Airco Sencys
- Airco Sharp
- Airco Sigma
- Airco SMC
- Airco Sonnenkonig
- Airco SPT
- Airco Starlyf
- Airco Stirling
- Airco Suntec
- Airco Tarrington House
- Airco Taurus
- Airco TCL
- Airco Team
- Airco Technisat
- Airco Teco
- Airco Tectro
- Airco Telefunken
- Airco Termozeta
- Airco Theben
- Airco Thomson
- Airco Tomado
- Airco Tosot
- Airco Toyotomi
- Airco Trilec
- Airco Tristar
- Airco Tronix
- Airco Trotec
- Airco Truma
- Airco Ufesa
- Airco Vestel
- Airco Vivax
- Airco Waeco
- Airco Westinghouse
- Airco White Knight
- Airco Whynter
- Airco Woods
- Airco Zelmer
- Airco Jocca
- Airco Jocel
- Airco Just Fire
- Airco OK
- Airco Olimpia Splendid
- Airco OneConcept
- Airco Oregon Scientific
- Airco Ozito
- Airco Becken
- Airco Black And Decker
- Airco Camry
- Airco Clatronic
- Airco Concept
- Airco ECG
- Airco Elba
- Airco Essentiel B
- Airco Guzzanti
- Airco Heinner
- Airco Khind
- Airco Orbegozo
- Airco Profilo
- Airco Trisa
- Airco Vox
- Airco Wilfa
- Airco Anslut
- Airco Kunft
- Airco Soler And Palau
- Airco Conrad
- Airco Ansonic
- Airco Aspes
- Airco Comfee
- Airco Corberó
- Airco Danby
- Airco Equator
- Airco Esatto
- Airco IFB
- Airco Infiniton
- Airco Koldfront
- Airco Listo
- Airco Orima
- Airco Svan
- Airco Ardes
- Airco Eldom
- Airco Premium
- Airco Teesa
- Airco Alpatec
- Airco ElectriQ
- Airco Heylo
- Airco HTW
- Airco Prime3
- Airco Avidsen
- Airco SereneLife
- Airco DCG
- Airco Kubo
- Airco Malmbergs
- Airco Challenge
- Airco Calor
- Airco Riffel
- Airco Broan
- Airco RIDGID
- Airco KDK
- Airco Bimar
- Airco Climadiff
- Airco Tripp Lite
- Airco Igenix
- Airco Mabe
- Airco Equation
- Airco Godrej
- Airco Milectric
- Airco Orava
- Airco Simplicity
- Airco Cecotec
- Airco Baxi
- Airco Thermex
- Airco Keystone
- Airco Sanus
- Airco Carrier
- Airco Furrion
- Airco Rinnai
- Airco Sheffield
- Airco Carson
- Airco Artrom
- Airco Carrefour Home
- Airco Céliera
- Airco Commercial Cool
- Airco Coolix
- Airco Hokkaido
- Airco Kibernetik
- Airco Norpole
- Airco Senville
- Airco SHE
- Airco CyberPower
- Airco Perfect Aire
- Airco Ausclimate
- Airco Be Quiet!
- Airco Ariston Thermo
- Airco Element
- Airco Dantherm
- Airco Noveen
- Airco Argoclima
- Airco Heller
- Airco DEXP
- Airco Chigo
- Airco Elgin
- Airco Evapolar
- Airco EcoFlow
- Airco Liebert
- Airco Avalon Bay
- Airco NewAir
- Airco Braemar
- Airco ActronAir
- Airco Klimaire
- Airco Consul
- Airco SEEGER
- Airco LERAN
- Airco Friedrich
- Airco Aerian
- Airco Polocool
- Airco Convair
- Airco Companion
- Airco Volteno
- Airco Arcoaire
- Airco AFINTEK
- Airco Brivis
- Airco MRCOOL
- Airco B-Air
- Airco Monzana
- Airco Kaden
- Airco Geist
- Airco GoldAir
- Airco Sôlt
- Airco Avallon
- Airco Ravanson
- Airco Create
- Airco Columbia Vac
- Airco TURBRO
- Airco BISWIND
- Airco House & Luft
- Airco Daizuki
- Airco Bonaire
- Airco Evapcool
- Airco Vostok
- Airco American Comfort
- Airco Ocean Breeze
- Airco Quirky
- Airco Krone
- Airco KwiKool
- Airco Big Ass Fans
- Airco Arctic King
- Airco Omega Altise
- Airco Climachill
- Airco Heat Controller
- Airco Luma Comfort
- Airco AireMax
- Airco Kaco
- Airco Middle Atlantic
- Airco Goodwe
- Airco Swegon
- Airco InAlto
- Airco JHS
- Airco FREONIC
- Airco ARCTIC WIND
- Airco Electroline
- Airco BLUEPALM
- Airco KuulAire
- Airco Cool-Space
- Airco BOSFOR
- Airco Aconatic
- Airco VänEE
- Airco Mayer
- Airco Yamazen
- Airco Corona
- Airco Symphony
- Airco Soler & Palau
- Airco Universal Blue
Nieuwste handleidingen voor Airco

27 Maart 2025

27 Maart 2025

27 Maart 2025

27 Maart 2025

27 Maart 2025

26 Maart 2025

26 Maart 2025

26 Maart 2025

26 Maart 2025

26 Maart 2025