Eco-Flo EMRY-4788964 Handleiding
Lees hieronder de đź“– handleiding in het Nederlandse voor Eco-Flo EMRY-4788964 (33 pagina's) in de categorie Pomp. Deze handleiding was nuttig voor 38 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/33
Owner’s Manual
Plastic Shallow
Jet Pumps
General Safety . . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . 3-5
Electrical . . . . . . . . . . . . . . . . . . . . . . . . .6
Operation . . . . . . . . . . . . . . . . . . . . . . . . 7
Troubleshooting . . . . . . . . . . . . . . . . . . . 8
Repair Parts . . . . . . . . . . . . . . . . . . . . . . 9
Jet/Tank Assembly . . . . . . . . . . . . . . . . 10
Warranty . . . . . . . . . . . . . . . . . . . . . . . . 11
TABLE OF CONTENTS
Safety: Need safety Info
1. Avoid Pressure Burns/Explosion
2. Avoid Electric Shock
Fill Pump with water: Ensure pump body is lled with water to discharge.
Motor’s Electrical Settings: Set motor to proper voltage,
i.e. voltage supplied to pump – See electrical section
Need Help: Call 1-877-326-3561 for assistance
Important Safety Instructions Safety Labels
Carefully read and follow all safety
instructions in this manual and on pump.
SAVE THESE INSTRUCTIONS – This manual
contains important instructions that should be
followed during installation, operation, and main-
tenance of the product. Save this manual for
future reference.
This is the safety alert symbol. When you
see this symbol on your pump or in this manual,
look for one of the following signal words and be
alert to the potential for personal injury!
Indicates a hazard which, if
not avoided, will result in death or serious injury.
Indicates a hazard which,
if not avoided, could result in death or serious
injury.
Indicates a hazard which, if
not avoided, could result in minor or moderate
injury.
NOTICE indicates practices not related to
personal injury.
Keep safety labels in good condition. Replace
missing or damaged safety labels.
General Safety
Risk of burns. Do not
touch an operating motor. Motors are de-
signed to operate at high temperatures. To
avoid burns when servicing pump, allow it to
cool for 20 minutes after shut-down before
handling.
Do not allow pump or any system compo-
nent to freeze. To do so will void warranty.
Pump water only with this pump.
Periodically inspect pump and system com-
ponents.
Wear safety glasses at all times when work-
ing on pumps.
Risk of explosion. Pump
body may explode if used as a booster
pump.
GENERAL SAFETY
STOP Before you start
For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561
2
DEDICATED SHALLOW WELL PUMP INSTALLATIONS
REPLACING AN OLD PUMP
For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561
Disconnect power to pump before
working on pump or motor.
1. Drain and remove the old pump. Check the old pipe for
scale, lime, rust, etc., and replace it if necessary.
2. Install the pump in the system. Make sure that all pipe
joints in the suction pipe are air-tight as well as water
tight. If the suction pipe can suck air, the pump will not
be able to pull water from the well.
3. Adjust the pump mounting height so that the plumbing
connections do not put a strain on the pump body.
Support the pipe so that the pump body does not take
the weight of piping or ttings.
!
(Figure 1)
Foot Valve
Stainer
Well Casing
Sanitary Well Seal
To Power Box
Suction Pipe
Priming Tee with
Priming Port, Plug
and Pressure
Gauge
To House
Water
System
3
Cased Well Installation (Figure 1)
1. Mount the pump as close to the well as possible.
2. Assemble the foot valve, strainer, and well pipe.
Make sure that the foot valve works freely.
3. Lower the pipe into the well until the strainer is ve
feet above the bottom of the well. It should also be at
least 10 feet below the well’s water level.
4. Install a sanitary well seal.
5. Install a priming tee, priming plug, and pressure gauge
to pump’s discharge port. Connect the pipe from the
well to the pump’s suction port, using the fewest
possible ttings-especially elbows – increase friction
in the pipe. The suction pipe should be at least
as large as the suction port on the pump. Support
the pipe so that there are no dips or sags in the pipe,
so not to strain the pump body, and so that it
slopes slightly upward from the well to the pump
(Note: Not doing so can create air locks preventing
the pump from working properly). Seal the suction
pipe joints with PTFE pipe thread sealant tape or a
PTFE-based pipe joint compound. Joints must be air-
and-water-tight. If the suction pipe can suck air,
the pump cannot pull water from well.
6. See instructions on page 8 for connecting discharge
pipe to tank.
Product specificaties
Merk: | Eco-Flo |
Categorie: | Pomp |
Model: | EMRY-4788964 |
Heb je hulp nodig?
Als je hulp nodig hebt met Eco-Flo EMRY-4788964 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Pomp Eco-Flo
4 Maart 2024
24 Juli 2023
24 Juli 2023
24 Juli 2023
24 Juli 2023
24 Juli 2023
24 Juli 2023
Handleiding Pomp
- Pomp Karcher
- Pomp Nefit
- Pomp Quigg
- Pomp Siemens
- Pomp Vaillant
- Pomp Al-ko
- Pomp Astralpool
- Pomp Bartscher
- Pomp Batavia
- Pomp Bestway
- Pomp Blumfeldt
- Pomp Bulex
- Pomp Danfoss
- Pomp Eheim
- Pomp Einhell
- Pomp Eufab
- Pomp Eurom
- Pomp Ferroli
- Pomp Fluke
- Pomp Fuxtec
- Pomp Gardena
- Pomp Gardenline
- Pomp Generac
- Pomp Germania
- Pomp GRE
- Pomp Gude
- Pomp Hayward
- Pomp Hozelock
- Pomp Husqvarna
- Pomp Hyundai
- Pomp Lavorwash
- Pomp Makita
- Pomp Melinera
- Pomp Metabo
- Pomp Michelin
- Pomp Milwaukee
- Pomp Nibe
- Pomp Parkside
- Pomp Plantiflor
- Pomp POLARIS
- Pomp Powerfix
- Pomp Powerplus
- Pomp Ryobi
- Pomp Sanibroyeur
- Pomp Scheppach
- Pomp Silvercrest
- Pomp Technaxx
- Pomp Toolcraft
- Pomp Trotec
- Pomp Ultimate Speed
- Pomp Velda
- Pomp Vetus
- Pomp Vivaria
- Pomp Vonroc
- Pomp Westfalia
- Pomp WHALE
- Pomp Worx
- Pomp Zipper
- Pomp Zodiac
- Pomp Oase
- Pomp OKAY
- Pomp Osram
- Pomp Ozito
- Pomp Crivit
- Pomp Black And Decker
- Pomp Wetelux
- Pomp Cannondale
- Pomp Fluval
- Pomp Sicce
- Pomp Simpson
- Pomp Aerotec
- Pomp Tacklife
- Pomp Fieldmann
- Pomp Blackburn
- Pomp Lezyne
- Pomp Topeak
- Pomp ZĂ©fal
- Pomp Coleman
- Pomp Outwell
- Pomp Biltema
- Pomp Comet
- Pomp Sun Joe
- Pomp Maruyama
- Pomp Little Giant
- Pomp MSW
- Pomp ESPA
- Pomp Verto
- Pomp Enermax
- Pomp Testo
- Pomp FIAP
- Pomp Neptun
- Pomp Pontec
- Pomp Alpha Tools
- Pomp Hazet
- Pomp Jabsco
- Pomp SKS
- Pomp For_Q
- Pomp Abac
- Pomp Waldbeck
- Pomp Pedrollo
- Pomp Park Tool
- Pomp Panduit
- Pomp DAB
- Pomp Anova
- Pomp Ubbink
- Pomp Esotec
- Pomp Wayne
- Pomp T.I.P.
- Pomp Rule
- Pomp JANDY
- Pomp Elpumps
- Pomp Hollex
- Pomp B-Air
- Pomp Baracuda
- Pomp Lifan
- Pomp Monzana
- Pomp Liberty Pumps
- Pomp BluGarda
- Pomp Grundfos
- Pomp Madimack
- Pomp Sauermann
- Pomp Nowax
- Pomp Zoeller
- Pomp Superior Pump
- Pomp SHURflo
- Pomp EvoHeat
- Pomp Barwig
- Pomp Ribimex
- Pomp Ebara
- Pomp Perlick
- Pomp Basement Watchdog
- Pomp Ergotools Pattfield
- Pomp Zehnder Pumpen
- Pomp SANDPIPER
- Pomp Heissner
- Pomp OSIP
- Pomp Franklin Electric
Nieuwste handleidingen voor Pomp
4 December 2024
4 December 2024
30 November 2024
30 November 2024
23 November 2024
20 November 2024
20 November 2024
20 November 2024
20 November 2024
18 November 2024