Ebm-papst W2S130-BM03-01 Handleiding

Ebm-papst Ventilator W2S130-BM03-01

Lees hieronder de 📖 handleiding in het Nederlandse voor Ebm-papst W2S130-BM03-01 (10 pagina's) in de categorie Ventilator. Deze handleiding was nuttig voor 44 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/10
Operating instructions
W2S130-BM03-01
Translation of the original operating instructions
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2
D-74673 Mulfingen
Phone +49 (0) 7938 81-0
Fax +49 (0) 7938 81-110
info1@de.ebmpapst.com
www.ebmpapst.com
CONTENTS
1. SAFETY REGULATIONS AND NOTES
11. SAFETY REGULATIONS AND NOTES
Please read these operating instructions carefully before starting to work
with the device. Observe the following warnings to prevent malfunctions
or physical damage to both property and people.
These operating instructions are to be regarded as part of this device.
If the device is sold or transferred, the operating instructions must
accompany it.
These operating instructions may be duplicated and forwarded for
information about potential dangers and their prevention.
1.1 Levels of hazard warnings
11.1 Levels of hazard warnings
These operating instructions use the following hazard levels to indicate
potentially hazardous situations and important safety regulations:
DANGER
Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury. Compliance with
the measures is mandatory.
WARNING
Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury. Exercise extreme
caution while working.
CAUTION
Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury or damage of property.
NOTE
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.
1.2 Staff qualification
11.2 Staff qualification
The device may only be transported, unpacked, installed, operated,
maintained and otherwise used by qualified, trained and authorised
technical staff.
Only authorised specialists are permitted to install the device, to carry
out a test run and to perform work on the electrical installation.
1.3 Basic safety rules
11.3 Basic safety rules
Any safety hazards stemming from the device must be re-evaluated
once it is installed in the end device.
The local industrial safety regulations must always be observed when
working on the device.
Keep the workplace clean and tidy. Untidiness in the working area
increases the risk of injury.
Observe the following when working on the unit:
;Do not make any modifications, additions or conversions to the
device without the approval of ebm-papst.
1.4 Electrical voltage
11.4 Electrical voltage
;Check the electrical equipment of the device at regular intervals, refer
to chapter 5.2 Safety test.
;Replace loose connections and defective cables immediately.
DANGER
Electrical load on the device
Risk of electric shock
Stand on a rubber mat if you are working on an electrically
charged device.
21.5 Safety and protective functions
21.6 Mechanical movement
21.7 Emission
21.8 Hot surface
21.9 Transport
21.10 Storage
32. PROPER USE
43. TECHNICAL DATA
43.1 Product drawing
53.2 Nominal data
53.3 Technical features
53.4 Mounting data
53.5 Transport and storage conditions
64. CONNECTION AND START-UP
64.1 Connecting the mechanical system
64.2 Connecting the electrical system
74.3 Connection of the cables
84.4 Connection screen
94.5 Checking the connections
94.6 Switch on device
94.7 Switching off the device
95. MAINTENANCE, MALFUNCTIONS, POSSIBLE
CAUSES AND REMEDIES
105.1 Cleaning
105.2 Safety test
105.3 Disposal
Item no. 10946-5-9970 · ENG · Revision 202174 · Release 2019-01-04 · Page 1 / 10
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions
W2S130-BM03-01
Translation of the original operating instructions
WARNING
Terminals and connections have voltage even with a
unit that is shut off
Electric shock
Wait five minutes after disconnecting the voltage at all poles
before opening the device.
CAUTION
In the event of failure, there is electric voltage at the
rotor and impeller
The rotor and impeller are base insulated.
Do not touch the rotor and impeller once they are installed.
CAUTION
The motor restarts automatically when operating voltage
is applied, e.g. after a power failure.
Danger of injury
Keep out of the danger zone of the device.
When working on the device, switch off the mains
supply voltage and secure the latter from being switched on
again.
Wait until the device stops.
1.5 Safety and protective functions
DANGER
Protective device missing and protective device not
functioning
Without a protective device there is a risk of serious injury, for
instance when reaching into the device during operation.
Operate the device only with a fixed protective device and
guard grille.
The fixed protective device must be able to withstand the
kinetic energy of a fan blade that becomes detached at
maximum speed. There must not be any gaps which it is
possible to reach into with the fingers, for example.
The device is a built-in component. As the operator, you
are responsible for ensuring that the device is secured
adequately.
Stop the device immediately if a protective device is
found to be missing or ineffective.
1.6 Mechanical movement
DANGER
Rotating device
Body parts that come into contact with the rotor and impeller
can be injured.
Secure the device against accidental contact.
Before working on the system/machine, wait until all
parts have come to a standstill.
WARNING
Rotating device
Long hair, dangling items of clothing, jewellery and similar items
can become entangled and be pulled into the device. Risk of
injury.
Do not wear any loose-fitting or dangling clothing or jewellery
while working on rotating parts.
Protect long hair with a cap.
1.7 Emission
WARNING
Depending on the installation and operating conditions,
a sound pressure level greater than 70 dB(A) may arise.
Danger of noise-induced hearing loss
Take appropriate technical safety measures.
Protect operating personnel with appropriate safety
equipment, e.g. hearing protection.
Also observe the requirements of local agencies.
1.8 Hot surface
CAUTION
High temperature at the motor housing
Danger of burn injuries
→ Ensure that sufficient protection against accidental contact is
provided.
1.9 Transport
NOTE
Transport of device
Transport the device in its original packaging only.
Secure the device so that it does not slip, e.g. by using a
clamping strap.
1.10 Storage
;Store the device, partially or fully assembled, in the original
packaging in a clean, dry and weatherproof place free of vibrations.
;Protect the device against environmental effects and dirt until final
installation.
;We recommend storing the device for no longer than one year in
order to guarantee trouble-free operation and longest possible service
life.
;Even devices explicitly intended for outdoor use are to be stored as
described prior to commissioning.
;Maintain the storage temperature, see
chapter 3.5 Transport and storage conditions.
Item no. 10946-5-9970 · ENG · Revision 202174 · Release 2019-01-04 · Page 2 / 10
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions
W2S130-BM03-01
Translation of the original operating instructions
2. PROPER USE
The device is exclusively designed as a built-in device for conveying
air according to its technical data.
Any other usage above and beyond this does not conform with the
intended purpose and constitutes misuse of the device.
Customer equipment must be capable of withstanding the mechanical
and thermal stresses that can arise from this product. This applies for the
entire service life of the equipment in which this product is installed.
Proper use also includes:
Conveying of air at an ambient air pressure of 800 mbar to 1050 mbar.
Using the device in accordance with the permitted ambient
temperature, see chapter 3.5 Transport and storage conditions and
chapter 3.2 Nominal data.
Operating the device with all protective features in place.
Minding the operating instructions.
Improper use
Using the device in the following ways is particularly prohibited and
may cause hazards:
Operating the device with an imbalance, e.g. caused by dirt deposits
or icing.
Resonance mode, operation with heavy vibrations. These also
include vibrations that are transmitted from the customer system to the
fan.
Operation in medical equipment with a life-sustaining or lifesaving
function.
Moving solids content in flow medium.
Painting the device
Connections (e.g. screws) coming loose during operation.
Moving air that contains abrasive particles.
Moving highly corrosive air, e.g. salt spray mist. Exceptions are
devices that are intended for salt spray mist and protected accordingly.
Moving air that contains dust pollution, e.g. suctioning off saw dust.
Operating the device close to flammable materials or components.
Operating the device in an explosive atmosphere.
Using the device as a safety component or for taking on safety-
related functions.
Operation with completely or partially disassembled or modified
protective features.
In addition, all application options that are not listed under proper use.
Item no. 10946-5-9970 · ENG · Revision 202174 · Release 2019-01-04 · Page 3 / 10
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com


Product specificaties

Merk: Ebm-papst
Categorie: Ventilator
Model: W2S130-BM03-01

Heb je hulp nodig?

Als je hulp nodig hebt met Ebm-papst W2S130-BM03-01 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Ventilator Ebm-papst

Handleiding Ventilator

Nieuwste handleidingen voor Ventilator