INSTALLATION
RCI VR166/VR166LMKM
SURFACE MOUNTED VERTICAL ROD STRIKE
© 2018 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: sales_RCI@dormakaba.comISVR166 R12-18TG
Fail Locked = Fail Secure = FL AC = Alternating Current DC = Direct Current
Intermittent Duty = Energized less than 1 minute with 1:5 duty ratio
Continuous Duty = Energized 1 minute or more
Important: Adjust strike as indicated in steps 9 thru 12 to ensure
proper functionality. Ensure the exit device functions as intended for
life safety concerns by verifying electric strike and exit device compatibility.
Maximum latch projection is essential to obtain full engagement.
This product is Fail Secure only.
The local Authority Having Jurisdiction shall be consulted with regard to the use
of selected panic hardware to ensure emergency exit from the secured area.
Installations of this Vertical Rod strike qualify as “Indoor Use Only”
when not continuously exposed to an outdoor environment.
MODE VOLTAGE CURRENT DUTY OHMSPEAK AMPS
Fail Locked 12V AC Intermittent 0.12 52
Fail Locked 12V DC Continuous 0.21 52
Fail Locked 24V AC Intermittent 0.27 52
Fail Locked 24V DC Continuous 0.10 208
UL 294 Performance Ratings:
Access Control Line Security : Level I
Destructive Attack : Level I
Endurance : Level IV
Standby Power : Level I
Catalog Specifications
Wiring Instructions
Use 12VDC wire harness for 12VDC or 12-24VAC input power.
Use 24VDC wire harness for 24VDC input power only.
Attach the red wire to (+) positive of the power supply.
Attach the black wire to the (-) negative of the power supply.
If using AC power, polarity is not observed.
Note: overheated or burnt coils caused by incorrect input voltage/wire harness
combinations will not be covered under warranty.
Electrical Latch & Keeper Monitor Specifications:
• SPDT switch, 0.1A 24VDC resistive load for LM latch monitor
• SPDT switch, 1A 12VDC resistive load for KM keeper monitor
Note: Contacts identified on the harness sleeve are indicated with the keeper in a closed
and locked condition, with no latch present
Horizontal
adjustment
mounting holes
Fig. 1
Lock down clamp
© 2018 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: sales_RCI@dormakaba.com
Frame Prep Detail
1. Close the door and mark the center line of the surface mount latch from door on to the top of the frame.
2. Fold the TVR166 template at the line specified. The folded part is always placed on the door side of frame.
3. Place the template so that the center line previously marked on top of the frame lines up with center line on the
template.
4. If centerlines don’t line up, make sure to horizontally adjust the template so that the latch (on the door) is placed
inside of the box specified on the template.
5. Open the door and carefully tape the template to the frame.
6. Center punch the two 1/4-20 holes on the template. Then drill and tap the 1/4-20 indicators marked.
7. With proper tools mark and cutout the parameters of the cutting lines on the template. Refer to Frame prep details
below. (Fig. 2)
8. Install the VR166 using either one or both Lock down clamps depending on how much room you have from the
vertical side of the frame. Do not fully tighten them yet.
9. Inspect the engagement between the latch and the keeper of lock by opening
and closing the door.
10. The strike can be horizontally adjusted towards or away from the door using
the slotted mounting holes on the faceplate. See Fig. 1.
11. For adjustment in height of the lock please use the 2mm shim provided.
12. Once everything has been adjusted, secure the strike down with either one or both Lock down clamps using
the 1/4-20 screws provided.
Mounting Instructions
(85.5mm)
3-3/8"
(8.0mm)
5/16"
(63.0mm)
2-1/2"
(46.0mm)
1-13/16"
(33.0mm)
1-1/16"
(11.0mm)
7/16"
(23.0mm)
15/16"
C
L
THIS IS A NON-HANDED STRIKE,
TOP RIGHT CORNER HAS BEEN
SHOWN ONLY AS A REFERENCE
DOOR CLOSES AND RESTS
ON THIS FACE. THIS IS THE PULL
SIDE OF THE DOOR/OUTSIDE AND
NEEDS CREDENTIALS/FOB TO GET IN
NOTE: Ensure a 1/16" (1.5mm) clearance between latch and the VR166 keeper is
maintained. Failing to do so will preload the strike, which will not allow the strike
to release the door when energized.
1/16”
(1.5mm)
Fig. 2
Dimensions


Product specificaties

Merk: Dormakaba
Categorie: Niet gecategoriseerd
Model: RCI VR166

Heb je hulp nodig?

Als je hulp nodig hebt met Dormakaba RCI VR166 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Dormakaba

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd