INSTALLATION
RCI 8360
MiniMag® MORTISE ELECTROMAGNETIC LOCK
© 2019 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: sales_RCI@dormakaba.com
1. Hold lock against frame at desired level. Mark the locks horizontal
centerline on the frame and transfer that mark to the door.
2. Determine the vertical centerline of the door thickness and mark
this on both the door and the frame.
3. Using these centerline references, cut out the lock mortise in
the frame as illustrated.
4. Temporarily fasten the two mounting tabs under the lock
flanges. Insert the lock assembly into the frame cavity until the
tabs are resting on top. Mark the location of the tab mounting
holes.
5. Drill and countersink these four holes to accept the 3/16” screws
provided.
6. Remove tabs from lock. Mount the tabs inside the frame.
7. Set voltage dipswitches as follows:
12VDC operation = 1 and 2 are On / 3 is Off
24VDC operation = 1 and 2 are Off / 3 is On (factory setting)
Connect the positive (+) power lead to the red and the negative
(-) lead to the black wire.
Connecting wire should be of sufficient gauge for the lock being
installed and the distance being run. See table on page 3 for
current draw specifications.
8. RLS (Remote Lock Status)
This feature can detect the quality of the locking bond between
the surface of the magnet and the armature plate. The
sensitivity of this feature is such that a foreign object with a
thickness of .007” (.18mm) is sufficient to allow the sensor to
detect a problem.
Due to the sensitivity of this feature and the necessity to
maintain a reliable locking surface, these surfaces must be kept
free of contaminating materials. Both the lock surface and the
armature plate must be cleaned periodically with a non-abrasive
cleanser. Proper alignment of the armature plate and magnet is
required to ensure proper function of sensor.
The 3 RLS lead wires at the lock corner are: Red = Normally
Closed, Black = Common, Green = Normally Open with the
door open / unlocked.
IS8360 PCN18041
R09-19GR-1
Instructions
Pre-Installation Instructions
1. This product must be installed according to all applicable
building and life safety codes.
2. Due to the variety of mounting configurations available with this
product, a survey and assessment of the physical area in which
the product will be installed must be performed.
3. The door frame must be inspected and deemed structurally
sound prior to installation of the electromagnetic lock. The
structural integrity of the mounting surfaces must be strong
enough to meet or exceed the holding force of the product.
4. The product must be protected from potential damage due to
intruders or tampering.
5. The product should be installed in a location that will not hinder
or create a potential safety hazard to authorized personnel
accessing the protected area.
6. Because electromagnetic locks are used in a variety of
applications and different door frame configurations, an
experienced installer with knowledge of this product must make
a determination of the optimal mounting method for this specific
application.
7. Do not install this product on the exterior of buildings.
8. Do not use as a doorstop. This will void warranty.
9. Installation of this product should be done by an experienced
installer with knowledge of this product.
NOTE: It is highly recommended that thread locking compound be
applied to all screws during installation to reduce chance of screws
loosening over extended time.
WARNING: Improper installation, maintenance, inspection or
usage of the product or any related accessories or parts may
cause the electromagnetic lock, armature plate and associated
hardware to disengage and fall, causing serious bodily injury
and property damage. dormakaba Canada Inc .and/or dormakaba
USA Inc. will not be liable to the installer, purchaser, end user
or anyone else for damage or injury to person or property due
to improper installation, care, storage, handling, maintenance,
inspection, abuse, misuse or act of God or nature involving this
product or any related accessories or parts.
PLEASE DELIVER ALL INSTALLATION INSTRUCTIONS TO
THE END-USER UPON COMPLETION OF THE INSTALLATION.
Instructions Cont’d
IMPORTANT: The RLS contacts are rated at a maximum of
0.20 Amps. Greater current will cause damage to the
sensor and will void warranty.
9. Secure lock on tabs in mortise cavity, carefully applying thread
locking compound to the hardware provided.
10. Using centerline references on the door and illustration provided,
drill the four “U” clamp mounting holes and cut out the armature
mortise.
11. Position the “U” clamp inside door as shown. Insert the two pan
head sex nuts from the outside of the door and through the “U”
clamp. Insert the two button head hex bolts from the inside of the
door and secure into the sex nuts.
12. Position bolt with rubber head through armature plate. Add 3
washers (steel - rubber - steel) onto threads. Carefully apply
thread-locking compound to exposed thread and mount onto the
“U” clamp.
NOTE: Do not over tighten. The armature plate must be allowed
to pivot on the mounting bolt to allow proper alignment with the
magnet surface. If the plate is not aligned with the magnet surface,
the lock may lose holding force or not lock at all.
The head of the armature mounting bolt ships with a rubber washer
affixed to it. This washer should project slightly beyond the surface
of the armature plate. This is to allow the washer to expand when
power is removed and break the air vacuum between the plate
and the magnet surface. If this washer is removed or trimmed, the
lock will appear to have some holding force even when power is
removed.
13. With a release device already installed, energize circuit and close
door gently. If magnet does not secure, verify that armature plate
is making contact with face of magnetic block. If necessary, install
additional steel washers behind armature plate to move armature
plate closer to block face and retest.
Inspection and Maintenance
This product and all related accessories or parts must be inspected
and maintained on a Contacting surfaces of quarterly basis.
the electromagnetic lock and armature plate must be kept free of
contaminating materials. Surfaces must be cleaned periodically with a
non-abrasive cleaner.
All mounting fasteners must be inspected on a . When quarterly basis
properly installed, the ends of the armature plate allow a slight movement
but the plate will feel secure when grasped at the bolt. There should be
no movement to the mounting bracket or housing of the electromagnetic
lock.
For added safety, thread locking compound has been provided for the
armature plate bolt and the four electromagnetic lock mounting screws.
WARNING: Improper installation, maintenance, inspection or usage
of the product or any related accessories or parts may cause the
electromagnetic lock, armature plate and associated hardware
to disengage and fall, causing serious bodily injury and property
damage.
PLEASE DELIVER ALL INSTALLATION INSTRUCTIONS TO THE
END-USER UPON COMPLETION OF THE INSTALLATION.
NOTE: All RCI brand electromagnetic locks must be powered with filtered and regulated DC power supplies. dormakaba offers a full line of power
supplies and switching devices that are suitable for use with the 8300 Series locks.
2
© 2019 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: sales_RCI@dormakaba.com
* Interior and exterior drill sizes are different.
NOTE: Specifications are subject to change without notice.
Voltage Current
12VDC 0.50A
24VDC 0.25A
Frame Door
A B E F G H I (Interior) * J (Exterior) *
Inches
Fractional 1-9/16 9 1-9/16 7-5/16 1-7/32 9/16 11/32 1/2
Inches
Decimal 1.57 9.0 1.56 7.32 1.22 0.55 0.34 0.50
Metric
(mm) 40.0 229.0 39.0 186.0 31.0 14.0 8.5 13.0
8360
Electromagnetic
Lock
Mounting
Tab
Frame
Extrusion
AB
Extertior
Side
Interior
Side
Shock absorbin g
rubber washe r
Metal
washers
C
L
C
L
cut
out
cut
out
F
C
L
C
L
G
H
H
J *
C
L
C
L
G
H
H
I *
E
"U" Clamp
Do not over tighten
preventing movement.
Exterior side
door drilling
Interior side
door drilling
Frame
Sliding Door
Frame
Sliding Door
3


Product specificaties

Merk: Dormakaba
Categorie: Niet gecategoriseerd
Model: RCI 8360

Heb je hulp nodig?

Als je hulp nodig hebt met Dormakaba RCI 8360 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Dormakaba

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd