INSTALLATION
RCI 8310 / 8320
ELECTROMAGNETIC LOCKS
© 2020 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: sales_RCI@dormakaba.com
IS8310-20-V1-2
PCN19025
R07-20GR-1
1. Mount the electromagnetic lock to the door frame as outlined on
the installation template included with the product.
NOTE: During installation of the armature plate to the door it
is essential that the armature plate remains movable. The
armature plate must be allowed to pivot on the center-mounting
bolt to allow proper alignment with the magnet surface. If the
plate is not aligned with the magnet surface, the lock may lose
holding force or not lock at all .
The head of the armature mounting bolt ships with a rubber
washer affixed to it. This washer should project slightly beyond
the surface of the armature plate. This is to allow the washer to
expand when power is removed and break the air vacuum
between the plate and the magnet surface. If this washer is
removed or trimmed the lock will appear to have some holding
force even when power is removed.
For added safety, thread locking compound has been provided for
the armature plate bolt and the four captive electromagnetic lock
mounting screws.
WARNING: Improper installation, maintenance, inspection or usage
of the product or any related accessories or parts may cause the
electromagnetic lock, armature plate and associated hardware
to disengage and fall, causing serious bodily injury and property
damage. dormakaba Canada Inc. and/or dormakaba USA Inc. will
not be liable to the installer, purchaser, end user or anyone else for
damage or injury to person or property due to improper installation,
care, storage, handling, maintenance, inspection, abuse, misuse
or act of God or nature involving this product or any related
accessories or parts.
2. Route the power supply connecting wire through the door frame
and into the wire access hole in the top of the magnet housing.
Connecting wire should be of sufficient gauge for the lock being
installed and the distance being run.
Installation Instructions
PLEASE DELIVER ALL INSTALLATION INSTRUCTIONS TO
THE END-USER UPON COMPLETION OF THE INSTALLATION.
Pre-Installation Instructions
1. This product must be installed according to all applicable building
and life safety codes.
2. Due to the variety of mounting configurations available with this
product, a survey and assessment of the physical area in which
the product will be installed must be performed.
3. The door frame must be inspected and deemed structurally sound
prior to installation of the electromagnetic lock. The structural
integrity of the mounting surfaces must be strong enough to meet
or exceed the holding force of the product.
4. The product must be protected from potential damage due to
intruders or tampering.
5. The product should be installed in a location that will not hinder
or create a potential safety hazard to authorized personnel
accessing the protected area.
6. Because electromagnetic locks are used in a variety of applications
and different door frame configurations, an experienced installer
with knowledge of this product must make a determination of the
optimal mounting method for this specific application.
7. The components, hardware, installation instructions and mounting
template included with this product are intended for use on
outswinging doors.
8. Do not install this product on the exterior of buildings.
9. Do not use as a doorstop. This will void warranty.
10. Separate accessories, must be used in the following applications:
Inswinging doors
Narrow head jamb situations or center-hung doors
Wherever there is insufficient space on the door
frame header to mount the lock
Glass or Herculite doors that do not have a door frame
Hollow metal or wood frames where the door stop is
not thick enough to allow the product to be installed
Wherever an obstruction in the door prevents
installation of the armature plate at a proper height
Doors that do not permit the armature plate to be
mounted low enough to meet the magnet surface
Refer to the page 5 & 6 Product Accessories Guide, for further
information. Accessories may impact holding force.
11. Installation of this product should be done by an experienced
installer with knowledge of this product.
NOTE: It is highly recommended that thread locking compound
be applied to all screws during installation to reduce chance of
screws loosening over extended time.
© 2020 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: sales_RCI@dormakaba.com
3. Once wiring has been routed into the lock cavity, connect wire to
terminal blocks as shown in Fig. 1. If optional SCS and/or DSS
features are being used these can also be wired at this time as
shown in Fig. 1.
4. Delayed Relock Feature - Should the built-in delayed relock feature be
required for the installation, a Normally Open Momentary switch such
as an RCI 909 will need to be installed and connected to the two blue
wires from on the circuit board as illustrated in Fig.1. EXIT
The delayed relock feature can be used to momentarily release the
lock and keep it unlocked for a time period from 0 to approximately
35 seconds. The time delay for this feature can be adjusted by
carefully turning the potentiometer (R ) in a counterclockwise W1
direction to increase delay time. Factory setting is zero seconds.
NOTE: On the 8320 double-door model turn bothRCI
potentiometers counterclockwise to increase the relock delay.
If the delayed relock feature is not required the blue wires may be
unplugged from the circuit board @ EXIT.
W1NOTE: If R is not set to zero seconds, the lock will enter
delayed relock mode each time power is applied even if EXIT has
been removed.
2
To Ensure Instant Release - All switching devices must be wired in
between the DC power source and the positive terminal of the lock in
Fig 2.
Switching the negative power supply line will not allow the lock to
release immediately. RCI electromagnetic locks contain MOV’s for
surge suppression and do not require any additional suppression to be
added during installation. The installation of diodes across the lock input
terminals will cause a delay in release.
Fig. 2 Power Connections
SWITCH
+
-
INCORRECT
CORRECT
+
-
SWITCH
FILTERED DC SUPPLY
FILTERED DC SUPPLY
Fig.1 – Lock Wiring
Delayed Relock Adjustmen RW1t
Turn counterclockwise o incr se delay t ea
on 8310 single and both sides of the 8320
double door model.
Lo Power from ack
f ter r lated DCil ed and egu
power su lypp
Opti al SCS nsoron Se
SPDT Out c tacts ratedput on
for maximum 1A @2 DC4V
EXIT EXIT
Two 8 Loc o rel se o ther using310 ks t ea t ge
t lay relock ture.he de ed fea
Blue Wires
Momentary Switch
Bo de 832 Loth si s o an f 0 ck to release together
usi he lay relock f ture.ng t de ed ea
Le circuit boardft Right circui boardt
Optional Del d Relock W ngaye iri
Single lock o release using t
t lay relock ture.he de ed fea
RED - No a y Closedrm ll
GREEN - Normally O npe
BLACK - Common
Opti l DSS r s tch c tacts rat atona eed wi on ed
0.20A@ DC a 0.12A @ 2 DC12V nd 4V
Blue/White
Wires
Blue Wires
Blue/White
Wires
-
+
-
+
EXIT EXIT
Momentary Switch
N/O
N/O
EXIT
Momentary Switch
Blue Wires
Blue/White
Wires
-
+
N/O
Blue Wires
Blue/White
Wires
Blue Wires
Blue/White
Wires
-
+
-
+
EXIT
8310 V1.2 PCB
MAG
Common
No ally Closedrm
No ally Openrm
Comm Gro don un
VDC Input
Both the SCS and DSS options are shown with Door Open
SCS1 LED
*
* NOTE: Models with SCS ship with the low voltage
detection circuit ENABLED (jumper LP_EN on 1 pin only).
To DISABLE low voltage detection, place jumper on both
pins of LP_EN.
© 2020 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: sales_RCI@dormakaba.com
Anti-Tamper Feature - Two screws prevent insertion of an Allen
wrench into the captive mounting screw opening on the bottom of
the lock. Fig. 3 shows their location. One screw also secures the
wiring cavity cover. The mounting plate cannot be separated from
the lock without removing these two screws.
Lock Options
Both of the RCI 8310 and 8320 locks can be equipped with the DSS or SCS
options or both.
SCS (Security Condition Sensor) - This feature can detect the quality of the
locking bond between the surface of the magnet and the armature plate.
Indication is with a local LED as well as remote monitoring through a SPDT
relay output. The sensitivity of this feature is such that a foreign object with
a thickness of .007” (.18mm) is sufficient to allow the sensor to detect a
problem.
Due to the sensitivity of this feature and the necessity to maintain a reliable
locking bond, these surfaces must be kept free of contaminating materials.
Both the lock surface and the armature plate must be cleaned periodically
with a non-abrasive cleanser. Alignment of armature plate and magnet is
required to ensure proper function of sensor.
Low Voltage Detection - Each SCS circuit board also includes a low voltage
detection circuit when shipped from the factory. This feature will cause the
alarm relay and status LED to activate should the lock input voltage drop
below 9VDC. That signals a monitored system or guard station that the
holding force of the lock may have been compromised.
Models with Security Condition Sensor (SCS) have the Low Voltage
Detection circuit when shipped (jumper LP_EN on 1 pin only) ENABLED
To DISABLE Low Voltage Detection, place jumper on both pins of LP_EN.
DSS (Door Status Sensor) - The DSS option monitors the position of the door
upon which the lock is installed. A SPDT reed switch mounted within the lock
cavity eliminates the need for extra sensors to be installed on the door for
notification of security or access control systems. The DSS option comes
with a magnet pre-installed into the lock armature plate for signaling the reed
switch in the housing when the door is closed independent of power to the
lock. Care should be taken during the final testing of the lock to ensure that
the DSS option is operating in the desired manner.
Inspection and Maintenance
This product and all related accessories or parts must be inspected
and maintained on a . Contacting surfaces of the quarterly basis
electromagnetic lock and armature plate must be kept free of contaminating
materials. Surfaces must be cleaned periodically with a non-abrasive cleaner.
All mounting fasteners must be inspected on a . When quarterly basis
properly installed, the ends of the armature plate allow a slight movement
but the plate will feel secure when grasped at the bolt. There should be no
movement to the mounting bracket or housing of the electromagnetic lock.
For added safety, thread locking compound has been provided for the
armature plate bolt and the four captive electromagnetic lock mounting
screws.
WARNING: Improper installation, maintenance, inspection or usage of the
product or any related accessories or parts may cause the electromagnetic
lock, armature plate and associated hardware to disengage and fall,
causing serious bodily injury and property damage.
PLEASE DELIVER ALL INSTALLATION INSTRUCTIONS TO THE
END-USER UPON COMPLETION OF THE INSTALLATION.
Fig. 3 – Lock Mounting
Anti-tamper
feature screw Anti-tamper
feature and
wiring cavity
screw
Captive
mounting screw
Listings
These products have been successfully tested and evaluated by UL in two
separate categories for use in both the United States and Canada.
Auxiliary Lock. The GWXT fire listing qualifies these for use with UL
Classified fire doors maximum 4’ in width and 8’ in height. The
RCI 8310 and 8320 are rated up to and including 1-1/2 hours
(90 minutes).
Special Locking Arrangement Component. Additionally, these products are
qualified components for the purpose of locking outward-
swinging exit doors against unauthorized egress.They are
designed to release automatically in case of a power failure or
upon activation of an automatic fire alarm system wired to the power
supply fire panel relay.
The Following Conditions of Acceptability Apply:
1) This product is intended for use with Special Locking Arrangements
which are installed in accordance with the manufacturer’s installation and
operation instructions, the Life Safety Code, NFPA 101 of the National Fire
Protection Association and the local authority having jurisdiction.
2) The power for this unit is to be provided by a Listed (ALVY, FULA,
or APHV) Class 2 power supply when designated as a Special Locking
Arrangement (FWAX).
3) The suitability of the lead wires is to be evaluated per the requirements
for the end-use product.
4) If the product is installed in conjunction with a fire alarm control panel,
the wiring from the control unit to this product device shall be for fail-safe
operation.
UL testing was conducted on standard models without accessories. These
locks are not intended or tested for use as a UL Listed Burglar Alarm
System Unit.
3