Dormakaba Oracode 480 Handleiding


Lees hieronder de πŸ“– handleiding in het Nederlandse voor Dormakaba Oracode 480 (5 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 25 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/5
PK3700
2018-06-29 Page 1 of 5
ORACODE 480 - 480i SERIES
INSTALLATION GUIDE FOR DOOR THICKNESS 1 ξ˜Ÿβ„ξ˜" " TO 2
! WARNING
1. Please read and follow all directions carefully.
2. Carefully inspect glass, door frame, door etc., to ensure that the recommended procedures will not cause damage.
dormakaba standard warranty does not cover damages caused by installation.
3. Wear safety glasses when making the holes.
4. All the following operations and testing of the lock to be done with door open.
Tools Required
β€’ Safety Glasses
β€’ ξ˜œβ„ξ˜›" (13mm) Chisel
β€’ ξ˜œβ„ξ˜" (3mm) Drill Bit
β€’ ξ˜šβ„ξ˜™ξ˜›" (4mm) Drill Bit
β€’ 1" Drill Bit or Hole Saw
β€’ 2 ξ˜œβ„ξ˜" (54mm) Hole Saw
β€’ Drill
β€’ Awl or Center Punch
β€’ Screwdriver, ξ˜œβ„ξ˜" slotted
β€’ Phillips Screwdriver (#2)
β€’ Adjustable Square
β€’ Tape Measure
DOOR PREPARATION
INSTALL STRIKE ON WOOD FRAME INSTALL STRIKE ON STEEL FRAME
ADJUST BACKSET OF DEADBOLT INSTALL DEAD BOLT IN DOOR
A = Backset = 2 ξ˜Ÿβ„ξ˜˜" (70mm) or 2 ξ˜Ÿβ„ξ˜" (60mm)
1. Determine which template fits your 480 lock installation, either 2 ξ˜Ÿβ„ξ˜"
(60mm) or 2 ξ˜Ÿβ„ξ˜˜" (70mm) backset.
2. Place appropriate template (supplied) onto door and mark holes.
3. Drill holes as per dimensions on the template, the 1" (25mm) hole to be
on the center line of door thickness.
4. Mortise door edge for dead bolt face plate.
5. Drill 2 ξ˜œβ„ξ˜" from both sides of the door to prevent unsightly damage.
For maximum
security,
install
reinforcing
plate.
Door stop
2
1
3
Install long screws in
door stop side.
Do not remove tape
Do not remove tape
Slot at the bottom
The dead bolt is pre-set at 2 ξ˜Ÿβ„ξ˜˜" (70mm)
backset. Proceed as illustrated to change to
2 ξ˜Ÿβ„ξ˜" (60mm) backset, if required.
1" (25mm)
2 ξ˜œβ„ξ˜" (54mm) Hole saw
1A 1B
2 3
1C
PARTS LIST
1. Outside Housing Assembly (1)
2. Bar Code Label (1)
3. Outside Housing Gasket (1)
4. Dead Bolt (1)
5. Inside Trim Assembly (1)
6. Machine Screw, Pan Head, SS, PH #3, 12-24 (1)
7. Machine Screw, Pan Head, ZP, PH #2, 8-32 (2)
8. Machine Screw, Pan Head, ZP, PH #2, 6-32 (2)
9. Split Lock Washer, No. 8, SS 18-8 (2)
10. Split Lock Washer, No. 12, SS (1)
11. Machine Screw, Flat Head, Brass, PH #2, 8-32 x ξ˜—β„ξ˜™ξ˜›" (2)
12. Dust Box (1)
13. Striker Plate (1)
14. Wood Screw, PH #2, #8 x 1" (4)
15. Wood Screw, PH #2, #8 x 3” (2)
16. Reinforcing Plate (1)
17. Tail Piece Door 1 ξ˜Ÿβ„ξ˜" to 2" (1)
18. Cap (1)
19. Override Key (May be shipped separately) (1)
20. Battery Cell, AA Alkaline (3)
21. Key Cylinder (May be shipped separately) (1)
22. Inside Cover (1)
23. Machine Screw, Flat Head, SS 304, PH #2, 6-32 x .750 (1)
LOCK DIAGRAM
When installing the lock, please carefully slide post
through dead bolt holes.
A
KEY OVERRIDE CYLINDER
If cylinder is not already assembled in the lock,proceed as follows:
ADJUST LOCK HANDING ON OUTSIDE HOUSING ASSEMBLY
4. Wire must not be pinched
when re-installing back plate
5. Re-assemble back plate using
screws as shown
1. Remove 4 screws
2. Remove back plate
May be necessary to
loosen post to remove
back plate
β€œRetaining ring”
opening at 12 o’clock
β€œWire ring” opening far
from slot Groove at 6 o’clock Groove at 12 o’clockRotate to change
from RH to LH
Hold from rotating
Slot Slot
If required, re-tighten post
while making sure not to
pinch retaining ring
Override Switch
WARNING
Posts are mandatory for Fire
Certification and should never
be removed.
Right hand (RH) Left hand (LH)
Install key cylinder
4
5
ASSEMBLE TAIL PIECE REMOVE INSIDE COVER ASSEMBLE OUTSIDE HOUSING
Click in place
Run cable through door
and under the dead bolt
Remove tape
Run cable through inside
trim back plate slot
6 7 8
INSTALL INSIDE TRIM ASSEMBLY
INSTALL INSIDE COVER
9
10
1. All screws should be tightened properly
2. Connect batteries after tightening all screws
3
1
2
V2
V1
W1
PK3700
2018-06-29 Page 2 of 5
For 480i Lock Programming with M-Unit
LOCK PROGRAMMING
MAINTENANCE WHEN REQUIRED
TESTING THE OPERATION OF THE LOCK
TESTING THE MECHANICAL OVERRIDE (with door open) COVER THE KEY HOLE
Perform all the following with the door open.
1. Project the dead bolt if it is not projected.
2. Turn outside thumbturn, the deadbolt
must not retract. See Fig. 1.
3. Enter code.
4. Retract dead bolt from outside.
See Fig. 2.
5. Wait 15 seconds.
6. Rotate outside thumbturn to
project the dead bolt.
7. Rotate inside thumbturn to retract
the dead bolt. See Fig. 3 & Fig. 4.
1. Project the dead bolt from outside or inside.
2. Insert key and rotate it clockwise until it stops. See Fig. 4 & Fig. 5.
3. Rotate outside thumbturn to retract the dead bolt. See Fig. 6.
NOTE: The key override always rotates clockwise.
IMPORTANT: If your lock is already pre-programmed, you can go directly to section 3 below. Otherwise, follow the
instructions in sections 1 and 2 below to program the lock.
1. MAINTENANCE UNIT
To program the lock, you will need a Maintenance Unit running the Oracode application and
the correct door configuration. You will need to login on the Kaba e-code Web Site (www.
kaba-ecode.com) with a valid Username and Password in order to create the door and
download it to the Maintenance Unit. If necessary, contact the Kaba Technical Support
Hotline (1-888-217-5654 US & Canada), (1-514-340-9025 International) or contact your
Oracode representative for assistance.
1. TIME PROGRAMMING
The time is set automatically in the lock when the lock is programmed. The Oracode lock time should then be reset
every year with the Maintenance Unit to ensure accurate time.
The lock has an internal battery back-up that keeps the internal time accurate for a minimum of four weeks when
the lock's batteries are disconnected. If this period is surpassed and the lock time is lost, the green LED will blink
twice after a valid code is entered, and the red LED will blink twice after a code is refused. This indicates that the
time must be reset with the Maintenance Unit.
2. RESET TO FACTORY DEFAULT
NOTE: You will need to reprogram the lock with a Maintenance Unit after you perform a Reset to Factory Default.
Perform the following steps to erase a lock's configuration and restore the default factory settings.
1. Remove the inside cover and remove the batteries.
2. After 1 minute, re-install the batteries. The green LED should blink quickly for 15 seconds.
3. Press #,#,# while the green LED is blinking. The green and red LED should blink one after the other for
15 seconds.
4. Press 1, 2, 3, 4, 5, 6 while the red and green LEDs are blinking. You will hear a longer beep and see a longer green
LED flash when the code is accepted and the default factory setting are restored. If a red LED flashes and a
low-pitch beep is heard, this indicates that the code is refused.
2. LOCK PROGRAMMING
Program the lock using the Oracode Maintenance Unit.
3. CODE GENERATION
Generate a valid code for this door on the www.kabaecodewireless.com website. You will
need to login with a valid Username and Password in order to generate codes.
4. CODE ENTRY AND ACCESS
Enter the valid code on the lock keypad. A short beep can be heard and the green LED flashes for
each key pressed. You will hear a longer beep and see a longer green LED flash when the code is
accepted. The outside turn knob is then engaged for several seconds (5 to 15seconds, depending on
the configuration). If a red LED flashes and a low-pitch beep is heard when the code is entered, this
indicates that the code is refused.
IMPORTANT: Make sure that the door is programmed properly and a valid code is accepted. If a valid
code is not accepted, contact the Kaba Technical Support Hotline.
Fig. 1
Fig. 4 Groove
facing down
Fig. 2 Fig. 3 Fig. 4
Fig. 5 Fig. 6
!
11
12
13
15
14
PK3700
2018-06-29 Page 3 of 5


Product specificaties

Merk: Dormakaba
Categorie: Niet gecategoriseerd
Model: Oracode 480

Heb je hulp nodig?

Als je hulp nodig hebt met Dormakaba Oracode 480 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Dormakaba

Handleiding Niet gecategoriseerd