ES 100 Power Supply
24 Volt D.C. Power Supply
General:
The ES 100 Power Supply is a general purpose power supply providing 24 volt,
full wave filtered DC power at a continuous current rating of 1.3 amps.
Zones:
The ES 100 contains as a standard feature two (2) zone capability. Each zone has
one (1) set of control input terminals and one (1) set of output terminals. The 1.3
amp output rating is applied to either zone as long as the continuous current draw
does not exceed 1.3 amps (Example zone #1 may draw 1.0 amps however zone #2
may not exceed 0.3amps. If zone #2 is not used then zone #1 is rated at 1.3 amps
continuously. The control input may be used as either a dry contact or voltage
input.
Operation:
Trigger input of the ES 100 Power supply will occur by a switch and/or relay. A
Dry Contact input refers to a switch or relay contact that provides no external
voltage to activate the Power Supply. Contacts can be either normally open
contacts or normally closed contacts. These input contacts are connected to
terminals #3 & #4 for zone #1 and terminals #7 & #8 for zone #2. Normally Open
Contacts are use when the ES 8000 Series Exit Device is used in conjunction with
this Power Supply. Normally Close Contacts are used when the DE9000 Delayed
Egress Exit Device is used in conjunction with this Power Supply. A fire alarm
system can be used as the normally open or normally closed contact to trigger the
ES 8000 Series Exit Device or give constant power to the DE9000 Series Delayed
Egress Exit Device. DORMA recommends using the normally closed contacts of
the building’s fire alarm system to control the power being supplied to the
DE9000 Delayed Egress Exit Device from the ES100 Power Supply.
Voltage input refers to an external source of 24 VDC power required to activate
the output terminals. To use zone #1 as a Voltage Input, connect the control
voltage positive (+) wire to terminal #3 and the voltage negative (-) wire to
terminal #2. The external source voltage must have a current rating of 0.045 amps
per zone. Connect the output device such as ES8000 Series Exit Device with
Electric Latch Retraction and DE9000 Series Delayed Egress Exit Device to
terminals #1 and #2. When control voltage is present it will power the output
terminals. To use zone #2 as a Voltage Input, connect the control voltage positive
(+) wire to terminal #7 and the voltage negative (-) wire to terminal #6. The
external source voltage must have a current rating of 0.045 amps per zone.
Connect the output device such as ES8000 Series Exit Device with Electric Latch
Retraction and DE9000 Series Delayed Egress Exit Device to terminals #5 and
#6. When control voltage is present it will power the output terminals.
Circuit Protection:
The ES100 Power Supply is protected agai and overloads by a nst short circuits
0.75 amp slow blowing, field replaceable, fuse in the 120 VAC power line. In
addition a 3.0 amp circuit breaker is provided in the 24 VDC power supply
section to protect both zone #1 and zone #2. Each zone can supply 6.0 amps for
0.5 seconds. This design provides the high inrush currents required for the circuits
of the ES 8000 Electric Latch Retraction Exit Device.
Mechanical and Size Specifications:
Enclosure:
8” Enclosure Height
8” Enclosure Width
4” Enclosure Depth
Electrical Knockouts:
Quantity (2) ½” Diameter (per side)
Quantity (1) ¾” Diameter (per side)
Cover:
Hinged cover with finger pull and locking screw
Rating:
NEMA 1 Enclosure for inside use.
Electrical Specification:
Input Voltage: Input Circuit Protection:
120 VAC, +10% -15% 0.75 AMP slow blow
Input Current:
0.75 AMP Maximum
Output Voltage: Output Circuit Protection:
24 VDC 3.0 Amp Push to reset
Circuit Breaker
Continuous Output Current:
1.3 AMPS total (zone 1 and zone combined)
Surge Output Current: Quantity of Zones:
6.0 AMPS per zone Two (2)
Installation:
1. CAUTION: DISCONNECT INPUT POWER BEFORE BEGINNING THE
INSTALLATION PROCESS, TO PREVENT ELECTRICAL SHOCK AND
EQUIPMENT DAMAGE
2. Installation must be performed by trained personell.
3. The ES 100 Power Supply is designed for surface mounting is a vertical
position. Four holes are provided for mounting the enclosure. All four
mounting holes are accessible by opening the front cover. Use caution when
mounting the enclosure as not to damage the electrical subassembly.
4. There are two (2) ½” and one (1) ¾” knockouts per side to be used as required
for electrical conduit connection.
Maintenance:
In event that is necessary to replace the fuse or electrical subassembly follow the
procedure below. Note: This work is to be done by a qualified personnel.
Fuse Replacement: 0.75 amp slow blow type fuse is mounted in a bayonet style
fuse holder. To remove, press the cap down and turn counter clockwise, remove
and replace the fuse, then replace the fuses and tighten the cap turning clockwise.
Chassis Replacement: CAUTION: Disconnect the 120 Volt A.C. power entering
the ES 100 enclosure. Tag and remove all field installed wires. Remove the four
(4) #8-32 chassis mounting screws and washers. Remove and replace the
electrical circuits and mounting hardware. Connect all the field wire to the correct
terminals. Secure the front door of the ES100 with the locking screw.