Dormakaba EMLTP Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Dormakaba EMLTP (6 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 22 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/6
INSTALLATION
EML310TP, EML320TP
Electromagnetic Locks
© 2019 dormakaba USA Inc
DORMA DRIVE, DRAWER AC, REAMSTOWN, PA 17567 PHONE: (800) 523-8483 (717) 336-3881 FAX: (717) 336-2106
EMAIL: archdw.us@dormakaba.com WEBSITE: dormakaba.us
Pre-Installation Instructions
1. This product must be installed according to all applicable
building and life safety codes.
2. Due to the variety of mounting configurations available
with this product, a survey and assessment of the
physical area in which the product will be installed must
be performed.
3. The door frame must be inspected and deemed structurally
sound prior to installation of the electromagnetic lock. The
structural integrity of the mounting surfaces must be
strong enough to meet or exceed the holding force of the
product.
4. The product must be protected from potential damage
due to intruders or tampering.
5. The product should be installed in a location that will not
hinder or create a potential safety hazard to authorized
personnel accessing the protected area.
6. Because electromagnetic locks are used in a variety of
applications and different door frame configurations, an
experienced installer with knowledge of this product must
make a determination of the optimal mounting method for
this specific application.
7. The components, hardware, installation instructions and
mounting template included with this product are intended
for use on outswinging doors.
8. Do not install this product on the exterior of buildings.
9. Do not use as a doorstop. This will void warranty.
10. Separate accessories must be used in the following
applications:
Inswinging doors
Narrow head jamb situations or center-hung doors
Wherever there is insufficient space on the door
frame header to mount the lock
Glass or Herculite doors that don’t have a door frame
Hollow metal or wood frames where the door
stop is not thick enough to allow the product to
be installed
Wherever an obstruction in the door prevents
installation of the armature plate at a proper height
Doors that do not permit the armature plate to be
mounted low enough to meet the magnet surface
Refer to the page 5 & 6 Product Accessories Guide for
further information. Accessories may impact holding
force.
11. Installation of this product should be done by an
experienced installer with knowledge of this product.
NOTE: It is highly recommended that thread locking compound
be applied to all screws during installation to reduce chance of
screws loosening over extended time.
ISEML310TP
08281550
PCN18040
R08-19GR
1. Mount the electromagnetic lock to the door frame as outlined
on the installation template included with the product.
NOTE: During installation of the armature plate to the door it
is essential that the armature plate remains movable. The
armature plate must be allowed to pivot on the center-mounting
bolt to allow proper alignment with the magnet surface. If the
plate is not aligned with the magnet surface, the lock may lose
holding force or not lock at all.
The head of the armature mounting bolt ships with a rubber
washer affixed to it. This washer should project slightly beyond
the surface of the armature plate. This is to allow the washer
to expand when power is removed and break the air vacuum
between the plate and the magnet surface. If this washer is
removed or trimmed the lock will appear to have some holding
force even when power is removed.
For added safety, thread locking compound has been provided
for the armature plate bolt and the four captive electromagnetic
lock mounting screws.
WARNING: Improper installation, maintenance, inspection
or usage of the product or any related accessories or parts
may cause the electromagnetic lock, armature plate and
associated hardware to disengage and fall, causing serious
bodily injury and property damage. dormakaba Canada Inc.
and/or dormakaba USA Inc. will not be liable to the installer,
purchaser, end user or anyone else for damage or injury
to person or property due to improper installation, care,
storage, handling, maintenance, inspection, abuse, misuse
or act of God or nature involving this product or any related
accessories or parts.
2. Route the power supply connecting wire through the door
frame and into the wire access hole in the top of the magnet
housing. Connecting wire should be of sufficient gauge for
the lock being installed and the distance being run.
Installation Instructions
PLEASE DELIVER ALL INSTALLATION INSTRUCTIONS TO
THE END-USER UPON COMPLETION OF THE INSTALLATION.
3. Set the DC voltage jumpers on JP1 as follows.
For 12V operation two jumpers are used; One on the
two upper pins and the other on the two lower ones.
For 24V operation only one jumper is used to connect
the two center pins (factory setting)
Connect the positive (+) lead from the power supply to
TB1-1. Connect the negative (-) lead from the power
supply to TB1-2. For wiring installations, refer to
figure 1.
4. Delayed Relock Feature - The delayed relock feature can
be used to momentarily release the lock and keep it
unlocked for a time period from 0 to 90 seconds. The
time delay for this feature can be adjusted by carefully
turning the potentiometer in a counterclockwise
direction to increase delay time. Factory setting is zero
seconds (fully clockwise).
NOTE: On the EML320TP double-door model turn both
potentiometers counterclockwise to increase the relock
delay.
2
JP1
JP2
TB1
Alarm Time Setting
Voltage Selection
Light Emitting
Diode (LED)
Time Delay Setting (0-90 secs)
CCW increases time delay
N.C
N.O.
Common
N.C
N.O.
Common
-Common (Ground)
+12/24VDC input
Bond Alert Sensor*
Output contacts SPDT rated at
2.0A @ 30VDC max
Magnet power from
Power Supply
Alarm Status*
Output contacts SPDT rated
2.0A @ 30VDC max.
Power Input Requirements
MODEL 12VDC 24VDC
EML310TP 0.59A 0.29A
EML320TP 1.18A 0.58A
*Shown with Door Open/unlocked
Fig. 1 – Wiring Schematic
Electromagnetic locks must conform to local fire codes, National Building Codes and Life Safety Codes. See your
Local Authority Having Jurisdiction for specific code requirements.
Alarm
Alarm Status Remote Indication - When the door is closed
and an illegal armature plate is detected, the common
contact (TB1-6) and the normally open contact (TB1-7)
are activated for the preset period of time. The alarm
status relay contacts are rated at 30VDC @ 2.0 amps
maximum.
Alarm Time Setting
- Refer to figure 1 (JP2). Note 15 or
30 seconds requires one jumper; 60 seconds requires
no jumper and indefinitely requires two jumpers. Unused
jumpers can be stored on a single pin.
15 Seconds 30 Seconds 60 Seconds Indefinitely
Bond Alert (BA)
Magnet Locked - When the magnet is locked, the common
contact (TB1-3) and the normally open contact (TB1-4)
are closed. The normally closed contact (TB1-5) would be
open.
Magnet Unlocked - When the magnet is unlocked, the
common contact (TB1-3) and the normally closed contact
(TB1-5) are closed. The BA relay contacts are rated 30VDC
@ 2.0 amps maximum.
This feature can detect the quality of the locking bond
between the surface of the magnet and the armature plate.
The sensitivity of this feature is such that a foreign object
with a thickness of .007” (.18mm) is sufficient to allow the
sensor to detect a problem.
Due to the sensitivity of this feature and the necessity to
maintain a reliable locking bond, these surfaces must be
kept free of contaminating materials. Both the lock surface
and the armature plate must be cleaned periodically with
a non-abrasive cleanser. Alignment of armature plate and
magnet is required to ensure proper function of sensor.
LED Local Indication (Light Emitting Diode)
Red LED on solid Maglock is unlocked
Green LED on solid Maglock is locked.
Red LED blinking quickly – Illegal armature plate used;
alarm will be activated.
Each individually encoded armature plate is registered to
match it’s own electromagnetic lock.
3
Anti-Tamper Feature - Two screws prevent insertion of an
Allen wrench into the captive mounting screw opening on
the bottom of the lock. Fig. 3 shows their location. One
screw also secures the wiring cavity cover. The mounting
plate cannot be separated from the lock without removing
these two screws.
Inspection and Maintenance
This product and all related accessories or parts must be
inspected and maintained on a . Contacting quarterly basis
surfaces of the electromagnetic lock and armature plate
must be kept free of contaminating materials. Surfaces
must be cleaned periodically with a non-abrasive cleaner.
All mounting fasteners must be inspected on a quarterly
basis. When properly installed, the ends of the armature
plate allow a slight movement but the plate will feel secure
when grasped at the bolt. There should be no movement
to the mounting bracket or housing of the electromagnetic
lock.
For added safety, thread locking compound has been
provided for the armature plate bolt and the four captive
electromagnetic lock mounting screws.
WARNING: Improper installation, maintenance, inspection or usage
of the product or any related accessories or parts may cause the
electromagnetic lock, armature plate and associated hardware to
disengage and fall, causing serious bodily injury and property damage.
PLEASE DELIVER ALL INSTALLATION
INSTRUCTIONS TO THE END-USER UPON
COMPLETION OF THE INSTALLATION.
For product support, parts and
ordering information contact:
dormakaba USA Inc.
Dorma Drive, Drawer AC
Reamstown, PA 17567 USA
Phone: (717) 336-3881
Fax: (717) 336-2106
Toll Free: (800) 523-8483
Email:archdw.us@dormakaba.com
To Ensure Instant Release All switching devices must be
wired in between the DC power source and the positive
terminal of the lock in Fig 2.
Switching the negative power supply line will not allow
the lock to release immediately. DORMA electromagnetic
locks contain MOV’s for surge suppression and do not
require any additional suppression to be added during
installation. The installation of diodes across the lock input
terminals will cause a delay in release.
Fig. 2 Power Connections
SWITCH
+
-
INCORRECT
CORRECT
+
-
SWITCH
FILTERED DC SUPPLY
FILTERED DC SUPPLY
Fig. 3 – Lock Mounting
Anti-tamper
screw Anti-tamper
and wiring
cavity screw
Captive
mounting
screw


Product specificaties

Merk: Dormakaba
Categorie: Niet gecategoriseerd
Model: EMLTP

Heb je hulp nodig?

Als je hulp nodig hebt met Dormakaba EMLTP stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Dormakaba

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd