LOCK MODES
A maximum of two users can exist in a lock. A lock can operate in either Single Mode or
Dual Custody Mode.
Note:
For a UL listed installation, only one user can be activated.
• Single Mode E
Single Mode defaults to having only a Manager User (User 1) in the lock. A second
user (User 2) can then be added by the Manager User (User 1). (See section on
Manager User Operations.)
In Single Mode only one valid user combination is required to open the lock - the Manager
User (User 1) combination or the User 2 combination.
Note:
Default lock status from the factory is Single Mode with an opening
combination of “502550” for the Manager User (User 1).
• Dual Custody Mode E E
Dual Custody Mode defaults to two users in the lock - User 1 and User 2.
Two user combinations are required to open the lock - the User 1 combination and the
User 2 combination.
Note:
Manager User Operations are not available in Dual Custody Mode.
LOCK OPERATING CONVENTIONS
• The power source for the Auditcon 2 Lock Series is PowerStar
TM Technology.
With this technology an internal generator is used to create all necessary power.
Important Note: The lock must be manually powered before each operation by
briskly turning the dial back and forth .
• To clear a combination or keystroke, press the key.
• If the bolt is not retracted within 4-6 seconds after a valid opening combination is
accepted, the lock will “relock”.
Please note the following operational differences based on the type of bolt you have
installed:
• Dead Bolt (Manual Locking) Technology: There is a “Home” position for the dial on
the lock that is directly related to the manual retraction or extension of the bolt. In the
“HOME” position, the lip of the dial will cover the red “open lock” indicator. The dial
must be positioned here on a lock “Open’’ operation before you can successfully open
the lock. The dial must be turned to the right (CW) to retract the bolt and unlock the
lock. The dial must be turned to the left (CCW) to extend the bolt and lock the lock. The
lock may not open if more than a 5 lb. force is applied to the end or side of the bolt.
• Slide Bolt (Auto Locking) Technology: Once a combination has been entered and
accepted, the lock bolt movement works in conjunction with the bolt works of the
container. When the bolt works are disengaged to open the container, the lock bolt will
slide into the “unlocked” or retracted position. Once the bolt works are extended to the
locked position, the lock bolt automatically slides into the “locked” position. The lock will
not open if force is applied to the end or side of the bolt.
AUDITCON® 2 SERIES
MODELS 52 & T52
OPERATING INSTRUCTIONS
Document Number 3056.025 Rev. A2 - 05/05
LOCK RESPONSES
• The lock is “powered” when simultaneous green
G
and red
R
flashes display with
a beep 8.
• Each keystroke generates a green flash
G
with a beep 8.
• The completion of a step within an operation is indicated by a green flash
G
with a
beep 8.
• The successful completion of an operation is indicated by simultaneous
green
G
and red
R
flashes.
• If a valid combination or combinations are entered to open the lock, the lock will
respond as follows to indicate that the lock is ready to open:
Dead Bolt - 1 slow green flash
G
Slide Bolt - Continuous green flashes
G
... for approx. 5 seconds
• An error is indicated by three red flashes with beeps.
R
8
R
8
R
8
• If the Battery Assist option is included on your lock and a 9 Volt Alkaline has been
installed for Battery Assist, the LEDs will continually flash throughout the duration of a
Time Delay or Open Window period. There is not a battery low indicator for Battery
Assist. If the feature is not functioning properly, check the battery.
TO UNLOCK
1. For a Dead Bolt, place the dial in the Home position.
2. • For Single Mode
EE
EE
E (Factory combination is “502550”.)
Enter Manager User (User 1) or User 2 combination.
G
88888
• For Dual Custody Mode
EE
EE
E EE
EE
E
Enter User 1 or User 2 combination.
G
88
888
Enter the second combination.
G
88
888
Wrong Try Penalty: 5 wrong tries = 3 min. lockout
Each additional wrong try = 3 min. lockout
Red flashes with beeps
R
88
888 will occur during the lockout while lock is powered.
3. For a Dead Bolt, dial right (clockwise) until the lock bolt is retracted. For a Slide
Bolt, rotate the container handle to unlock.
CHANGE COMBINATION
Caution:
When selecting a combination, do not use a birthday or other predictable data that
could give a correlation between the user and the combination.
Before changing a combina-
tion, open the container door to allow testing with the new combination.
1.• For User 1 (Manager User in Single Mode)
Press # and then 1.
G
88
88
8
• For User 2 (Must be added by Manager User in Single Mode)
Press #, # 1 and then .
G
88
88
8
2. Enter current combination. (Factory combination is “502550”.)
G
88
888
3. Enter new six-digit combination.
G
88
888
4. Enter new combination again for verification.
G
R
5. Open the lock with the new combination before closing container.
6. Record new combination and store it in a secure place.
CHANGE LOCK MODE (SINGLE / DUAL CUSTODY)
Note:
Changing the lock mode will reset the combination(s) to “502550”.
1.Press # 2 and then .
G
88
888
2. • If changing from Single to Dual Custody Mode
Enter Manager User (User 1) combination.
G
R
• If changing from Dual Custody to Single Mode
Enter User 1 or User 2 combination.
G
88
888
Enter the second combination.
G
R
SET TIME DELAY AND DELAYED OPENING WINDOW (Model T52 only)
1.Press # 5 and then .
G
88
888
2. • For Single Mode EE
EE
E (Factory combination is “502550”.)
Enter Manager User (User 1) combination.
G
88
888
• For Dual Custody Mode EE
EEE EE
EEE
Enter User 1 or User 2 combination.
G
88
88
8
Enter the second combination.
G
88
88
8
3. Enter number of minutes (01-99) you want to delay lock opening or “00” to disable
time delay.
G
88
888
4. Enter the desired time delay again for verification.
G
88
888
If not “00”, proceed to step 6.
5. Enter number of minutes (01-20) for the delayed opening window.
G
88
888
6. Enter number of minutes for the delayed opening window again for verification.
G
R
Note:
A change in delayed opening will not take effect until after the next
opening of the lock.
TO UNLOCK WITH TIME DELAY SET (Model T52 only)
If operating a Model T52 Lock with Time Delay set to something other than 0, red flashes
R
will display after a combination has been entered and will continue during the delay
while the lock is powered.
Note:
If you have a Time Delay Display unit installed, the display unit will count down to
the end of the time delay period and will count up to the end of the window period.
When the delay time expires, you must power the lock.
Green flashes
G
display with beeps 8 to indicate the opening window is active
and will continue during the window while the lock is powered.
For a Dead Bolt, place the dial in the Home position.
Enter the combination(s) to open the lock.
BATTERY MAINTENANCE
To replace a battery on a battery assist lock, enter a valid combination to unlock the lock
and then open the container door. Locate the battery clip mounted inside the door near
the lock and replace the battery with a fresh 9 Volt Alkaline battery.


Product specificaties

Merk: Dormakaba
Categorie: Niet gecategoriseerd
Model: Auditcon 52

Heb je hulp nodig?

Als je hulp nodig hebt met Dormakaba Auditcon 52 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Dormakaba

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd