Dormakaba 9321 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Dormakaba 9321 (4 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 34 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
INSTALLATION
RCI 9321 / 9323
EASY READ-PROX READER WITH CONTROLLER
© 2022 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: sales_RCI@dormakaba.comIS9321/23
PCN2210
R10-22GR
®
Fig. 1 Fig. 2
Where to install proximity readers
Low to high traffic doors
Interior or exterior doors
Narrow door frames
Inside walls
Architecturally sensitive installations
A black cover is provided with the proximity reader.
A gray Slimline cover is available as 9320/21CAPG.
A white Micro cover is available as 9322/23CAPW.
Where NOT to install proximity readers
Behind metal – RF will not penetrate
On a ferrous metal surface – diminishes read range
Near TVs or monitors – RF will interfere with reader
Note: READER IS WEATHER RESISTANT. , as Do not apply sealant or gaskets to the back of the reader
this may cause condensation build up and adversely affect reader operation.
RCI 9321 Slimline Reader
1. Select appropriate space on wall for reader installation. Ensure
that there are no hidden electrical hazards prior to drilling.
2. Drill hole for reader wiring to pass through.
3. Remove changeable cover from reader if necessary. Cover is
removed by prying off from the bottom of cover only.
4. Pass the readers 8 wires through hole.
5. Hold reader against wall with LED’s at bottom, mark position of
three mounting holes.
6. Drill the three mounting holes as appropriate for the type of
fasteners being used.
7. Install / level the reader and secure with three mounting screws.
8. Install removable cover by engaging top tab and pivoting cover
down over reader. Cover should snap in place when installed
properly.
9. Cover is secured with single screw (provided) on lower edge of
cover. notImportant: Cover screw must be longer than 1/4” or
internal damage will result, voiding warranty.
RCI 9323 Micro Reader
1. Select appropriate space on wall for reader installation. Ensure
that there are no hidden electrical hazards prior to drilling.
2. Holding reader back plate against wall, mark position for two
screw holes and center hole for reader.
3. Drill center hole 13/16” (7/8” max) in diameter. If wall is not
hollow, ensure depth of the hole is at least 2-3/4” deep to
prevent damaging reader/wiring.
4. Drill two smaller mounting holes as appropriate for type of
fastener being used.
5. If necessary, drill hole through wall for wiring to pass through.
6. Screw back plate onto reader until flush with front of reader.
7. Pass reader wires through hole and out other side as
appropriate.
8. Insert reader into hole being careful not to damage wiring.
Secure back plate with two screws provided.
9. Snap the appropriate colored cap over the back plate by
engaging one side and press the other side until it snaps
securely in place.
Mounting Instructions
© 2022 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: sales_RCI@dormakaba.com
Electrical Installation Instructions
1. The reader comes with 16 feet of non-shielded cable. The type of cable used to extend the distance will affect the maximum
distance the reader can be extended.
Switch 2 control board to reader – Maximum cable run = 300 feet (100 m)
2. The micro Reader will be sent out with a RJ45 connector on it. This can be cut off and the cable stripped back ready for wiring.
3. Mount Switch 2 control board into power supply cabinet with stand-offs supplied.
4. Connect reader to control board as shown in Fig. 5. If additional reader is required for in/out operation, wire the reader in
parallel.
5. Reader operates on 12VDC only. Connect reader to power transformer and electric lock as shown in Fig. 6 or Fig. 7.
Note: Unit requires a filtered and regulated power source for proper operation. See our line of power supplies and transformers for
options to use.
Fig. 3 Fig. 4
Micro Reader surface mounted onto wall using back plate.
The plastic end cap is placed over the exposed end of the reader.
Micro Reader surface mounted onto a hollow wall using the back
plate. The plastic end cap is placed over the base plate.
Fig. 5
Proximity Micro Reader Wiring Diagram
Proximity Slimline Reader Wiring Diagram
Note: All installations must conform to local fire, National Building, and Life Safety Codes.
© 2022 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: sales_RCI@dormakaba.com
Fig. 7
Proximity
MicroReader
Red
Fig. 6
Proximity Micro
Reader
or
or
Proximity
Slimline Reader
Proximity
Slimline Reader


Product specificaties

Merk: Dormakaba
Categorie: Niet gecategoriseerd
Model: 9321

Heb je hulp nodig?

Als je hulp nodig hebt met Dormakaba 9321 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Dormakaba

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd