Dimplex LA9MI Handleiding
Dimplex
Airconditioners
LA9MI
Lees hieronder de 📖 handleiding in het Nederlandse voor Dimplex LA9MI (52 pagina's) in de categorie Airconditioners. Deze handleiding was nuttig voor 45 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/52
F568083
ENGLISH
ENGLISH
ENGLISH
ENGLISH ENGLISH ENGLISH
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
Before operating the unit, make sure the installation has been carried out correctly by authorized installer correctly
and precisely following the installation instructions given.
2 ~ 13
2 ~ 13
2 ~ 13
2 ~ 132 ~ 132 ~ 13
FRANÇAIS
FRANÇAIS
FRANÇAIS
FRANÇAISFRANÇAISFRANÇAIS
Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et conservez-le pour toute référence ultérieure.
Avant de faire fonctionner l’unité, assurez-vous que l’installation a été correctement réalisée par un installateur agrée
et dans le strict respect des consignes d’installation fournies.
14 ~ 25
14 ~ 25
14 ~ 25
14 ~ 2514 ~ 2514 ~ 25
ESPAÑOL
Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como
futuro elemento de consulta.
Antes de operar la unidad asegúrese de que la instalación haya sido realizada correctamente por un instalador
autorizado, siguiendo de forma correcta y precisa las instrucciones de instalación dadas.
26 ~ 37
26 ~ 37
26 ~ 37
26 ~ 3726 ~ 3726 ~ 37
DEUTSCH
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese Bedienungsanleitung aufmerksam durch und bewahren Sie
sie für die künftige Verwendung auf.
Vor der Inbetriebnahme dieses Geräts ist sicherzustellen, dass die Montage durch einen autorisierten Händler
fachgerecht entsprechend der Installationsanleitung durchgeführt wurde.
38 ~ 49
38 ~ 49
38 ~ 49
38 ~ 4938 ~ 4938 ~ 49
Model No.
Mono bloc Unit
LA12MI
LA16MI
Operating Instructions
(Mono bloc) Air-to-Water Heatpump System
2
• This manual describes how to operate the Heatpump system.
• Other operation such as water tank, radiator, external thermo controller
and underfl oor system, please refer to respective manufacturer
operation manuals.
SAFETY PRECAUTIONS
T
T
T
TTABLE OF CONTENTS
ABLE OF CONTENTS
ABLE OF CONTENTS
ABLE OF CONTENTSABLE OF CONTENTSTABLE OF CONTENTS
SAFETY PRECAUTIONS
2~3
TECHNICAL DEVICE
INFORMATION
4
CHARACTERISTIC
CURVES
5~6
REMOTE CONTROL
7~10
MONO BLOC UNIT
11
TROUBLESHOOTING
12
INFORMATION
13
NOTE
NOTE
NOTE
NOTENOTENOTE
The illustrations in this manual are for
explanation purposes only and may
differ from the actual unit. They are
subjected to change without notice for
future improvement.
OPERA
OPERA
OPERA
OPERAOPERATION CONDITION
TION CONDITION
TION CONDITION
TION CONDITIONTION CONDITIONOPERATION CONDITION
Water outlet
Temperature (°C)
HEATING Max. 55
Min. 25
Ambient
Temperature (°C)
HEATING Max. 35
Min. -20
NOTICE :
When the outdoor temperature
is out of the above temperature
range, the heating capacity will
drop signifi cantly and mono bloc
unit might stop for protection
control.
The unit will restart automatically
after a short time when the
outdoor temperature is back in
the limits.
To prevent personal injury, injury to others, or property damage, please
comply with the following.
Incorrect operation due to failure to follow instructions below may cause
harm or damage, the seriousness of which is classifi ed as below:
WARNING
WARNING
WARNING
WARNINGWARNINGWARNING
This sign warns of death or serious injury.
CAUTION
CAUTION
CAUTION
CAUTIONCAUTIONCAUTION
This sign warns of injury or damage to
property.
The instructions to be followed are classifi ed by the following symbols:
This symbol denotes an action that is
PROHIBITED.
These symbols denote an action that
is COMPULSORY.
WARNING
WARNING
WARNING
WARNINGWARNINGWARNING
MONO BLOC UNIT
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not
play with the appliance.
Please consult authorized dealer or specialist to clean
the internal parts, repair, install, remove and reinstall the
unit. Improper installation and handling will cause leakage,
electric shock or fi re.
When repair or service refrigeration system, confi rm to
authorized dealer or specialist on usage of specifi ed
refrigerant type. Using of refrigerant other than the specifi ed
type may cause product damage, burst and injury etc.
Do not install the unit in a potentially explosive or fl ammable
atmosphere. Failure to do so could result in fi re.
Do not insert your fi ngers or other objects into the
mono bloc unit, rotating parts may cause injury.
Do not touch the mono bloc unit during lightning, it may
cause electric shock.
Do not sit or step on the unit, you may fall down
accidentally.
ENGLISH
3
WARNING
WARNING
WARNING
WARNINGWARNINGWARNING
POWER SUPPLY
Do not use modifi ed cord,
joint cord, extension cord or
unspecifi ed cord to prevent
overheating and fi re.
To prevent overheating, fi re or electric shock:
• Do not share the same power outlet with other
equipment.
• Do not operate with wet hands.
• Do not over bend the power supply cord.
If the supply cord is damage, it must be replaced
by the manufacturer, its service agent or similarly
qualifi ed persons in order to avoid a hazard.
This unit is equipped with Residue Current Circuit
Breaker (RCCB). It is strongly recommended to
check the operation of the RCCB after installation
and periodically after servicing or maintenance
by authorized dealer to ensure it is in good
working order. Otherwise, it may cause electrical
shock or fi re in case of malfunction.
This equipment is strongly recommended to be
installed with Residual Current Device (RCD)
on-site according to the respective national
wiring rules or country-specifi c safety measures
in terms of residual current.
Stop using the product if any abnormality/failure
occurs and disconnect the power plug or turn off
the power switch and breaker.
(Risk of smoke/fi re/electric shock)
Examples of abnormality/failure
• The RCCB switches off by itself.
• Burning smell, abnormal noise or vibration
sound is observed when the unit is in use.
• Hot water keeps on coming off the unit.
Contact your local dealer immediately for
maintenance/repair.
It is recommended to wear gloves during
servicing or maintenance in order to avoid
hazard.
This equipment must be earthed to prevent
electrical shock or fi re.
Prevent electric shock by switching off the power
supply when:
- Before cleaning or servicing.
This appliance is for multiple uses. All power
supply circuits must be turn off before access to
any of the terminals in the unit, to avoid electrical
shock, burn or fatal injury.
CAUTION
CAUTION
CAUTION
CAUTIONCAUTIONCAUTION
MONO BLOC UNIT
Do not install the unit close to any combustible
equipment or at bathroom. Otherwise, it may
cause electric shock or fi re.
Do not touch the water discharge pipe during
operation.
Do not place anything on top or beneath of the
unit.
Do not touch the sharp aluminium fi n,
sharp parts may cause injury.
Do not use the system during sterilization to
prevent scalding or overheat during shower.
Ensure drainage pipe is connected properly.
Otherwise, leakage may occur.
After a long period of use, make sure the
installation rack does not deteriorate to prevent
the unit from falling down.
The sterilization function fi eld settings must be
confi gured by the authorized dealer according
to local laws and regulation.
REMOTE CONTROL
Do not let the remote control get wet.
Otherwise, it may cause malfunction.
Do not press the buttons on the remote control
with hard, pointed objects. Otherwise, it may
damage the unit.
Do not wash the remote control with water,
benzene, thinner or scouring powder.
Do not inspect or service the remote control by
not inspect or service the remote control by
not inspect or service the remote control by
not inspect or service the remote control by not inspect or service the remote control by not inspect or service the remote control by
yourself. Please consult authorized dealer
yourself. Please consult authorized dealer
yourself. Please consult authorized dealer
yourself. Please consult authorized dealeryourself. Please consult authorized dealer.
.
.
..yourself. Please consult authorized dealer.
Otherwise, it can damage or malfunction.
/
Floor Heating
Panel
Power Supply
Water Tank Unit
Mono bloc Unit
Shower
Remote Control
Product specificaties
Merk: | Dimplex |
Categorie: | Airconditioners |
Model: | LA9MI |
Heb je hulp nodig?
Als je hulp nodig hebt met Dimplex LA9MI stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Airconditioners Dimplex
4 Oktober 2022
4 Oktober 2022
4 Oktober 2022
4 Oktober 2022
4 Oktober 2022
4 Oktober 2022
4 Oktober 2022
4 Oktober 2022
Handleiding Airconditioners
- Airconditioners Electrolux
- Airconditioners Samsung
- Airconditioners Panasonic
- Airconditioners LG
- Airconditioners Bauknecht
- Airconditioners BEKO
- Airconditioners Daewoo
- Airconditioners Inventum
- Airconditioners Siemens
- Airconditioners Toshiba
- Airconditioners Vaillant
- Airconditioners Whirlpool
- Airconditioners Zibro
- Airconditioners Adler
- Airconditioners Alaska
- Airconditioners Amana
- Airconditioners Bestron
- Airconditioners Daikin
- Airconditioners Daitsu
- Airconditioners Diamant
- Airconditioners Eurom
- Airconditioners Frigidaire
- Airconditioners Fuave
- Airconditioners Fujitsu
- Airconditioners GE
- Airconditioners Gorenje
- Airconditioners Gree
- Airconditioners Haier
- Airconditioners Haverland
- Airconditioners Hisense
- Airconditioners Hitachi
- Airconditioners Hotpoint-Ariston
- Airconditioners Kelvinator
- Airconditioners Klarstein
- Airconditioners Lloyd
- Airconditioners Maiko
- Airconditioners Master
- Airconditioners Maxicool
- Airconditioners Melissa
- Airconditioners Midea
- Airconditioners Mitsubishi
- Airconditioners Nedis
- Airconditioners Qlima
- Airconditioners RCA
- Airconditioners Royal Sovereign
- Airconditioners Sanyo
- Airconditioners Saunier Duval
- Airconditioners Sharp
- Airconditioners Suntec
- Airconditioners Tarrington House
- Airconditioners Tatung
- Airconditioners TCL
- Airconditioners Telefunken
- Airconditioners Toyotomi
- Airconditioners Tristar
- Airconditioners Trotec
- Airconditioners Western
- Airconditioners White Knight
- Airconditioners Whynter
- Airconditioners Jocel
- Airconditioners Olimpia Splendid
- Airconditioners Becken
- Airconditioners Camry
- Airconditioners ECG
- Airconditioners Elba
- Airconditioners Heinner
- Airconditioners Rasonic
- Airconditioners Vox
- Airconditioners Wilfa
- Airconditioners Anslut
- Airconditioners Admiral
- Airconditioners Alhafidh
- Airconditioners Campomatic
- Airconditioners Comfee
- Airconditioners Danby
- Airconditioners Infiniton
- Airconditioners Orima
- Airconditioners Svan
- Airconditioners Ardes
- Airconditioners Alpatec
- Airconditioners Inventor
- Airconditioners SereneLife
- Airconditioners Mabe
- Airconditioners National
- Airconditioners Equation
- Airconditioners Godrej
- Airconditioners Airmaster
- Airconditioners AlpicAir
- Airconditioners Commercial Cool
- Airconditioners Coolix
- Airconditioners Taurus-Alpatec
Nieuwste handleidingen voor Airconditioners
4 Oktober 2022
4 Oktober 2022
4 Oktober 2022
4 Oktober 2022
4 Oktober 2022
4 Oktober 2022
4 Oktober 2022
4 Oktober 2022
4 Oktober 2022
4 Oktober 2022