08/52102/0 (UK) Issue 3
EXBURY
The product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility (EMC) EN55014, EN60555-2 and
EN60555-3 These cover the essential requirements of EEC Directives 2006/95/EC and 2004/108/EC
LOXLEY
1
2 3
56
7 8
4
OF
F
ON
A B
110
583
544
24
89
65
519
110
58
3
583
24
94
519
(NO SPACER) (WITH SPACER)
C
L
w
z
AB
*70
Min.
*550
Min.
X
550
C
L
Y
510
205 205
Y
510
C
L
O I
IMPORTANT : THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
Warning: In order to avoid a hazard due to
inadvertent resetting of the thermal cut-out, this
appliance must not be suppliedthrough an external
switching device, such as a timer, or connected to a
circuit that is regularly switched on and off by the
utility.
CAUTION - Some parts of this product can become
very hot and cause burns. Particular attention has
to be given where children and vulnerable people
are present.
This instruction can be found at WWW.DIMPLEX.
CO.UK
General
Unpack the heater carefully and retain the packaging for possible future use,
in the event of moving or returning the re to your supplier. The Remote
Control and batteries are packed separately in the carton. Loose coals are
also packed separately within the carton. When the heater is assembled the
coals are placed on top of the fuel bed.
The re incorporates a ame effect, which can be used with or without heating,
so that the comforting effect may be enjoyed at any time of the year. Using
the ame effect on its own only requires little electricity.
The heater is designed for use inset into a 407mm (16”) or 457mm (18”) wide
by 559mm (22”) high replace opening or freestanding - see also section
‘Installation in a re place opening’.
Before connecting the heater check that the supply voltage is the same as
that stated on the heater.
To reduce heat loss and to prevent any chimney up draught affecting the
operation of your inset re we recommend that the chimney ue is sealed off.
Please note: Used in an environment where background noise is very low, it
may be possible to hear a sound which is related to the operation of the ame
effect. This is normal and should not be a cause for concern.
Installation in a Fireplace Opening
At the rear of the re, an adjustable foot provides for levelling the re where the
base of the replace opening is raised above the level of the hearth. Adjust
the foot by removing the 2 screws and replacing them in the required position.
The metal surround may be removed (six screws) to allow the re to be fully
inset as indicated in Fig. 2B. The minimum opening size required for the re
to be fully inset is *392mm wide, *550mm high and *70mm deep - see . Fig. 1
Alternatively the metal surround may be left on and positioned freestanding
against a wall as indicated in Fig. 2A.
To ensure the appliance stability, the re is supplied with a hook and rawl plug.
The rawl plug supplied is suitable for use in block walls (special fasteners
required on stud walls).
Spacer attached - Fig. 3A: In the event that the re is to be positioned
against a wall with the metal spacer attached, the xing position of the hook
is indicated by ‘X’ in Fig. 3A. When the hook is securely fastened, centre the
re to the hook. Lift the re up and over the hook (see z’ in Fig. 4) ensuring
that the surround (see w’ in engages the hook.Fig. 4 )
No Spacer attached - Fig. 3B: In the event that the re is to be positioned
fully inset without the metal spacer, the xing position of the hook is indicated
by ‘Y’ (the hook can be positioned on either side of the re) in Fig. 3B. When
the hook is securely fastened, position the top outer slot on the re (see Fig.
3B) alongside the hook, lift the re up and over the hook so that the top outer
slot on the re engages the hook.
Electrical connection
WARNING – THIS APPLIANCE MUST BE EARTHED.
This heater must be used on an AC ~ supply only and the voltage marked on
the heater must correspond to the supply voltage.
Before switching on, please read the safety warnings and operating
Instructions.
Important Safety Advice
When using electrical appliances, basic
precautions should always be followed to reduce
the risk of re, electrical shock and injury to
persons, including the following:
If the appliance is damaged, check with the
supplier before installation and operation.
Do not use outdoors.
Do not use in the immediate surroundings of a
bath, shower or swimming pool.
Do not locate the appliance immediately below a
xed socket outlet or connection box.
This appliance can be used by children aged form
8 years and above and persons with reduced
physical, sensory or mental capabilities or lack
of experience and knowledge if they have been
given supervision or instruction concerning use
of the appliance in a safe way and understand the
hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall
not be made by Children without supervision.
Children of less than 3 years should be kept away
unless continuously supervised. Children aged
from 3 years and less than 8 years shall only
switch on/off the appliance provided that it has
been placed or installed in its intended normal
operating position and they have been given
supervision or instruction concerning use of the
appliance in a safe way and understanding the
hazards involved. Children aged from 3 years and
less than 8 years shall not plug in, regulate and
clean the appliance or perform user maintenance.
Do not use this appliance in series with a
thermal control, a program controller, a timer
or any other device that switches on the heat
automatically, since a re risk exists when the
appliance is accidentally covered or displaced.
This appliance is not equipped with a device to
control the room temperature.
Do not use this appliance in small rooms when
they are occupied by persons not capable of
leaving the room on their own, unless constant
supervision is provided.
Ensure that furniture, curtains or other
combustible material are positioned no closer
than 1 metre from the appliance.
In the event of a fault unplug the appliance.
Unplug the appliance when not required for long
periods.
Although this appliance complies with safety
standards, we do not recommend its use on deep
pile carpets or on long hair type of rugs.
The appliance must be positioned so that the plug
is accessible.
If the supply cord is damaged it must be replaced
by the manufacturer or service agent or a
similarly qualied person in order to avoid a
hazard.
Keep the supply cord away from the front of the
appliance.
Warning: In order to avoid overheating, do not
cover the appliance. Do not place material or
garments on the appliance, or obstruct the air
circulation around the appliance, for instance
by curtains or furniture, as this could cause
overheating and a re risk.


Product specificaties

Merk: Dimplex
Categorie: Openhaard
Model: EBY15AB

Heb je hulp nodig?

Als je hulp nodig hebt met Dimplex EBY15AB stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Openhaard Dimplex

Handleiding Openhaard

Nieuwste handleidingen voor Openhaard