Dimplex DS170 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Dimplex DS170 (44 pagina's) in de categorie Warmtepomp. Deze handleiding was nuttig voor 27 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/44
Manual ref: 1898064
Edition n°: 23.05
Installation manual DS170
Pilot for heat pump
Ref. 890003
The information contained in this document is non-contractual. we reserves the right to modify the technical speci cations or characteristics of any of their appliances without prior notice.
Pilot for HRC70 & HTi70 heat pumps
- INSTALLATION DS170uk PILOT MANUAL-
2
TABLE OF CONTENTS
1 - SAFETY INFORMATION ................................. 4
2 - PLEASE READ IMMEDIATELY ........................ 6
2.1 - Conservation of documents ............................................................6
2.2 - Symbols used ........................................................................................6
2.3 - Abbreviations and acronyms ...........................................................6
2.4 - Delivery terms and conditions ........................................................6
2.5 - Storage and transport ........................................................................6
2.6 - Handling .................................................................................................6
2.7 - Unpacking ..............................................................................................7
2.8 - Rating plate ............................................................................................7
2.9 - End of life of the appliance ...............................................................7
3 - INTRODUCTION ............................................. 7
3.1 - General information ...........................................................................7
3.2 - Packaging ...............................................................................................7
3.3 - Accessories (included) .......................................................................7
3.4 - Accessories available as optional extras ......................................8
3.4.1 - Installation ..................................................................................................................8
3.4.2 - Control ..........................................................................................................................8
3.5 - Dimensions ............................................................................................8
3.6 - Operating principles ...........................................................................9
4 - INSTALLATION .............................................. 11
4.1 - Placement choice...............................................................................11
4.1.1 - Appropriate placement choice ..........................................................................11
4.1.2 - Integration ................................................................................................................11
4.1.3 - Hold to the wall .......................................................................................................11
4.2 - Cold Water Supply .............................................................................11
4.3 - Building Regulation G3 Discharge Requirements .................12
4.3.1 - Discharge Pipe D2 ..................................................................................................12
4.3.2 - Worked Example .....................................................................................................13
4.3.3 - Termination of discharge pipe ...........................................................................13
4.4 - Hydraulic installation ........................................................................13
4.4.1 - Recommendations for heating circuit ............................................................13
4.4.1.1 - Back ow prevention device ...............................................................13
4.4.1.2 - Cross sections, purging of the heating circuits ...........................13
4.4.1.3 - Desludging tank .....................................................................................13
4.4.1.4 - Preparing the hydraulic circuit (rinsing) ........................................14
4.4.1.5 - Frost protection ......................................................................................14
4.4.1.6 - Under oor heating ................................................................................14
4.4.1.7 - Thermostatic valves...............................................................................14
4.4.1.8 - Treatment of the water in the heating circuit ..............................15
4.4.1.8.1 - Filling water ..........................................................................15
4.4.1.8.2 - Treatment of the heating circuit ...................................15
4.4.1.8.3 - Purging the installation ...................................................15
4.4.1.8.4 - Connecting the pressure relief valve ..........................16
4.4.2 - Recommendations for sanitary circuit ............................................................17
4.4.2.1 - Cold Water Inlet with Inlet Group ....................................................17
4.4.2.1.1 - Expansion Vessel ................................................................17
4.4.2.1.2 - Balanced Cold Water Supply ..........................................17
4.4.2.1.3 - Drain valve ............................................................................17
4.4.2.2 - Hot Water Outlet ....................................................................................17
4.4.2.2.1 - Thermostatic Mixing Valve..............................................17
4.4.2.2.2 - Pipe Insulation ....................................................................17
4.4.2.3 - Discharge pipes from safety devices ..............................................18
4.4.2.3.1 - Discharge Pipe D1..............................................................18
4.4.2.3.2 - Discharge Pipe D2..............................................................18
4.4.2.3.3 - Tundish ..................................................................................18
4.4.3 - Hydraulic connections ..........................................................................................18
4.4.3.1 - Second circuit kit ....................................................................................19
4.5 - Electrical connections ......................................................................19
4.6 - Connection to the Heat pump and to the accessories
for control .............................................................................................20
4.6.1 - Control connection towards the Heat pump ...............................................20
4.6.2 - Ambient temperature control ............................................................................20
4.6.3 - Exterior sensor .........................................................................................................20
4.6.4 - Second circuit ..........................................................................................................21
4.6.4.1 - Second circuit - Circulator ...................................................................21
4.6.4.2 - Second circuit - Room thermostat ...................................................21
4.6.5 - Under oor safety device of the 65°C safety aquastat (OPT)
with manual reset (OPT) .....................................................................................21
5 - SET-UP ........................................................... 21
5.1 - Before set-up ............................................................................................................... 21
5.2 - Check watertightness.......................................................................21
5.3 - Starting set-up ....................................................................................22
5.4 - Step 1: Circuit choice ........................................................................22
5.5 - Step 2: Filling .......................................................................................22
5.6 - Step 3: Purging the installation ....................................................22
5.7 - Step 4 : Choosing the back-up ......................................................22
5.8 - Step 5: Finishing set-up ...................................................................22
5.9 - 1st use ....................................................................................................22
- INSTALLATION DS170uk PILOT MANUAL- 3
6 - SETTINGS AND FUNCTIONS ....................... 23
6.1 - Control panel .......................................................................................23
6.1.1 - Keypad ........................................................................................................................23
6.1.2 - Display ........................................................................................................................23
6.2 - Menus ....................................................................................................24
6.3 - Actions to be activated using a combination of buttons ....24
6.4 - List of parameters which can be set ..........................................24
6.5 - Description of functionalities ........................................................27
6.5.1 - Functions related to heating ..............................................................................27
6.5.1.1 - AUTO temperature (heat curve) .......................................................27
6.5.1.2 - Lowering of the temperature ............................................................27
6.5.1.3 - Auto-adaptability ...................................................................................27
6.5.1.4 - Ambient temperature reactivity .......................................................27
6.5.2 - Programming and timeout functions .............................................................27
6.5.2.1 - Anticipation of return from holiday ................................................27
6.5.2.2 - Automatic summer/winter changeover ................................................................28
6.5.3 - Ambient temperature and heating circulation control functions ........28
6.5.3.1 - Ambient temperature sensor hysteresis........................................28
6.5.3.2 - Heating circulator speed .....................................................................28
6.5.3.3 - Heating circulator control ...................................................................28
6.5.3.4 - Anti-cold radiators .................................................................................28
6.5.4 - Functions related to the production of domestic hot water ..................28
6.5.4.1 - Domestic priority sharing ...................................................................28
6.5.4.2 - Anti-legionellosis protection .............................................................28
6.6 - Heat pump circulator speed ..........................................................28
7 - MAINTENANCE AND TROUBLESHOOTING 29
7.1 - Maintenance ........................................................................................29
7.2 - Diagnostics ...........................................................................................29
7.2.1 - Loading the operating history ...........................................................................29
7.2.2 - Consulting the current operating state of the system ..............................29
7.2.3 - Water sensors ...........................................................................................................30
7.2.4 - Exterior sensor .........................................................................................................30
7.2.5 - Consulting the counters .......................................................................................30
7.2.6 - Manual operation of components ...................................................................30
7.2.6.1 - Circulator pump .....................................................................................30
7.2.6.2 - 3-way valve ..............................................................................................30
7.2.6.3 - Electrical back-up ...................................................................................30
7.2.7 - Errors indicated by the pilot ...............................................................................31
8 - SPARE PARTS ................................................ 35
9 - WARRANTY ................................................... 36
9.1 - Warranty coverage ............................................................................36
9.2 - Limitations of warranty....................................................................36
9.2.1 - General information ..............................................................................................36
9.2.2 - Cases (not limited to) for exclusion from warranty ....................................36
9.2.2.1 - Usages ........................................................................................................36
9.2.2.2 - Handling ....................................................................................................36
9.2.2.3 - Installation site ........................................................................................36
9.2.2.4 - Electrical connections ..........................................................................36
9.2.2.5 - Hydraulic connections .........................................................................36
9.2.2.6 - Accessories ...............................................................................................36
9.2.2.7 - Maintenance ...........................................................................................36
APPENDIX .......................................................... 37
A1 - Technical speci cations ....................................................................37
A1.1 - General characteristics ..........................................................................................37
A1.2 - EU declaration .........................................................................................................37
A1.3 - Dimensions ................................................................................................................38
A2 - Hydraulic schematic diagrams ......................................................39
A2.1 - Hydraulic connection between the pilot and the heat pump ................40
A2.2 - Minimum  ow rate according to the heat pump model ..........................40
A3 - Wiring diagrams ..................................................................................41
A4 - Recap of functions .............................................................................42
A4.1 - Control panel ............................................................................................................42
A4.1.1 - Keypad ........................................................................................................42
A4.1.2 - Display ........................................................................................................42
A4.2 - Menus ..........................................................................................................................43
A4.3- Actions to be activated using a combination of buttons ..........................43


Product specificaties

Merk: Dimplex
Categorie: Warmtepomp
Model: DS170

Heb je hulp nodig?

Als je hulp nodig hebt met Dimplex DS170 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Warmtepomp Dimplex

Handleiding Warmtepomp

Nieuwste handleidingen voor Warmtepomp