Dimplex DC15 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Dimplex DC15 (10 pagina's) in de categorie Airconditioner. Deze handleiding was nuttig voor 27 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/10
r
MODELS:
DC12 / DC12RC / DC15
INSTRUCTION MANUAL
PORTABLE AIR CONDITIONER
1
IMPORTANT INFORMATION
Carefully read this instruction manual before you install or use
your portable air conditioner. Please retain this manual for
product warranty details and for future reference.
CAUTION
1. Make sure the inlet and outlet vents are never blocked.
2. Ensure the appliance is on a stable, even surface when operating to avoid
water leakage.
3. Do not operate this unit in an explosive or corrosive atmosphere.
4. When switched to cooling, only operate this unit in set temperatures between
17°C and 43°C. For heating, only operate this unit in ambient temperatures
between 5°C and 23°C.
5. Clean the air filter frequently to ensure efficient operation.
6. To prevent compressor damage when the unit has been operating and is
turned off, please wait at least 3 minutes before restarting.
7. This unit needs to be plugged into a 220-240V ~ 50Hz AC, 10 Amp power
outlet.
8. Do not use any extension cords with this unit.
9. This unit is for indoor use only.
10. Open the adjustable air vent and extend the exhaust pipe (and drain pipe, if fitted) to
the closest window before using.
11. Only ever have a professional technician, manufacturer or service agent
replace a damaged power cord.
12. The batteries from the remote control must be removed and disposed of
safely, before the appliance is scrapped.
13. This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety.
14. Children should be supervised to ensure that they do not play with the appliance.
2
PACKAGE CONTENTS
Portable air conditioner
Remote control
Extendable window kit
PARTS
1. Control panel
2. Display screen
3. Adjustable air vent
4. Window kit adaptor
5. Exhaust tube
6. Drain hose (DC12RC only)
7. Cool air inlet
8. Cool air filter
9. Hot air inlet
10. Hot air filter
11. Drain plug
Note: Make sure drain plug (11) is fitted before use.
IMPORTANT
The air conditioner must always be stored and transported upright.
In case of doubt we suggest you wait for at least 24 hours before
operation. (Please keep unit upright at all times)
3
CONTROLS AND DISPLAY
Controls for all models
1. POWER Press the POWER button to turn the unit "ON" or "OFF".
The portable air conditioner is fitted with a compressor delay protection circuit. This
protects the unit from possible damage due to rapid starting and stopping of its
compressor. Compressor operation begins 3 minutes after the unit is switched on or the
mode is switched from dehumidify to air conditioning.
2. FUNCTION Press this button to select cooling, heating or dehumidification.
(The heating function is only available on the DC12RC)
3. TEMP+ This button raises the set temperature by 1°C each time it is
pressed, to a maximum of 30°C. For DC12RC, it can be raised to a
maximum of 25°C.
4. TEMP- This button lowers the set temperature by 1°C each time it is
pressed, to a minimum of 17°C. For DC12RC, it can be reduced to a
minimum of 15°C.
The time taken to reach the desired set temperature will depend on the environment and
the size of the space in which the unit is operating in.
For example, if the ambient temperature is too hot or the room is too large, the rate at
which the temperature descends will be slow as the cooling may be less effective.
4
5. DISPLAY The display indicates the current set temperature or the time setting.
When the set temperature or the timer is adjusted, the new setting is
shown then the display returns to the current set temperature.
The display is also used to show error codes should a fault occur, see ERROR CODES.
6. FAN SPEED Press FAN SPEED to select LOW, MEDIUM, HIGH or AUTO fan speed.
If AUTO fan speed is selected, the unit operates at maximum capacity
and high fan speed while the room temperature is more than 2°C from
the set temperature. When the room temperature is within 2°C of the set
temperature, the unit operates at medium capacity and fan speed. Once
the room temperature equals the set temperature, the unit will operate
at minimum capacity and low fan speed to efficiently maintain the
desired temperature.
When HIGH, MEDIUM or LOW speed is selected, the unit operates at
maximum capacity until the set temperature is reached. The fan
operates at the selected speed
TURBO If the TURBO button is selected, the unit will operate at the highest
speed for 30 minutes before changing to AUTO mode. Press TURBO
or FAN SPEED button to cancel this function. If the unit is in TURBO
mode, the "AUTO" icon will be flashing.
7. TIMER ON/OFF button for the programmable timer.
The timer can be used to turn the unit on automatically after a set
time delay is complete.
1. With the unit OFF, press the "TIMER" button to set the desired time
delay before the unit is to start.
2. Choose the function desired (cooling, heating or dehumidification.)
3. Once the set time delay is complete, the unit will turn on
automatically.
4. If you press the “POWER” button before the time delay is complete,
the delay will be cancelled and the unit will turn on immediately.
5
The timer can be used to turn the unit off automatically after a set
time period is complete.
1. With the unit ON, press the "TIMER" button to set the desired time
for the unit to remain on.
2. Once the set time period is completed, the unit will turn off
automatically.
3. If you press the “POWER” button before the time delay is complete,
the delay will be cancelled and the unit will turn off immediately.
8. SLEEP Press the SLEEP button to select the sleep comfort mode.
When the unit is in cooling mode and sleep mode is selected, the unit
will raise the set temperature 1°C each hour to a maximum of 2°C over
two hours. These temperatures will be maintained for the balance of the
time set and help maximize sleep comfort.
When the unit is in heating mode and sleep mode is selected, the unit
will lower the set temperature 1°C each hour to a maximum of 2°C over
two hours. These temperatures will be maintained for the balance of the
time set and help maximize sleep comfort.
When setting the "sleep comfort" mode please ensure you set the
number of hours required by pressing the TIMER button. The hours set
will be shown on the display by pressing either the TEMP+ or TEMP-
buttons. Please note: This function cannot be used in
dehumidifying mode.
The screen will be blank after 15 minutes of operation, but can be
re-activated when any key is pressed.
WATER DRAIN For cooling only models, the water drain warning indicator is displayed
when the internal condensation container requires emptying. For
reverse cycle models, an E4 error code will be displayed.
For more information, refer to WATER DRAIN


Product specificaties

Merk: Dimplex
Categorie: Airconditioner
Model: DC15

Heb je hulp nodig?

Als je hulp nodig hebt met Dimplex DC15 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airconditioner Dimplex

Handleiding Airconditioner

Nieuwste handleidingen voor Airconditioner