Digitus DA-70610 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Digitus DA-70610 (12 pagina's) in de categorie Meetapparatuur. Deze handleiding was nuttig voor 55 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
USB Power Monitor
Quick Installation Guide
DA-70610
Performance Parameters
1. INPUT voltage: 3V-7V
2. The INPUT current: <3.4A
3. The display shows voltage, current and discharge capacity
Total in 10 groups which can be stored
4. The electric current can be calibrated
5. Function:
ï‚Ÿ Data communication
Test voltage current:
Plug in USB charger and insert the tester, which will directly read voltage current parameters.
The device must have the regular USB connector for input, and a micro USB connector which can
be used directly with any standard USB charger.
Setting Instruction
1. Data clearance:
Hold the button until the first data moving to next. Release the button. The data has been
cleared automatically, and then skip to the next one.
2. Data checking mode:
Double-click the button (0.5S or less) enter to the data view mode, the backlight LED will flash,
and click the button of display to the next data. Double-click to the exit checking mode, and
backlight LED lights flash.
3. High and low voltage indication:
If the voltage is higher or lower than standard, the LCD arrow and LED backlight will flash
promptly for warning. Press and hold on the button 30s until LED lights flash stably.
Power on status:
Connect the power supply to Micro USB or DC to USB cable of the power monitor, LCD display
shows the entire content about 1 second (for checking the LCD screen is defective or not), and
then displays the last data (capacity, data units), higher, lower voltage or currents warning.
Test output capacity of power bank:
Plug in the power monitor to the power bank, and turn on the power monitor. Long press the
button until the capacity data set to zero. Then connect it into the mobile phone charge several
times until the battery of power bank runs out, and then power bank shut down. Disconnect the
monitor with mobile phone and power bank. After that, reconnect the power monitor to the
power bank. Showing capacity on the power monitor is the output capacity of this power bank.
(Please note the actual output capacity is about 60% of the nominal capacity).