Grid-tied PV String Inverter
User Manual
R
SUN-15K-G03
SUN-17K-G03
1. Introduction
1.1 Appearance Introduction
1.2 Parts list
2. Safety warnings and instructions
2.1 Safety signs
2.2 Safety instructions
2.3 Notes for using
3. Operation Interface
3.1 Interface View
3.2 Status Indicator
3.3 Buttons
3.4 LCD Display
4. Product installation
4.1 Select installation location
4.2 Inverter Installation
5. Electrical Connection
5.1 DC input terminal connection
5.2 AC input terminal connection
5.3 The connection of the ground line
- 01 -
- 01 -
- 02 -
- 03 -
- 03 -
- 03 -
- 04 -
- 05 -
- 05 -
- 05 -
- 06 -
- 06-
- 07 -
- 07 -
- 09 -
- 11 -
- 11 -
- 13 -
- 16 -
























































































































































































































































































































































































- 17 -














5.4 Max. over current protection device
5.5 Inverter monitoring connection - 17 -














5.7 Configuration of Datalogger
6. Startup and Shutdown
6.1 Start up the inverter
6.2 Inverter Shutdown
- 18 -
- 18 -
- 19 -
- 19 -
- 19 -

















5.6 Installation of datalogger 












































































- 20 -















- 20 -













- 21 -














7. Zero export function via SUN limiter
7.1 SUN Limiter function wiring diagram
7.2 Connect the SUN limiter to inverter
- 23 -

















7.3 Use of zero export function
8. General Operation
8.1 The initial interface
8.2 Submenus in the Main Menu
8.3 System param setting
8.4 Running param set
- 31 -
- 31-
- 32 -
- 35 -
- 35 -




























































- 24 -















- 29 -
- 29 -


































- 39 -
- 39 -
- 40 -
- 44-















































































9. Repair and Maintenance
10. Error information and processing
10.1 Error code
11. Specification
8.6 Comm. param set
8.5 Protect Param - 37-
- 39 -


























































7.5 Notes while using zero export function
7.4 Zero-export function (Option)
7.6 How to browse the load power of your PV grid-tieplant on monitoring platform?
- 01 -
On-grid inverter can convert solar panel DC power into AC power which can directly input to the
grid. Its appearance is shown below.These models contain SUN-15K-G03 SUN-17K-G03.、

Pic 1.1 Front view 
1.1 Appearance Introducᅵon
Photovoltaic Grid-connected System
1. Introducᅵon

Inverter MeteringPV array Power grid
Family load
About This Manual


How to Use This Manual

Contents may be periodically
updated or revised due to product development. The informaᅵon in this manual is subject to
change without noᅵce. The latest manual can be acquired via service@deye.com.cn
ON
OF F
RS 23 2/ 48 5
RS 48 5
li mi ter
- 02 -
1.2 Parts list
Please check the following table, to see whether all the parts are included in the package
Wall mounᅵng bracket x1
Mounᅵng stainless steel
screws M4×12
x4
Grid-ᅵed PV String Inverter
x1
DC power connectors
(including Inserted spring)
x3
Stainless steel anᅵ-collision
bolt M6×80
x4
AC power connectors x1
User
manual
User manual x1
Square hole sealing plate
(For WIFI funcᅵon)
x1
Datalogger (opᅵonal) x1
Meter(opᅵonal)
x 1
Thre e-Phase Smart M eter
SET ESC
SUN limiter(opᅵonal) x 1
When ordering the sun limiter, it will includes 3pcs CT.
*Sensor Clamp x 3
- 03 -
2. Safety warnings and instrucᅵons
2.1 Safety signs
2.2 Safety instrucᅵons
Improper use may result in potenᅵal electric shock hazards or burns. This manual contains
important instrucᅵons that should be followed during installaᅵon and maintenance. Please
read these instrucᅵons carefully before use and keep them for future reference.
Safety symbols used in this manual, which highlight potenᅵal safety risks and important safety
informaᅵon, are listed as follows:
Shock Hazard:
Cauᅵon, risk of electric shock symbol indicates important safety instrucᅵons,
which if not correctly followed, could result in electric shock.
High Temperature Hazard:
Cauᅵon, hot surface symbol indicates safety instrucᅵons, which if not correctly
followed, could result in burns.
Safety Hint:
Note symbol indicates important safety instrucᅵons, which if not correctly
followed, could result in some damage or the destrucᅵon of the inverter.
Warning:
Warning symbol indicates important safety instrucᅵons, which if not correctly
followed, could result in serious injury or death.
Shock Hazard:
Prohibit disassembling inverter case, there exisᅵng shock hazard, which may
cause serious injury or death, please ask qualified person to repair.
Warning:
Electrical installaᅵon of the inverter must conform to the safety operaᅵon rules
of the country or local area.
Warning:
Inverter adopts non-isolated topology structure, hence must insure DC input and
AC output are electrical isolated before operaᅵng the inverter.
Strictly prohibit grounding the posiᅵve and negaᅵve poles of the PV string.
Otherwise it will damage the inverter.
- 04 -
2.3 Notes for using







 ℃



connect the inverter to the grid.

6. Please install where children can not touch.


disconnect the DC side.


Shock Hazard:


Shock Hazard:


High Temperature Hazard:
 ℃
Please do not touch the inverter case.
- 05 -
3.2 Status Indicator
3. Operaᅵon Interface
Pic 3.1 Front panel display
3.1 Interface View
ACDC AlarmNormal
There are four LED status indicator lights in the front panel of the inverter. Please see table 3.1
for details.
Explanaon
Inverter detects DC input
Low DC input voltage
Grid Connected
Grid Unavailable
Under normal operaᅵng
Stop operaᅵng
Detected faults or report faults
Under normal operaᅵng
Indicator status
●DC
●AC
●NORMAL
● ALARM
on
off
on
off
on
off
on
off
Table 3.1 Status indicator lights
- 07 -
4.1 Select installaᅵon locaᅵon
4. Product installaᅵon
To select a locaᅵon for the inverter, the following criteria should be considered:
WARNING: Risk of fire
● Do not install the inverter in areas containing highly flammable materials or gases.
● Do not install the inverter in potenᅵally explosive atmospheres.
● Do not install in small closed spaces where air can not circulate freely. To avoid overheaᅵng,
always make sure the flow of air around the inverter is not blocked.
● Exposure to direct sunlight will increase the operaᅵonal temperature of the inverter and
may cause output power limiᅵng. It is recommended that inverter installed to avoid direct
sunlight or raining.
● To avoid overheaᅵng ambient air temperature must be considered when choosing the
inverter installaᅵon locaᅵon. It is recommended that using a sun shade minimizing direct
sunlight when the ambient air temperature around the unit exceeds 100°F/40℃.
Pic 4.1 Recommended installaᅵon place
- 08 -
● Install on a wall or strong structure capable of bearing the weight.
● Install verᅵcally with a maximum incline of +/-15°. If the mounted inverter is ᅵlted to an
angle greater than the maximum noted, heat dissipaᅵon can be inhibited, and may result in
less than expected output power.
● If install more than one inverter, must leave at least 500mm gap between each inverter. And
each inverter must be at least 500mm above and below.And must install the inverter at the
place where children cannot touch. Please see picture 4.3.
● Consider whether the installaᅵon environment is helpful to see the inverter LCD display and
indicator status clearly.
● Must offer a venᅵlate environment if inverter installed in the airᅵght house.
Safety Hint:
Do not place or store any items next to the inverter.
Pic 4.2 Installaᅵon Angle
≀15
°
- 9 -
≥500mm
≥500mm
Pic 4.4 Inverter Installaᅵon
4.2 Inverter Installaᅵon
The inverter is designed according to the wall mounted type installaᅵon, please use the wall
mounted (the brick wall of the expansion bolt) when installing.
Pic 4.3 Installaᅵon Gap
Anchoring
Mounᅵng bracket
Stainless steel screws
Inverter
- 10 -
2. Ensure that the posiᅵon of the installaᅵon holes on the wall is in accordance with the
mounᅵng plate, and the mounᅵng rack is horizontally placed.
3. Hang the inverter to the top of the mounᅵng rack and then use the M4 screw in the
accessory to lock inverter heat sink to the hanging plate, to ensure that the inverter will not
move.
Procedure shows below:
1. Locate on the appropriate wall according to the bolt posiᅵon on the mounᅵng bracket, then
mark the hole.On the brick wall, the installaᅵon must be suitable for the expansion bolt
installaᅵon.
Pic 4.5 Inverter hanging plate installaᅵon
Pic 4.6 Inverter installaᅵon
- 11 -
5.1 DC input terminal connecᅵon
5 Electrical Connecᅵon
Table 5.1 DC Cable Specificaᅵons
1. Switch the Grid Supply Main Switch(AC)OFF.
2. Switch the DC lsolator OFF.
3. Assemble PV input connector to the inverter.
Safety Hint:
Please don’t connect PV array posiᅵve or negaᅵve pole to the ground, it could
cause serious damages to the inverter.
Safety Hint:
Before connecᅵng inverter, please make sure the PV array open circuit voltage is
within the 1000V of the inverter.
Safety Hint:
Before connecᅵon, please make sure the polarity of the output voltage of PV
array matches the “DC+” and “DC-” symbols.
Safety Hint:
Please use approved DC cable for PV system.
Pic 5.1 DC+connector (MC4) Pic 5.2 DC-connector (MC4)
Cable type Range Recommended value
Cross seconmm 
Industry generic PV cable
(model: PV1-F)
4.0~6.0
(12~10AWG) 4.0(12AWG)
- 12 -
The steps to assemble the DC connectors are listed as follows:
a)Strip off the DC wire about 7mm, disassemble the connector cap nut (see picture 5.3).
b) Crimping metal terminals with crimping pliers as shown in picture 5.4.
c) Insert the contact pin to the top part of the connector and screw up the cap nut to the top
part of the connector. (as shown in picture 5.5).
Pic 5.3 Disassemble the connector cap nut
7mm
7mm
Pic 5.4 Crimp the contact pin to the wire
Pic 5.5 connector with cap nut screwed on
- 13 -

5.2 AC input terminal connecᅵon
shown as
picture 5.6


-

Outside cable

Cable CSAModel Cable outer dia BreakerAWG Max cable length
 106mm 20-25mm 

Warning:


panel needs to be blocked by the opaque material and the DC switch should


Warning:


- 14 -
The AC output connector is divided into three parts: matching socket, sleeve and sealing-
sleeve, as shown in picture 5.7, the steps are as follows:
Step 1: Remove the cable sealing ring and sleeve in sequence from the AC connector.
Step 2: Use strippers to strip the protecᅵve sheath and insulaᅵon layer of the AC cable to the
right length, as shown in Picture 5.8.
Step 3: Insert the cable (L1, L2, L3, N PE) into the sealing sleeve.
Step 4: Use the hexagon screwdriver, loosen the bolts of the socket in turn, and insert each
cable core into the corresponding jack, and set each screw. The connecᅵon hole of AC
connecᅵon terminal labeling is shown in Picture 5.9.
Warning:
Be careful to disᅵnguish the L1, L2,L3,N and PE of the AC cables.
1. Matching socket 2.Sleeve 3.Sealing core 4.Sealing nut
Pic 5.7 AC connector structure
Pic5.8 Strip AC cable
8~15mm
40mm
1234
- 15 -




- 16 -
5.3 The connecᅵon of the ground line
Good grounding is good for resisᅵng surge voltage shock and improving EMI perfor-
mance.Therefore, before connecᅵng AC, DC and communicaᅵon cables, you need to ground
the cable firstly. For a single system, just ground the PE cable. For mulᅵple machine systems,
all PE cables of the inverter need to be connected to the same grounding copper platoon to
ensure the equipotenᅵal connecᅵon. The installaᅵon of the shell ground wire is shown as
picture 5.11.
Warning:
Inverter has built-in leakage current detecᅵon circuit, If an external leakage
current protecᅵon device is connected, its operaᅵng current must be greater
than 300 mA or higher, otherwise inverter may not work properly.
Pic 5.11The installaᅵon of the shell ground wire
- 17 -
5.4 Max. over current protecᅵon device
In order to protect the inverter AC connecᅵon, it is recommended to install a circuit breaker to
prevent overcurrent. See table 5.3 below.
Rated output
voltage(V)
Inverter Rated output
current(A)
Current for protecon
device(A)
SUN-17K-G03 230 3024.6
SUN-15K-G03 230 3021.8
Table 5.3 Recommended current protector specificaᅵons
5.5 Inverter monitoring connecᅵon
Inverter has the funcᅵon of wireless remote monitoring. The inverter with Wi-Fi funcᅵon is
equipped with Wi-Fi Plug to connect the inverter and network. Wi-Fi Plug's operaᅵon,
installaᅵon, Internet access, APP downloading and other processes are detailed in the
instrucᅵons.
PC
Router
WIFI
GPRS
Web Server
Phone
Pic 5.12 Internet monitoring soluᅵon
- 18 -







5.6 Installaᅵon of datalogger

5.7 Configuraᅵon of Datalogger

- 19 -
6. Startup and Shutdown



that the two inputs be connected to the same number of photovoltaic modules.





6.1 Start up the inverter
6.2 Inverter Shutdown

1. First switch on the AC breaker.




crystal will show that the inverter is self-checking.

NORMAL indicator light is on.



connector. The inverter will close the LCD and all LED within two minutes.
- 20 -







are the interface between three sets of current sensor and one set of control terminals. SUN limiter
will collect voltage and current from these interfaces and send control signals to the inverter.
L1 L1(L)L1(K)L2(L)L2(K)L3(L) L3(K) + -L2 L3 N
7 Zero export funcᅵon via SUN limiter
7.1 SUN Limiter funcᅵon wiring diagram
Pic 7.1 SUN Limiter view






- 21 -
U
V
L1(L)
Solar panels
Load
Distribution Box
Limiter
Control signal
L1(K)
L2(L)
L2(K)
L3(L)
L3(K)
L1
L2
L3
N
W
N
Control signal

of the AC switchis determined by the load capacity.The AC switch we recommend to connect to
the inverter output refer to Table 5.2.
7.2 Connect the SUN limiter to inverter



Pic 7.2 Wiring diagram







power of the phase. So the clamp senor should be connected to the same phase as the before.





- 22 -
Pic 7.5 Waterproof terminal Pic 7.6 Connect limiter to inverter
1 2
limiter
+ -
1
2



the same on the waterproof terminal of the inverter. Twist the waterproof terminal and connect

the terminal to the interface of the SUN limiter. The other side of the line should be connected to
the control terminal.
Pic 7.3 Clamp Senor Pic 7.4 Clamp Senor internal arrow
L
K
Load
- 23 -
Pic 7.9 Limit switch







be completed. Shown as picture 7.10.


1. Turn on the AC switch





7.3 Use of zero export funcᅵon
Pic 7.7 Connect terminal to inverter
System Para m
Param
< <
0FF <<Limiter
Run
*Fun GFDI OFF
- 24 -
7.4 Zero-export funcᅵon (Opᅵon)
7.4.1 Zero-export funcᅵon via energy meter




to connect the energy meter.

-

switch are determined by the power of load.

connect the DC switch. The voltage and current of the switch depend on the PV array you
access.
Utility Power:
20W

ON <<Limiter



chapter 7.9.









*Fun GFDI OFF
* This item is not avaiable for some FW verison
- 26 -
Pic 7.13 Eastron meter
Eastron SDM630MCT
1 2 3 4 5 6
L1
L2
L3
N
P1P2
S1S2
P2 P1
S1S2
P1P2
S1S2
3 PHASE 4 WIRE
15 16 17 18 19 20
Grid voltage
sampling
Auxiliary
power supply
Current inputs
RS 485
RS 485 A RS 485 B
14 13 12
GND
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18 19 20
P
M
E
U/IESC
Eastron
Pic 7.13 Connecᅵon diagram of Eastron meter
Solar Panel array
Inverter
meter
AC Breaker
Grid
RS485 Communication
Family load
N L3 L2 L1 LA NA
S2 S1 S2 S1 S2 S1
GND B A
CT2
CT1
CT3
White line
black line
White line
black line
White line
black line
L1 L2 L3 N
N L3 L2 L1
VCC_5V 485_B
485_A
485_A
485_B
GND
GND
RS 485
Male connector
RS 485
Female
connector
1
2
3
4
1 2 3 4 5 6 7 8
9 10 11 12 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0
P
M
E
U/IESC
Eastron
Note: the arrow direction towards
the inverter
ON
OFF
RS2 32/ 485
RS4 85
lim iter
- 27 -
ON
OFF
RS2 32/ 485
RS4 85
lim iter
Warning:
Ensuring grid input cables connect 1/4/7/10 port of energy meter, and inverter
AC output cables connect 3/6/9/10 port of energy meter when connecᅵng.
Pic 7.14 CHINT meter
Three-Phase Smart Meter
SET ESC
1 74 10
2524
3 96 10
RS 485
CHNT DTSU666
(3,6,9,10)
(1,4,7,10)
Pic 7.15 Connecᅵon diagram of CHINT meter
Solar Panel array
Inverter
meter
AC Breaker
Grid
RS485 Communication
Family load
1 74 10
2524
3 96 10
Three-Phase Smart Meter
SET ESC
L1 L2 L3 N
L1 L2 L3 N
N L3 L2 L1
VCC_5V 485_B
485_B
485_A
485_A
GND
RS 485
Male connector
RS 485
Female connector
1
2
3
4
- 28 -
7.4.2 Use of zero-export funcᅵon
Pic 7.14 Meter switch
System Para m
Param
< <
Island OFF
0FF <<Meter
Run

1. Turn on the AC switch.





picture 7.14.
Meter Power:
20W















- 29-
Safety Hint:



(when using SUN limiter, the arrow of current sensor points to the load)
High Temperature Hazard:


cannot able to normal operate.



Warning:


inverter more responsive to limit the power.


grid(
feed into grid)
But please
don’t setup “Meter ON”




- 30-
And then choose your system type as “Self-consumpᅵon”
Secondly, go to plant page, if it shows the PV power, load power and grid power, which means
the configuraᅵon is correct.
-31 -



-

inverter.



Start

Setup
*PV VA
System param
Running param

Comm. param

Device

Fault record
LCD Main menu
Total DC Power
PV1 and Power
UA and UB
UC and Freq
*Meter
Time
E-Day and E-Total
*ImpEp and Total

*Load
*LoadEp and Total

successfully. Otherwise, it won't show.
- 32-
Pic 8.2 The iniᅵal interface
Power: 0W
State: Standby
Power: 0W
State: Com.Error
Press UP or Down, you can check inverter DC voltage, DC current, AC voltage, AC current and
inverter temperature.
Pic 8.3 PV input voltage and current
informaᅵon
PV1: 0.0V 0.0A
Pic 8.5 Grid voltage and current informaᅵon
UA: 234V 0.0A
UB: 0V 0.0A
Pic 8.6 Grid voltage and frequency
UC: 0V 0.0A
Freq: 0.00Hz
Pic 8.7 Time
21 - 05 - 2020
15 : 57 : 08
Pic 8.8 Meter power
Meter
Power: 0W
ImpEp: Daily energy purchased from grid;
Total: Total energy purchased from grid.
Pic 8.9 Electrical energy
ImpEp: 0.00KWh
Total : 0.00KWh
ExpEp: Daily energy sold to grid;
Total: Total energy sold to grid.
Pic 8.10 Electrical energy
ExpEp: 0.00KWh
Total : 0.00KWh
Pic 8.4 Load power
Load
Power: 0W