Dell PowerEdge
C410x
Technical Guide
With up to 16 PCIe
devices and up to 8
servers, the Dell
PowerEdge C410x
expansion chassis
maximizes space, weight,
energy and cost
efficiency with
unprecedented flexibility.
ii Dell PowerEdge C410x Technical Guide
This document is for informational purposes only and may contain typographical errors and technical
inaccuracies. The content is provided as is, without express or implied warranties of any kind.
Dell, the DELL logo, PowerEdge, EqualLogic, OpenManage, and ReadyRails are trademarks of Dell, Inc. Intel is
a registered trademarks of Intel Corporation in the U.S. and other countries. Microsoft, Windows, and Windows
Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or
other countries. Novell and SUSE are registered trademarks of Novell, Inc. in the United States and other
countries. Other trademarks and trade names may be used in this document to refer to either the entities
claiming the marks and names or their products. Dell disclaims proprietary interest in the marks and names of
others.
©Copyright 2013 Dell Inc. All rights reserved. Reproduction or translation of any part of this work beyond that
permitted by U.S. copyright laws without the written permission of Dell Inc. is unlawful and strictly forbidden.
September 2013 | Version 2 .0
iii Dell PowerEdge C410x Technical Guide
Table of contents
1 System overview ..................................................................................................................................................................5
New technologies ..............................................................................................................................................................5
System features ...................................................................................................................................................................5
Specifications ......................................................................................................................................................................5
Supported host servers ..................................................................................................................................................... 6
2 Chassis views and features ................................................................................................................................................ 7
Front panel view and features .......................................................................................................................................... 7
Back panel view and features ........................................................................................................................................... 7
System setup overview ..................................................................................................................................................... 8
Carrier sled modules and features 9..................................................................................................................................
Fan ....................................................................................................................................................................................... 11
3 PCIe card slots ................................................................................................................................................................... 12
GPGPU cards ..................................................................................................................................................................... 12
4 Power ..................................................................................................................................................................................14
Power supply units ...........................................................................................................................................................14
5 Rack information ............................................................................................................................................................... 15
6 Operating systems ............................................................................................................................................................ 16
Supported operating systems ......................................................................................................................................... 16
7 Systems management ...................................................................................................................................................... 17
PCIe- -node mapping management to .......................................................................................................................... 17
Embedded server management ..................................................................................................................................... 17
Firmware and drivers ........................................................................................................................................................18
Updati BMC firmwa ng re ..................................................................................................................................................18
8 GPGPU software ................................................................................................................................................................ 19
GPGPU technology uses ................................................................................................................................................. 19
Appendix A. Additional specifications and options ................................................................................................... 20
System dimensions .......................................................................................................................................................... 20
System weight .................................................................................................................................................................. 20
Environmental specifications .........................................................................................................................................21
Power supply specifications ........................................................................................................................................... 21
Appendix B. Standards compliance ............................................................................................................................. 22
Appendix C. Additional resources ................................................................................................................................. 23
Tables
Table 1. Technical specifications .......................................................................................................................................5
Table 2. PowerEdge C410x supported PowerEdge servers and features 1 ................................................................ 6
Table 3. Power supply efficiency .....................................................................................................................................14
Table 4. iPass port to PCIe device mapping .................................................................................................................. 17
Table 5. C410x chassis dimensions ................................................................................................................................ 20
Table 6. System weight ..................................................................................................................................................... 20
Table Environmental specifications 7. ............................................................................................................................ 21
Table 8. Power supply specifications .............................................................................................................................. 21
Table 9. Industry standard documents .......................................................................................................................... 22
Table 10. Additional resources .......................................................................................................................................... 23
Figures
Figure 1. Front panel: C410x expansion chassis .............................................................................................................. 7
Figure 2. Back panel: C410x expansion chassis .............................................................................................................. 8
Figure 3. PCIe HIC with external iPASS connector ......................................................................................................... 8


Product specificaties

Merk: Dell
Categorie: Server
Model: PowerEdge C410X

Heb je hulp nodig?

Als je hulp nodig hebt met Dell PowerEdge C410X stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Server Dell

Handleiding Server

Nieuwste handleidingen voor Server