OPERATION AND INSTALLATION
INSTRUCTIONS MANUAL
English
DUCTED AIR-CONDITIONING UNIT
(7.0-14.0kW)
Unit Model:
Indoor unit
FDM24PEVLK
FDM30PEVLK
FDM36PEVLK
FDM42PEVLK
FDM48PEVLK
FDYM24PEVLK
FDYM30PEVLK
FDYM36PEVLK
FDYM42PEVLK
FDYM48PEVLK
Outdoor unit
R24PEVLK
R30PEVLK
R36PEVLK
R42PETLK/R42PEYLK
R48PETLK/R48PEYLK
RY24PEVLK
RY30PEVLK
RY36PEVLK
RY42PETLK/RY42PEYLK
RY48PETLK/RY48PEYLK
User Notice




 Ensure unifi ed power supply for each indoor unit.




 Never install wired controller in wet place or under sunlight directly.




 Shielding twisted pair line must be adopted as signal line or wiring (communication) of
wired controller once the unit is installed in the place where there is electromagnetic
interference.




 Make sure communication line is connected into correct port to avoid communication




 Never knock, throw or frequently disassemble the wired controller.




 Never operate the wired controller with wet hand.
error.
English 1
Notes: The functions with * are reserved for other models and are not applicable for the models
listed in this manual.
Contents
I SAFETY PRECAUTIONS ....................................................................................................................... 2
II DISPLAYING PART ................................................................................................................................ 6
2.1 LCD Display of Wired Controller ........................................................................................................................................... 6
2.2 Instruction to LCD ............ ........................................................................................... ............................................ 7
III BUTTONS ............................................................................................................................................... 8
3.1 Silk Screen of Buttons ........................................................................................................................................................... 8
3.2 Instruction to Function of Buttons .......................................................................................................................................... 8
IV INSTALLATION OF WIRED CONTROLLER .......................................................................................... 9
V INSTRUCTION TO OPERATION .......................................................................................................... 10
5.1 On/Off .................................................................................................................................................................................. 10
5.2 Mode Setting ....................................................................................................................................................................... 10
5.3 Temperature Setting ............................................................................................................................................................ 11
5.4 Fan Speed Setting ............................................................................................................................................................... 11
5.5 Swing Control Function* ...................................................................................................................................................... 12
5.6 Timer Setting ....................................................................................................................................................................... 12
5.7 Air Exchange Setting* ......................................................................................................................................................... 14
5.8 Sleep Setting ....................................................................................................................................................................... 15
5.9 Turbo Function Setting ......................................................................................................................................................... 16
5.10 Save Function Setting ....................................................................................................................................................... 16
5.11 E-heater Setting* ............................................................................................................................................................... 18
5.12 Blow Function Setting ........................................................................................................................................................ 19
5.13 Quiet Function Setting ....................................................................................................................................................... 20
5.14 Field Setting ...................................................................................................................................................................... 20
5.15 Other Functions ................................................................................................................................................................. 21
VI ERROR DISPLAY ................................................................................................................................. 22
VII SETTING OF INDOOR ROOM SENSOR ............................................................................................. 23
7.1 Setting of Double Indoor Room Sensors ............................................................................................................................. 23
7.2 Fresh Air Control* ................................................................................................................................................................ 23
7.3 The head of delivery of the condensate drainage pump* .................................................................................................... 24
VIII DIMENSIONS OF INDOOR UNIT AND OUTDOOR UNIT ................................................................... 25
8.1 Dimensions of Indoor Unit ................................................................................................................................................... 25
8.2 Dimensions of Outdoor Unit ................................................................................................................................................ 26
IX INSTALLATION INSTRUCTIONS ........................................................................................................ 27
9.1 Precautions on Installation of Outdoor Unit ......................................................................................................................... 27
9.2 Precautions on Installation of Indoor Unit ............................................................................................................................ 27
9.3 Level Check of the Indoor Unit ............................................................................................................................................ 29
9.4 Installation of Rectangular Air Pipe ..................................................................................................................................... 29
9.5 Installation of Drainage Pipeline .......................................................................................................................................... 30
9.6 Testing of Drainage System ................................................................................................................................................. 30
9.7 Selection of the Refrigerant Pipe ......................................................................................................................................... 31
9.8 Connection of Pipe ..................................................................................................................................... 31
9.9 Installation of Protective Layer of the Refrigerant Pipe ....................................................................................................... 35
9.10 Position and Method of Installing Wired Controller ............................................................................................................ 36
9.11 Electric Installation ............................................................................................................................................................. 37
9.12 Cable Connecting Diagram ............................................................................................................................................... 41
9.13 Troubleshooting and Maintenance ..................................................................................................................................... 44
X SPECIFICATIONS ................................................................................................................................ 47
the Refrigerant
Display


Product specificaties

Merk: Daikin
Categorie: Airco
Model: RY24PEVLK

Heb je hulp nodig?

Als je hulp nodig hebt met Daikin RY24PEVLK stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Daikin

Handleiding Airco

Nieuwste handleidingen voor Airco