Pagina 1/33
Installer reference guide
R32 split series
RXM20A5V1B
RXM25A5V1B9
RXM35A5V1B9
RXM42A5V1B
ARXM25A5V1B
ARXM35A5V1B9
RXM50A5V1B8
ARXM50A5V1B8
RXP50N5V1B8
Table of contents
Installer reference guide
2
RXM-A(9)(8), ARXM-A(9)(8), RXP-N8
R32 split series
4P769827-4C – 2024.07
Table of contents
1 About the documentation 4
1.1 About this document...................................................................................................................................................... 4
1.1.1 Meaning of warnings and symbols................................................................................................................ 5
2 General safety precautions 7
2.1 For the installer .............................................................................................................................................................. 7
2.1.1 General........................................................................................................................................................... 7
2.1.2 Installation site............................................................................................................................................... 8
2.1.3 Refrigerant — in case of R410A or R32......................................................................................................... 11
2.1.4 Electrical......................................................................................................................................................... 12
3 Specific installer safety instructions 15
4 About the box 21
4.1 Outdoor unit................................................................................................................................................................... 21
4.1.1 To unpack the outdoor unit........................................................................................................................... 21
4.1.2 To handle the outdoor unit ........................................................................................................................... 21
4.1.3 To remove the accessories from the outdoor unit....................................................................................... 22
5 About the unit 23
5.1 Identification .................................................................................................................................................................. 23
5.1.1 Identification label: Outdoor unit.................................................................................................................. 23
6 Unit installation 24
6.1 Preparing the installation site ........................................................................................................................................ 24
6.1.1 Installation site requirements of the outdoor unit ....................................................................................... 25
6.1.2 Additional installation site requirements of the outdoor unit in cold climates ........................................... 27
6.2 Opening the unit ............................................................................................................................................................ 28
6.2.1 About opening the unit.................................................................................................................................. 28
6.2.2 To open the outdoor unit .............................................................................................................................. 28
6.3 Mounting the outdoor unit............................................................................................................................................ 28
6.3.1 About mounting the outdoor unit................................................................................................................. 28
6.3.2 Precautions when mounting the outdoor unit ............................................................................................. 29
6.3.3 To provide the installation structure............................................................................................................. 29
6.3.4 To install the outdoor unit............................................................................................................................. 30
6.3.5 To provide drainage....................................................................................................................................... 30
6.3.6 To prevent the outdoor unit from falling over.............................................................................................. 31
7 Piping installation 32
7.1 Preparing refrigerant piping........................................................................................................................................... 32
7.1.1 Refrigerant piping requirements ................................................................................................................... 32
7.1.2 Refrigerant piping insulation ......................................................................................................................... 33
7.1.3 Refrigerant piping length and height difference........................................................................................... 33
7.2 Connecting the refrigerant piping.................................................................................................................................. 33
7.2.1 About connecting the refrigerant piping ...................................................................................................... 34
7.2.2 Precautions when connecting the refrigerant piping ................................................................................... 34
7.2.3 Guidelines when connecting the refrigerant piping ..................................................................................... 35
7.2.4 Pipe bending guidelines................................................................................................................................. 36
7.2.5 To flare the pipe end ..................................................................................................................................... 36
7.2.6 Using the stop valve and service port ........................................................................................................... 37
7.2.7 To connect the refrigerant piping to the outdoor unit................................................................................. 38
7.3 Checking the refrigerant piping ..................................................................................................................................... 39
7.3.1 About checking the refrigerant piping .......................................................................................................... 39
7.3.2 Precautions when checking the refrigerant piping....................................................................................... 39
7.3.3 To check for leaks .......................................................................................................................................... 40
7.3.4 To perform vacuum drying ............................................................................................................................ 40
8 Charging refrigerant 42
8.1 About charging refrigerant............................................................................................................................................. 42
8.2 About the refrigerant ..................................................................................................................................................... 43
8.3 Precautions when charging refrigerant ......................................................................................................................... 44
8.4 To determine the additional refrigerant amount.......................................................................................................... 44
8.5 To determine the complete recharge amount.............................................................................................................. 44
8.6 To charge additional refrigerant.................................................................................................................................... 44
8.7 To check refrigerant piping joints for leaks after charging refrigerant......................................................................... 45
8.8 To fix the fluorinated greenhouse gases label............................................................................................................... 45
Table of contents
Installer reference guide
3
RXM-A(9)(8), ARXM-A(9)(8), RXP-N8
R32 split series
4P769827-4C – 2024.07
9 Electrical installation 46
9.1 About connecting the electrical wiring.......................................................................................................................... 46
9.1.1 Precautions when connecting the electrical wiring...................................................................................... 46
9.1.2 Guidelines when connecting the electrical wiring ........................................................................................ 47
9.1.3 Specifications of standard wiring components............................................................................................. 49
9.2 To connect the electrical wiring to the outdoor unit .................................................................................................... 49
10 Finishing the outdoor unit installation 51
10.1 To finish the outdoor unit installation ........................................................................................................................... 51
10.2 Closing the unit............................................................................................................................................................... 51
10.2.1 To close the outdoor unit.............................................................................................................................. 51
11 Configuration 52
11.1 Facility setting................................................................................................................................................................. 52
11.1.1 To set the facility mode ................................................................................................................................. 52
11.2 Standby electricity saving function................................................................................................................................ 52
11.2.1 About the standby electricity saving function .............................................................................................. 52
11.2.2 To turn ON standby electricity saving function............................................................................................. 53
12 Commissioning 54
12.1 Precautions when commissioning ................................................................................................................................. 54
12.2 Checklist before commissioning .................................................................................................................................... 54
12.3 Checklist during commissioning..................................................................................................................................... 55
12.4 To perform a test run ..................................................................................................................................................... 55
12.5 Starting up the outdoor unit.......................................................................................................................................... 56
13 Hand-over to the user 57
14 Maintenance and service 58
14.1 Overview: Maintenance and service.............................................................................................................................. 59
14.2 Maintenance safety precautions ................................................................................................................................... 59
14.3 Checklist for yearly maintenance of the outdoor unit .................................................................................................. 59
14.4 About the compressor ................................................................................................................................................... 59
15 Troubleshooting 61
15.1 Overview: Troubleshooting............................................................................................................................................ 61
15.2 Precautions when troubleshooting................................................................................................................................ 61
15.3 Solving problems based on symptoms .......................................................................................................................... 61
15.3.1 Symptom: Indoor units fall, vibrate or make noise....................................................................................... 61
15.3.2 Symptom: The unit is NOT heating or cooling as expected.......................................................................... 61
15.3.3 Symptom: Water leakage .............................................................................................................................. 62
15.3.4 Symptom: Electrical leakage.......................................................................................................................... 62
15.3.5 Symptom: Unit does NOT function or burn damage .................................................................................... 62
15.4 Fault diagnosis using LED on outdoor unit PCB............................................................................................................. 62
16 Disposal 63
16.1 Overview: Disposal......................................................................................................................................................... 63
16.2 To pump down ............................................................................................................................................................... 63
16.3 To start and stop forced cooling .................................................................................................................................... 64
16.3.1 To start and stop forced cooling using the indoor unit ON/OFF switch....................................................... 64
16.3.2 To start and stop forced cooling using the indoor unit user interface......................................................... 64
17 Technical data 65
17.1 Wiring diagram ............................................................................................................................................................... 65
17.1.1 Unified wiring diagram legend ...................................................................................................................... 65
17.2 Piping diagram................................................................................................................................................................ 67
17.2.1 Piping diagram: Outdoor unit........................................................................................................................ 67
18 Glossary 70